background image

4

Tornado Mini Use, Care, and Installation Guide

TO R N A D O   M I N I

I N S E R T

C O R E

Safety Information

Your safety and the safety of others are very important.

We have provided many important safety messages in this 

manual for your appliance. Always read and obey all safety 

messages.

This is the Safety Alert Symbol. This symbol alerts you to 

potential hazards that can cause severe bodily injury or death. 

All safety messages will follow the Safety Alert Symbol and either 

the words “

DANGER

” “

WARNING

” or “

CAUTION

DANGER

Danger means that failure to heed this safety statement may 

result in severe injury or death.

READ AND SAVE THESE INSTRUCTIONS

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a) Use this unit only in the manner intended by the 
manufacturer.  If you have questions, contact the manufacturer.

b) Before servicing or cleaning unit, switch power off at service 
panel and lock the service disconnecting means to prevent 
power from being switched on accidentally.  When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

General Safety

WARNING

Warning means that failure to heed this safety statement 

may result in extensive product damage, serious personal 

injury, or death.

CAUTION

Caution means that failure to heed this safety statement 

may result in minor or moderate personal injury, property or 

equipment damage.

WARNING

To reduce the risk of fire or electric shock, do not use this fan 

with any solid-state control device.

WARNING

CAUTION

For General Ventilating Use Only. Do Not Use To Exhaust 

Hazardous Or Explosive Materials And Vapors. Take care 

when using cleaning agents or detergents. Suitable for use in 

household cooking area. 

WARNING

WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE 
FIRE:

a)  Never leave surface units unattended at high settings. 
Boilovers cause smoking and greasy spillovers that may ignite.  
Heat oils slowly on low or medium settings.

b)  Always turn hood ON when cooking at high heat or 
when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambe’).

c)  Clean ventilating fans frequently.  Grease should not be 
allowed to accumulate on fan or filter.

d)  Use proper pan size.  Always use cookware appropriate for 
the size of the surface element.

Summary of Contents for Tornado Mini AK8400BS

Page 1: ...WWW ZEPHYRONLINE COM JAN21 0101 Tornado Mini AK8400BS AK8400BS290 EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 2: ...2 Tornado Mini Use Care and Installation Guide TORNADO MINI INSERT CORE...

Page 3: ...ructions 8 14 Ducting Calculation Sheet 8 Mounting Height Clearance Ducting 9 Ducting Options 10 Hood Speci cations 11 Electrical Supply 12 Grounding 12 Mounting the Hood 13 Ductless Recirculation 14...

Page 4: ...ot be locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive produ...

Page 5: ...in walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be...

Page 6: ...National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and...

Page 7: ...onduit and all installation tools Cable locking connector if required by local codes Stainless steel liner Recirculating kit ZRC 8400A Parts Supplied Quantity Part 1 Power pack hood 1 Aluminum mesh lt...

Page 8: ...Ft Ft Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent fe...

Page 9: ...bottom should be no less than 20 for electric cook tops and 24 for gas cook tops Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hood...

Page 10: ...ns with sheet metal screws and tape all joints w certi ed Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages...

Page 11: ...are and Installation Guide ZEPHYRONLINE COM Installation Instructions Top Side 20 9 16 10 5 8 3 1 4 1 5 16 19 1 2 12 1 8 11 3 7 16 6 5 1 16 1 5 8 9 15 16 1 3 16 9 11 16 10 3 16 Front 14 3 16 1 15 16 6...

Page 12: ...on product Grounding FIG A 28 Max GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escap...

Page 13: ...wood base NOTE Wood blocking may need to be added to cabinet base if additional support is needed See FIG D and FIG E 6 Remove 4 screws from Power Pack face plate The face plate will drop down and han...

Page 14: ...converted to be a recirculating hood a set of charcoal lters are required on top of its standard Metal Filter set Order according to its part number below The standard mesh lters are intended to captu...

Page 15: ...15 Tornado Mini Use Care and Installation Guide ZEPHYRONLINE COM Features Controls Slide Controls 0 I I I I I I Blower On O 1 2 0 I I I BLOWER ON OFF SPEED SELECTION LIGHTS OFF DIM BRIGHT 1 2...

Page 16: ...abrasive stainless steel polish cleaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth or micro ber cloth and buff in the direction of the stainles...

Page 17: ...4 1 AK8400BS290 50200054 1 To order parts visit us online at http store zephyronline com LumiLight LED In the unlikely event that your LumiLight LED fails please contact Zephyr to order replacement pa...

Page 18: ...18 Tornado Mini Use Care and Installation Guide TORNADO MINI INSERT CORE Wiring Diagram BODY MOTOR B W WHITE BLACK GREY B W GREEN RED BLACK B W YELLOW RED WHITE BLUE BROWN WIRING DIAGRAM...

Page 19: ...erate and shuts the blower down The blower will function properly after the thermally protected system cool down Damaged capacitor Change the capacitor The blower is defective possibly seized Change t...

Page 20: ...e hood within 20 electric cook tops or 24 gas cook tops and 36 range The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood Close all the wi...

Page 21: ...ries Description Part Number Replacement Parts LumiLight LED 6W Z0B0049 Aluminum Mesh Filter 50200054 Optional Accessories Recirculating Kit ZRC 8400A Replacement Charcoal Filter Z0F C084 Liner 30 AK0...

Page 22: ...22 Tornado Mini Use Care and Installation Guide TORNADO MINI INSERT CORE Notes...

Page 23: ...labor costs associated with this warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO...

Page 24: ...ake a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways tha...

Page 25: ...WWW ZEPHYRONLINE COM JAN21 0101 Tornado Mini AK8400BS AK8400BS290 EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation...

Page 26: ...2 Tornado Mini Guide d utilisation d entretien et d installation INS RER CORE TORNADO MINI...

Page 27: ...e calcul pour le conduit d a ration 8 Hauteur de montage d gagement et gaine 9 Options de conduits 10 Sp ci cations de la hotte 11 Fourniture lectrique 12 Mise la terre 12 Montage de la hotte 13 Recir...

Page 28: ...icant b Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle Lors...

Page 29: ...normes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de...

Page 30: ...que est ad quate et conforme au National Electrical Code ANSI NFPA 70 derni re dition ou aux normes CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 No 0 M91 derni re dition et tous les cod...

Page 31: ...ous les outils d installation Raccord de c ble si requis par les codes locaux Doublure en acier inoxydable Kit de recirculation ZRC 8400A Pi ces fournies Quantit Partie 1 Capot du bloc d alimentation...

Page 32: ...Nombre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air convenab...

Page 33: ...e de montage entre le haut de la cuisini re et le bas de la hotte ne doit pas tre inf rieure 20 po pour les tables de cuisson lectriques et 24 po pour les tables de cuisson au gaz Il est important d i...

Page 34: ...rgent ou du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout l chappeme...

Page 35: ...lation ZEPHYRONLINE COM Instructions d installation Haut C t 20 9 16 po 10 5 8 po 3 1 4 po 1 5 16 po 19 1 2 po 12 1 8 po 11 po 3 7 16 po 6 p o 5 1 16 po 1 5 8 po 9 15 16 po 1 3 16 po 9 11 16 po 10 3 1...

Page 36: ...trique l entr e de service avant le c blage ATTENTION Mise la terre CONSIGNES DE MISE LA TERRE Cet appareil doit tre mis la terre En cas de court circuit le l de mise la terre limite le risqu de choc...

Page 37: ...e les vis passeront par les trous de montage du bloc d alimentation puis la doublure et la base en bois REMARQUE Des blocs de bois peuvent devoir tre ajout s la base de l armoire si un support suppl...

Page 38: ...rculation Lorsqu il est converti en hotte recirculation un ensemble de ltres charbon est requis en plus de son ensemble de ltres m talliques standard Commandez selon son num ro de pi ce ci dessous Les...

Page 39: ...e Arr t Choix de Vitesse 1 Lumi res teindre Veilleuse Forte intensit 2 Ventilateur Marche Arr t Choix de Vitesse 0 l appareil est teint I quivaut la vitesse lente II la vitesse moyenne et III la vites...

Page 40: ...ilisez un produit de polissage nettoyant pour acier inoxydable non abrasif pour polir et polir le lustre et le grain de l acier inoxydable Frottez toujours l g rement avec un chiffon en coton propre o...

Page 41: ...ur commander des pi ces visitez nous en ligne http store zephyronline com LumiLight LED Dans le cas peu probable o votre LumiLight LED tombe en panne veuillez contacter Zephyr pour commander des pi ce...

Page 42: ...18 Tornado Mini Guide d utilisation d entretien et d installation INS RER CORE TORNADO MINI Sch ma de c blage CORPS MOTEUR N B BLANC NOIR GRIS N B VERT ROUGE NOIR N B JAUNE ROUGE BLANC BLEU MARRON 0...

Page 43: ...le ventilateur est trop chaud pour fonctionner et arr te le ventilateur Le ventilateur fonctionnera correctement apr s le refroidissement du syst me thermiquement prot g Condensateur endommag Changez...

Page 44: ...justez la distance entre la table de cuisson et le bas de la hotte moins de 20 plaques de cuisson lectriques ou 24 po plaques de cuisson gaz et 36 po Le vent provenant des fen tres ouvertes ou des por...

Page 45: ...cription Num ro d article Pi ces de rechange LumiLight LED 6 W Z0B0049 Filtre mailles en aluminium 50200054 Accessoires optionnels Kit de recirculation ZRC 8400A Filtre charbon de rechange Z0F C084 Do...

Page 46: ...22 Tornado Mini Guide d utilisation d entretien et d installation INS RER CORE TORNADO MINI Remarques...

Page 47: ...e for all labor costs associated with this warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLI...

Page 48: ...produit au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la co...

Reviews: