background image

Use, Care, and Installation Guide

www.zephyronline.com

Model number: 

Serial Number: 

APR14.0201 © 2014 Zephyr Corporation

Ravenna

ZRV-E30AGC
ZRV-E30AGG
ZRV-M90AGC
ZRV-M90AGG

Summary of Contents for Ravenna ZRV-E30AGC

Page 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number APR14 0201 2014 Zephyr Corporation Ravenna ZRV E30AGC ZRV E30AGG ZRV M90AGC ZRV M90AGG...

Page 2: ...www zephyronline com...

Page 3: ...e 6 Ducting Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS ICON Touch Controls 11 12 MAINTENANCE Hood and Filter Cleaning 13 Light Bulbs 14 TROUBLE...

Page 4: ...are and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK...

Page 5: ...edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances I FRGHV SHUPLW DQG D VHSDUDWH JURXQG ZLUH LV XVHG LW LV UHFRPPHQ...

Page 6: ...accessory HARDWARE PACKAGE CONTENTS MODELS ZRV E30AGC ZRV M90AGG ZRV E30AGC ZRV M90AGG 1 Hood body with internal blower 1 Aluminum mesh filter 1 Duct cover assembly top and bottom 1 Duct cover wall b...

Page 7: ...1 Duct pieces T otal Equivalent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 F...

Page 8: ...SHUIRUPDQFH DQG HI FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any difference...

Page 9: ...ing option Use single wall rigid Metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Ducting Opti...

Page 10: ...FL FDWLRQV side of hood front of hood top of hood STANDARD min ducted 23 min recirc 27 1 2 max 42 1 2 Z1C 00RV min ducted 41 min recirc 46 max 80 10 9 16 20 1 2 10 3 8 23 15 16 16 9 16 29 15 16 35 3 1...

Page 11: ...minum duct tape Re install electrical junction box with cable lock and LQVWDOO WKH HOHFWULFDO 12 Power up hood and check for leaks around duct tape 3ODFH WHOHVFRSLF GXFW FRYHUV RQWR KRRG DQG H WHQG LQ...

Page 12: ...F NO DUCTING IS USED LW LQFOXGHV FKDUFRDO OWHUV DQG DLU GLYHUWHU SODWH Hood Model Part No Filters in Pkg ZRV E30AG ZRV M90AG ZRC 00RV 2 1 Purchase recirculating kit per the part number above 6HFXUH DL...

Page 13: ...ction is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan CFM to align with local codes and...

Page 14: ...bled if recirculating hood To enable Charcoal Filter Replacement Reminder With hood off hold button and button simultaneously for two seconds All LED indicators will illuminate for three seconds confi...

Page 15: ...ne bleach Do not use orange cleaners Aluminum Mesh Filters 7KH DOXPLQXP PHVK OWHUV LQVWDOOHG E WKH IDFWRU DUH LQWHQGHG WR OWHU RXW UHVLGXH DQG JUHDVH IURP cooking They need not be replaced on a regula...

Page 16: ...urned off and bulbs are not hot 5HPRYH E WXUQLQJ EXOE FRXQWHU FORFNZLVH 1RWH XOE GRHV QRW XQVFUHZ LW WXUQV GHJUHHV stops and falls out I EXOEV DUH GLI FXOW WR WXUQ GXH WR SURORQJHG XVH UPO DWWDFK WKH...

Page 17: ...W WKH OWHUV XQWLO WKH ZKLVWOLQJ VWRSV 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connections to be sure all connections are sealed properly The unit turns o...

Page 18: ...HOV RU 0 7KH XVDJH RI 7 PD QRW EH necessary for your installation Please check your local codes for CFM restrictions By default the maximum blower CFM is set to 600 7R YHULI LI RXU LQVWDOOHU HQDEOHG 7...

Page 19: ...17 Fan Curve Diagrams...

Page 20: ...MAX AMPS 120 60 5 USE ONLY TYPE MR16 GU10 50 W MAX HALOGEN LIGHT BULBS ZRV E30AGC ZRV M90AGC ZRV E30AGG ZRV M90AGG CIRCUIT DIAGRAM 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW 0 EORZHU FRQ JXUDWLRQ ACT 390 CFM...

Page 21: ...DORJHQ HDFK OXPLQXP 0HVK LOWHU HDFK Optional Accessories Recirculating Kit ZRC 00RV 5HSODFHPHQW KDUFRDO LOWHU HDFK Duct Cover Extension Z1C 00RV Universal Make Up Air Damper MUA006A To order parts vis...

Page 22: ...rst year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SH...

Page 23: ...Guide d utilisation d entretien et d installation www zephyronline com Model number Serial Number APR14 0201 2014 Zephyr Corporation Ravenna ZRV E30AGC ZRV E30AGG ZRV M90AGC ZRV M90AGG...

Page 24: ...www zephyronline com...

Page 25: ...le conduit 7 6SpFL FDWLRQV GH OD KRWWH 8 Montage de la hotte 9 Recirculation d air sans conduit 10 COMMANDES ET CARACT RISTIQUES ICON Commandes 11 12 ENTRETIEN 1HWWR DJH GH OD KRWWH HW GHV OWUHV 13 Am...

Page 26: ...pas la hotte sans surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R...

Page 27: ...du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien de l lectricit section 1 la plus r cente dition du code C22 2 No 0 M91 ainsi que tous les codes et r glements en vigueur 6L OHV FRGHV SHU...

Page 28: ...LA TROUSSE DE QUINCAILLERIE MOD LES ZRV E30AGC ZRV M90AGG ZRV E30AGC ZRV M90AGG 1 Hotte avec ventilateur interne 1 Filtre tamis en aluminium 1 Ensemble de recouvrement de conduit parties sup rieure e...

Page 29: ...s 6 embout mural circ registre 30 pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude 90 15 pi x pi 7 or 10 7 or 10 circ coude 45 9 pi x pi pi pi pi 6 chapeau de toiture circ 30 pi x pi 7...

Page 30: ...sont disponibles consultez les exigences de hauteur d espace libre requise par le fabricant de la cuisini re ainsi que la hauteur recommand e de montage de la hotte au dessus de la surface de cuisson...

Page 31: ...des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban adh sif en toile ou GX UXEDQ Up HFWHXU FHUWL p 4XHOTXHV RSWLRQV...

Page 32: ...ant de la hotte Dessus de la hotte STANDARD min avec conduit 23 min avec recirculation d air 27 1 2 max 42 1 2 Z1C 00RV min avec conduit 41 min avec recirculation d air 46 max 80 10 9 16 20 1 2 10 3 8...

Page 33: ...aux vis de montage et serrez les la main FIG 8WLOLVH OD GHUQLqUH YLV 0 SRXU HU SOXV VROLGHPHQW OD hotte au mur partir de l int rieur de la hotte FIG A 2 HQWUH HW H j O DLGH GH GHX YLV 0 OH VXSSRUW GH...

Page 34: ...UERQ HW XQ Gp HFWHXU G DLU 0RGqOH GH KRWWH 1XPpUR GH SLqFH LOWUHV SDU SDTXHW ZRV E30AG ZRV M90AG ZRC 00RV 2 1 Procurez vous l ensemble de recirculation d air en utilisant le num ro de pi ce ci dessus...

Page 35: ...d arr t retardement est en cours d utilisation pour teindre la hotte et annuler la fonction d arr t retardement V rification de la TCDA La technologie de contr le du d bit d air permet l installeur d...

Page 36: ...d faut doit tre activ lors de l utilisation du mode de recirculation d air Pour activer le rappel de remplacement des filtres charbon Lorsque la hotte est teinte tenez les touches et enfonc es simult...

Page 37: ...LV HQ DOXPLQLXP HV OWUHV j WDPLV HQ DOXPLQLXP LQVWDOOpV SDU OH IDEULFDQW RQW SRXU IRQFWLRQ GH OWUHU OHV UpVLGXV HW OD graisse de cuisson Ils ne n cessitent aucun remplacement sur une base r guli re ma...

Page 38: ...ans le sens contraire des aiguilles d une montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille RUVTX LO HVW GLI FLOH GH UHWLUHU OHV DP...

Page 39: ...2 Les joints des tuyaux ne sont pas bien scell s ou les conduits ne sont pas connect s ad quatement 9pUL H OHV MRLQWV GX FRQGXLW SRXU YRXV DVVXUHU TX LOV sont ad quatement scell s Le moteur fonctionne...

Page 40: ...s cubes par minute 3DU GpIDXW OH QRPEUH PD LPDO GH SL PLQ GX YHQWLODWHXU HVW GH 3RXU YpUL HU VL YRWUH LQVWDOODWHXU D DFWLYp OD 7 DSSX H VXU OD WRXFKH GH PLVH HQ PDUFKH HW WHQH la enfonc e pendant troi...

Page 41: ...17 LDJUDPPHV GHV FRXUEHV FDUDFWpULVWLTXHV GHV YHQWLODWHXUV...

Page 42: ...SEULEMENT DES AMPOULES HALOG NES MR16 GU10 50WMAX ZRV E30AGC ZRV M90AGC ZRV E30AGG ZRV M90AGG SCH MA DE CIRCUITS ORANGE ORANGE VENT VENT VENT LAMPE CA120V CONDENSATEUR CA ADAPT CA120V 60Hz BO TIER Mo...

Page 43: ...mis en aluminium unit 50200044 FFHVVRLUHV RSWLRQQHOV Trousse de recirculation d air ZRC 00RV Filtre charbon de remplacement unit Z0F C002 Trousse de prolongement de recouvrement de conduit Z1C 00RV Po...

Page 44: ...responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE R...

Reviews: