background image

13

T

roubleshooting

TROUBLESHOOTING PROCEDURES FOR SIENA WALL

Issue

Cause

What to do

After installation, 
the unit doesn’t 
work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.   The wires on the control board are loose.

3.   Make sure the wires on the control board are 

connected properly.

4.  The switch board and control board wirings are 

disconnected.

4.  Make sure the wirings between the switch 

board and control board are connected 
properly.

5.  The switch board or control board is defective.

5.  Change the switch board or control board.

Light works, but 
blower is not 
turning.

1.   The blower cable is disconnected.

1.   Check all wirings from the blower to be sure 

all cables are connected properly.

2.  The blower is defective, possibly seized.

2.  Change the blower.

3.  The thermally protected system detects if the 

blower is too hot to operate and shuts the blower 
down.

3.  The blower will function properly after the 

thermally protected system cool down.

4.  The switch board or control board is defective.

4.  Change defective part.

The unit is 
vibrating.

1.  The motor is not secure in place.

1.  Tighten the motor in place.

2.  Damaged blower wheel.

2.  Replace the blower.

3.  The hood is not secured in place.

3.  Check the installation of the hood.

The unit is 
whistling.

7KH¿OWHULVQRWLQWKHFRUUHFWSRVLWLRQ

$GMXVWWKH¿OWHUVXQWLOWKHZKLVWOLQJVWRSV

2.   The duct pipe connections are not sealed or 

connected properly.

2.   Check the duct pipe connections to be sure all 

connections are sealed properly.

The blower is 
working, but the 
lights are not.

1.  Defective bulb.

1.  Change the bulb.

2.  The bulb wire is loose.

2.  Check bulb wire connections at the control 

board and the light bulbs. Reconnect any 
loose wires.

The unit turns on 
by itself. 

1.   A spot light or kitchen lamp is shining directly 

onto the switch controls. 

1.   The switch controls are light sensative. A 

direct light source onto the switch controls 
may disrupt switch functions. 

The speed levels 
of the blower 
sound the same.

1.   Using the wrong size of ducting. 

1.   Change the ducting to at least 8” or higher.

The hood is 
not venting out 
properly.

1.  The hood might be hanging too high from the 

cook top.

1.  Adjust the distance between the cook top and 

the bottom of the hood within 26” and 34” 
range.

2.  The wind from the opened windows or opened 

doors in the surrounding area are affecting the 
ventilation of the hood.

2.  Close all the windows and doors to eliminate 

WKHRXWVLGHZLQGÀRZ

3.  Blockage in the duct opening or ductwork.

3.  Remove all the blocking from the duct work or 

duct opening.

4.  The direction of duct opening is against the wind.

4.  Adjust the duct opening direction.

5.  Using the wrong size of ducting.

5.  Change the ducting to at least 8” or higher.

Mesh Filter is 
vibrating.

 0HVK¿OWHULVORRVH

1.  Make sure the metal clips in the handle are 

QRWVWXFN2UUHSODFHWKHPHVK¿OWHU

2.   Filter spring clip is loose or broken.

8QLQVWDOODQGUHLQVWDOO¿OWHUSXVKXSRQ¿OWHU

ODWFK5HSODFHPHVK¿OWHULIQHHGHG

Summary of Contents for Siena ZSI-E30AS-ES

Page 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number MAR14 0201 2014 Zephyr Corporation Siena ZSI E30AS ES ZSI E36AS ES...

Page 2: ...www zephyronline com...

Page 3: ...5 Mounting Height Clearance 6 Ducting Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Range Hood 9 FEATURES CONTROLS ICON Touch Controls 10 MAINTENANCE Cleaning and Filter Care 11 Light Bulbs 12 TROUBLESH...

Page 4: ...are and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK...

Page 5: ...To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2...

Page 6: ...red by local codes Duct cover extension accessory HARDWARE PACKAGE CONTENTS MODELS ZSI E30AS ES ZSI E36AS ES PARTS SUPPLIED 1 Hood with internal blower 2 Baffle filters 1 Duct cover assembly top and b...

Page 7: ...1 Duct pieces T otal Equivalent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 F...

Page 8: ...I FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover exte...

Page 9: ...to the outside unless using the recirculating option Use single wall rigid Metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some...

Page 10: ...6SHFL FDWLRQV Top of Hood Side of Hood Front of Hood AC In C L 10 1 2 29 15 16 35 7 8 12 3 8 STANDARD min ducted 27 1 2 min recirc 32 max 42 Z1C 00SI min ducted 46 1 2 min recirc 50 1 2 max 79 8 7 16...

Page 11: ...to top of ERG RI KRRG E 0 DW VFUHZV DQJ KRRG RQWR VFUHZV DQG KDQG WLJKWHQ 8VH 0 VFUHZV WR IXUWKHU VHFXUH WKH KRRG WR WKH ZDOO from inside the hood on line B 10 Center and attach duct cover bracket to...

Page 12: ...Control Technology ACT allows the installer to set the maximum fan CFM to align with local codes and regulations To verify the maximum fan CFM With hood off hold the Button for two seconds If all five...

Page 13: ...y product containing chlorine bleach Do not use orange cleaners DI H LOWHUV 7KH EDI H OWHUV LQVWDOOHG E WKH IDFWRU DUH LQWHQGHG WR OWHU RXW UHVLGXH DQG JUHDVH IURP FRRNLQJ 7KH need not be replaced on...

Page 14: ...erious burns Make sure all power is turned off and bulbs are not hot Access light bulb by removing light bulb lens cover by 1 screw FIG B 5HPRYH E WXUQLQJ EXOE FRXQWHU FORFNZLVH 1RWH XOE GRHV QRW XQVF...

Page 15: ...RUUHFW SRVLWLRQ GMXVW WKH OWHUV XQWLO WKH ZKLVWOLQJ VWRSV 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connections to be sure all connections are sealed prope...

Page 16: ...am 21 16 5 9 7 9 VOLTS HZ MAX AMPS 120 60 1 2 ZSI E30AS ES ZSI E36AS ES CIRCUIT DIAGRAM USE ONLY 13W GU24 FLUORESCENT LIGHT BULBS MODEL SPS T3 13GUS 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW 0 EORZHU FRQ JX...

Page 17: ...acement Parts DI H LOWHU HDFK OXRUHVFHQW XOE 8 HDFK Optional Accessories Duct Cover Extension Kit Z1C 00SI To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 Li...

Page 18: ...rst year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SH...

Page 19: ...Guide d utilisation d entretien et d installation www zephyronline com Model number Serial Number MAR14 0201 2014 Zephyr Corporation Siena ZSI E30AS ES ZSI E36AS ES...

Page 20: ...www zephyronline com...

Page 21: ...et hauteur de montage 6 Options d installation pour le conduit 7 6SpFL FDWLRQV GH OD KRWWH 8 Montage de la hotte 9 COMMANDES ET CARACT RISTIQUES ICON Commandes 10 ENTRETIEN 1HWWR DJH HW HQWUHWLHQ GHV...

Page 22: ...pas la hotte sans surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R...

Page 23: ...plus r cente dition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien de l lectricit section 1 la plus r cente dition du code C22 2 No 0 M91 ainsi que tous les codes et r glements en vigu...

Page 24: ...t de conduit Accessoire recirculation d air CONTENU DE LA TROUSSE DE QUINCAILLERIE MOD LES ZSI E30AS ES ZSI E36AS ES PI CES FOURNIES 1 Hotte avec ventilateur interne 2 Filtres d flecteurs 1 Ensemble d...

Page 25: ...s 6 embout mural circ registre 30 pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude 90 15 pi x pi 7 or 10 7 or 10 circ coude 45 9 pi x pi pi pi pi 6 chapeau de toiture circ 30 pi x pi 7...

Page 26: ...isponibles consultez les exigences de hauteur d espace libre requise par le fabricant de la cuisini re ainsi que la hauteur recommand e de montage de la hotte au dessus de la surface de cuisson Inform...

Page 27: ...l option de recirculation d air ne soit utilis e N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban a...

Page 28: ...e la hotte C t de la hotte Devant de la hotte Entr e lec L C 10 1 2 29 15 16 35 7 8 12 3 8 STANDARD min avec conduit 27 1 2 min avec recirc d air 32 max 42 Z1C 00SI min avec conduit 46 1 2 min avec re...

Page 29: ...HPHQW rWUH XWLOLVpV PDLV YpUL H G DERUG OHV UpJOHPHQWDWLRQV ORFDOHV DYDQW G XWLOLVHU GH WHOV GLVSRVLWLIV H IDLW GH QH SDV XWLOLVHU GHV DQFUDJHV PXUDX HW GHV YLV FRQYHQDEOHV SRXU VRXWHQLU OH SRLGV GH O...

Page 30: ...ACT La technologie de contr le du d bit d air permet l installeur d ajuster la quantit maximale d vacuation de pi min du ventilateur afin de respecter les codes et r glements en vigueur Pour v rifier...

Page 31: ...nts nettoyants orange LOWUH Gp HFWHXUV HV OWUHV Gp HFWHXUV LQVWDOOpV SDU OH IDEULFDQW RQW SRXU IRQFWLRQ GH OWUHU OHV UpVLGXV HW OD JUDLVVH GH cuisson Ils ne n cessitent aucun remplacement sur une base...

Page 32: ...e sens contraire des aiguilles d une montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille RUVTX LO HVW GLI FLOH GH UHWLUHU OHV DPSRXOH...

Page 33: ...tuyaux ne sont pas bien scell s ou les conduits ne sont pas connect s ad quatement 9pUL H OHV MRLQWV GX FRQGXLW SRXU YRXV DVVXUHU TX LOV sont ad quatement scell s Le moteur fonctionne mais pas les lum...

Page 34: ...HZ MAX AMPS 120 60 1 2 ZSI E30AS ES ZSI E36AS ES Schema de Cablage UTILISERUNIQUEMENT 13W GU24 FLUORESCENT AMPOULES MODEL SPS T3 13GUS RQVRPPDWLRQ HQHUJHWLJXH DYHF OD FRQ JXUDWLRQ SDU GHIDXW GX YHQWLO...

Page 35: ...ODFHPHQW LOWUH Gp HFWHXU XQLWp PSRXOH RXUHVFHQWH GH 8 XQLWp FFHVVRLUHV RSWLRQQHOV Trousse de prolongement de recouvrement de conduit Z1C 00SI Pour commander des pi ces visitez notre site Web au http w...

Page 36: ...responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE R...