5

Duct pieces 

Total

Equivalent number
length  x used      =

3- 1/ 4” x 10”
Rect.,
straight

1 Ft.           x (      )   =

Ft.    

8” Round,
straight

1 Ft.           x (      )   =

Ft.    

3- 1/ 4” x 10”
Rect. 90

0

elbow

15 Ft.         x (      )   =

Ft.    

3- 1/ 4” x 10”
Rect. 45

0

elbow

9 Ft.           x (      )   =

Ft.    

3- 1/ 4” x 10”
Rect. 90

0

flat elbow

24 Ft.         x (      )   =

Ft.    

3- 1/ 4” x 10”
Rect.
wall cap
with damper

30 Ft.         x (      )   =

Ft.    

3- 1/ 4” x 10”
Rect. to
6” round
transition

5 Ft.           x (      )   =

Ft.    

3- 1/ 4” x 10”
Rect. to
6” round
transition
90

0  

elbow

20 Ft.         x (      )   =

Ft.    

6” Round,
90

0  

elbow

15 Ft.         x (      )   =

Ft.    

6” Round,
45

0  

elbow

9 Ft.           x (      )   =

Ft.    

Ft.    

7” Round,
straight

1 Ft.           x (      )   =

Ft.    

Subtotal column 1  =

Duct pieces 

Total

Equivalent number
length  x used      =

6”- 8” Round
wall cap
with damper

30 Ft.         x (      )   =

Ft.    

Round

wall cap
with damper

30 Ft.         x (      )   =

Ft.    

7” or 8” 

Round,

90

0  

elbow

15 Ft.         x (      )   =

Ft.    

7” or 8” 

7” or 8” 

Round,

45

 

elbow

9 Ft.           x (      )   =

Ft.    

Ft.    

Ft.    

Ft.    

6”- 8” Round,
roof cap

30 Ft.         x (      )   =

Ft.    

7” or 8”

Round,

roof cap

30 Ft.         x (      )   =

Ft.    

Subtotal column 2  =

Subtotal column 1  =

Total ductwork      =

Maximum Duct  Length: 

For satisfactory air movement,

the total duct length of a 3 1/ 4” x 10” rectangular  6” or 7”
diameter round duct should not exceed 100 equivalent feet.

6” round to
3- 1/ 4” x 10”
rect. 
transition

1 Ft.           x (      )   =

Ft.    

6” round to
3- 1/ 4” x 10”
rect. 
transition
90

0  

elbow

16 Ft.         x (      )   =

Ft.    

7” round to
3 1/ 4” x 10”
rect. 
transition

8 Ft.           x (      )   =

Ft.    

7” round to
3- 1/ 4” x 10”
rect. 
transition
90

0  

elbow

23 Ft.         x (      )   =

Ft.    

Installation – 

Ducting Calculation Sheet

Summary of Contents for Roma Island ZRM-E36BS

Page 1: ...Use Care and Installation Guide Model number Serial Number www zephyronline com Roma Island ZRM E36BS ZRM E42BS ZRM E36BS290 ZRM E42BS290 JAN13 0301...

Page 2: ...www zephyronline com...

Page 3: ...ght Clearance 6 Ducting Options 7 Hood Speci cations 8 Mounting the Hood 9 10 Ductless Recirculating 11 FEATURES CONTROLS Electronic LED Controls 12 MAINTENANCE Hood and Filter Cleaning 13 Light Bulbs...

Page 4: ...te for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close tting lid cook...

Page 5: ...al installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and...

Page 6: ...6BS ZRM E42BS ZRM E36BS290 ZRM E42BS290 PARTS SUPPLIED HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Hack saw to cut down trim pieces Cable connector if requi...

Page 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Page 8: ...ose performance and ef ciency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any diffe...

Page 9: ...ed to the outside unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certi ed Silver Tape or Duct Tape...

Page 10: ...ine com Installation Hood Speci cation CL 35 7 8 41 7 8 14 3 15 16 26 15 16 STANDARD min ducted 28 min recirc 32 max 39 Z1C 01RM EXTENSION min ducted 50 1 2 min recirc 54 1 2 max 79 12 3 1 2 4 1 8 5 6...

Page 11: ...ord front on the top support frame faces the front of the hood where the controls will be located FIG D The key holes on the top support frame should cover the wood screws previously installed in the...

Page 12: ...x 1 4 screws FIG D2 9 Assemble Bottom Duct Covers together over top duct covers using the nal 6 M3 x 6 screws 3 screws on each side of the duct cover FIG D3 Bottom Duct Covers should rest on top of t...

Page 13: ...REQUIRED IF NO DUCTING IS USED Kit includes charcoal lters brackets and air diverter plate Hood Models Part No Filters Brackets in pkg ZRM E36BS ZRC 00RM 2 ZRM E42BS ZRC 01RM 3 1 Purchase recirculatin...

Page 14: ...If lights are on they will also switch off when this button is pressed These controls feature a memory function that will remember the last setting before being powered off For example If blower is o...

Page 15: ...on cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh lters installed by the factory are intended to lter out...

Page 16: ...ot hot Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are dif cult to turn due to prolonged use rmly attach the included glass suc...

Page 17: ...stallation of the hood The unit is whistling 1 The lter is not in the correct position 1 Adjust the lters 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connect...

Page 18: ...16 www zephyronline com Wiring Diagrams...

Page 19: ...20 Aluminum Mesh Filter each 50200038 Optional Accessories Recirculating Kit ZRM E36BS ZRC 00RM Recirculating Kit ZRM E42BS ZRC 01RM Replacement Charcoal Filter each Z0F C002 Extension Duct Cover Z1C...

Page 20: ...all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIA...

Page 21: ...Guide d utilisation d entretien et d installation www zephyronline com Num ro de mod le Num ro de s rie JAN13 0301 Zephyr Corporation Roma Island ZRM E36BS ZRM E42BS ZRM E36BS290 ZRM E42BS290...

Page 22: ...www zephyronline com...

Page 23: ...montage 6 Options d installation pour le conduit 7 Sp ci cations de la hotte 8 Montage de la hotte 9 10 Reprise d air sans conduit 11 COMMANDES Commandes lectroniques DEL 12 ENTRETIEN Nettoyage des lt...

Page 24: ...s surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R DUIRE LES RISQUE...

Page 25: ...en quali S assurer que l installation lectrique est ad quate et qu elle respecte le Code national de l lectricit la plus r cente dition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien d...

Page 26: ...Liste du mat riel 4 www zephyronline com...

Page 27: ...pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude 90 15 pi x pi 7 or 10 7 or 10 circ coude 45 9 pi x pi pi pi pi 6 chapeau de toiture circ 30 pi x pi 7 or 10 circ chapeau de toiture 30...

Page 28: ...pr senter des risques d incendie plus lev s tandis que les hottes install es trop hautes seront dif ciles atteindre et verront leur ef cacit et leur rendement r duits Si elles sont disponibles consult...

Page 29: ...ppements doivent tre dirig s l ext rieur de la maison moins que l option de reprise d air ne soit utilis e N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit a...

Page 30: ...8 www zephyronline com Installation Sp ci cations de la hotte...

Page 31: ...cadre de xation sup rieur l emplacement d sir au plafond l aide de quatre 4 rondelles et vis bois M4 x 1 1 2 Une vis devrait tre ajout e chaque coin pour xer le cadre de xation au plafond FIG A2 Le ca...

Page 32: ...r avant d assembler les pi ces de recouvrement de conduit Consultez la page 11 pour de plus amples d tails 8 Fixez les pi ces de recouvrement sup rieures au cadre de xation sup rieur l aide de 2 vis 3...

Page 33: ...mprend des ltres charbon des supports et un d ecteur d air Mod le de hotte Num ro de pi ce Filtres et supports par paquet ZRM E36BS ZRC 00RM 2 ZRM E42BS ZRC 01RM 3 1 Procurez vous l ensemble de repris...

Page 34: ...12 www zephyronline com Commandes Commandes lectroniques DEL...

Page 35: ...et dans le sens du grain N utilisez pas de produits blanchir au chlore ou d agents nettoyants orange Filtres tamis en aluminium Les ltres tamis en aluminium install s par le fabricant ont pour foncti...

Page 36: ...s d vissant dans le sens contraire des aiguilles d une montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille Lorsqu il est dif cile de...

Page 37: ...appareil vibre 1 Le moteur n est pas bien x en place 1 Fixez solidement le moteur en place 2 La roue du ventilateur est endommag e 2 Remplacez le ventilateur 3 La hotte n est pas bien x e en place 3...

Page 38: ...16 www zephyronline com Sch ma de c blage...

Page 39: ...00038 Accessoires optionnels Ensemble de reprise d air ZRM E36BS ZRC 00RM Ensemble de reprise d air ZRM E42BS ZRC 01RM Filtres charbon de remplacement chaque Z0F C002 Ensemble de prolongement de recou...

Page 40: ...main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GARANTIE...

Reviews: