MODEL: CSH-ExxSX

NO DUCTING IS PROVIDED
EXTERNAL AND INTERNAL BLOWER SOLD SEPARATELY

Make sure to remove the protective film off of the hood before installation in order to make removal of the film
easie r. Be careful not to scrat ch the stainless steel while installing.

1 - Hood Body
2 - Baffle Filters (1 - 36” model)
4 - GU-10, 120V, 50W Halogen Bulbs
1 - Hood Door
2 - Telescopic Duct Covers
1 - Ceiling Mounting Bracket

1 - HARDWARE PACKET

7 - 2” wood screws
7 - anchors
7 - 1/2” washers
4 - screws (Dimension 5 x 15mm)
4 - adhesive fastener (to hold cable tie)
4 - cable tie

1 - HARDWARE PACKET, EXTERNAL BLOWER KIT

1 - 8” collar

1 - external blower connection box
10 - 1/2” self tapping screws
6 - 4mm internal diameter washer
1 - wiring for the connection to external blower

Summary of Contents for Shade CSH -E36SX

Page 1: ...Shade CSH E36SX CSH E42SX CSH E48SX Use Care and Installation Guide www zephyronline com Model number Serial number Date of Purchase Sales Dealer MAY07 0101 Zephyr Corporation...

Page 2: ...www zephyronline com...

Page 3: ...ounting Height and Clearance Ducting Specifications Internal Blower Preparing Hood for External Blower Mounting the Hood FEATURES CONTROLS Controls Overview Door Insert Panel MAINTENANCE Cleaning Ligh...

Page 4: ...DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate...

Page 5: ...while installing 1 Hood Body 2 Baffle Filters 1 36 model 4 GU 10 120V 50W Halogen Bulbs 1 Hood Door 2 Telescopic Duct Covers 1 Ceiling Mounting Bracket 1 HARDWARE PACKET 7 2 wood screws 7 anchors 7 1...

Page 6: ...nd straight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7...

Page 7: ...ble reduce the number or transitions and turns If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from openingas possible If turns or transitions are...

Page 8: ...External Blower External Blower WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside...

Page 9: ...35 7 16 41 7 32 47 1 4 20 10 or 24 10 12 DOOR INSERT PANEL 1 8 3 175 mm thickness 36 inch 31 5 6 42 inch 36 13 16 48 inch 42 7 8 24 5 8 625mm 8 8 12 16 7 8 31 1 4 9 3 16 6 1 5 O 8 5 16 8 1 4 R 2 3 1 1...

Page 10: ...shown using the provided 1 2 5x15mm screws with washers 3 P osition capacitor box as shown 4 Secure capacitor bo x to hood using the provided 1 2 self tapping screws ATTENTION The following are intru...

Page 11: ...finish installation of capacitor box Refer to Fig A on previous page 7 Attach short capacitor connector to blower connector 8 Attach long capacitor connector to control board connector 9 Use plastic t...

Page 12: ...on with external blower model CBE 1000 For instructions on installing internal blower model CBI 600 please turn to page 8 NOTE Please refer to the CBE 1000 manual for external blower mounting instruct...

Page 13: ...side hood 9 Attach grounding wire from external blower wiring box to grounding screw of the junction box Refer on Fig A in diagram below 10 Final view of external blower preparation Continue to page 1...

Page 14: ...er of the ceiling bracket to fit the 6 or 8 round duct work through Attach bracket to ceiling with 2 screws provided 7 Prepare duct work and electrical All Electrical work must be performed by a quali...

Page 15: ...IN PLACE BY SCREWING SCREWS WITH WASHERS THROUGH HOOD INTO THE WALL 4HERE ARE TWO HOLES AT THE BOTTOM INSIDE THE HOOD IN WHICH TO DO THIS 0LACE TELESCOPIC DUCT COVERS ON TOP OF HOOD AND EXTEND TOP DU...

Page 16: ...selected by presing to decrease and to increase speed level T he display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function...

Page 17: ...d with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting...

Page 18: ...located on the bottom of therange hood you can control the following features remotely Blower On Off By pressing the blower is switched On and Off When swi tched on the blower starts up on speed level...

Page 19: ...CSH E42SX 36 13 16 24 5 8 1 8 CSH E36SX 31 5 16 24 5 8 1 8 Removing and Installing Insert Panel 1 Using a Phillips head screwdriver remove 3 screws a from the top cap 2 Remove top cap b and slide fron...

Page 20: ...cleaners Baffle Filters The Metal Filters fitted by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are requiredto be kept clean...

Page 21: ...ff and bulbs are not hot Remove bulbby pressing both ends of the metal retainingclip together the light socket will now protudefrom the hood allowingyou to remove the bulb B e careful when releasing r...

Page 22: ...n of duct opening is against the wind 5 Using the wrong size of ducting 1 Baffle filter is loose 1 Control board needs to be reset 1 Defective control board 1 Make sure the circuit breaker and the uni...

Page 23: ...Part Halogen Bulb GU 10 120V 50W Z0B 0020 s e i r o s s e c c A d n a s t r a P f o t s i L Internal Blower 600 cfm CBI 600 External Blower 1000 cfm CBE 1000 Duct Cover Extension Kit Z1C 00SH Accesso...