Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. 
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust 
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-
circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct 
work, if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option 
is not possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal  fi lters are required on top of its standard Metal 
Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture 
residue from cooking and the optional charcoal  fi lters help to purify fumes exhausted from cooking for re-
circulation.

RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)

Kit includes charcoal fi lters and air diverter plate.

Hood Model 

       Part No. 

       Filters in Pkg.

ZNA-M90S 

       ZRC-0060   

          3

ZNA-E42S 

       ZRC-0060   

          3

1.   Purchase recirculating kit per the part number above.

2.  Secure air diverter plate to top support frame. (FIG. F) Open 

sides of air diverter plate should face left and right and align 
with louver holes on the duct covers. Run 6” ducting from top 
of blower housing and secure to air diverter plate. See manual 
included with recirculating kit for more detailed instructions.

3.  Remove metal mesh fi lters from hood. Clip charcoal fi lters onto                                                                      

each charcoal fi lter bracket. (FIG. G) The brackets are pre-installed and 
located behind the mesh fi lters.

4.  Re-install metal mesh fi lters.

5. Enable 

charcoal 

fi lter change indicator on control panel. (Refer details 

to pg. 13)

6. Charcoal 

fi lters must be replaced after every 120 hours of use (or 

approximately every 3 to 4 months based on the average of 1 to 2 
hrs. of daily cooking time). The microprocessor in the controls when 
set, will elapse and count usage time and indicate when charcoal fi lter 
replacement is required every 120 hrs.

Charcoal Filter Replacements

Hood Model 

      Part No. 

  Qty to Order

ZNA-M90S 

      Z0F-C002 

          3

ZNA-E42S 

      Z0F-C002 

          3

Charcoal Filter Dimensions:
9in x 6 3/8in
228mm x 162mm

Installation – 

Ductless Recirculation

D

E

Install charcoal filter (plastic side exposed) 
into charcoal filter bracket.  Insert tab 
cut-out side D of charcoal filter into bracket 
first.  Lock charcoal filter into place by 
pushing down on side E with locking tabs.

front of the hood

back of the hood

FIG. F

FIG. G

Summary of Contents for Napoli Island ZNA-E42S

Page 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number MAR09 0102 Zephyr Corporation Napoli Island ZNA M90S ZNA E42S...

Page 2: ...www zephyronline com...

Page 3: ...lation Sheet 5 Mounting Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 10 Ductless Recirculation 11 CONTROLS 12 14 MAINTENANCE Hood and Filter Cleaning 15 Lights 16 TRO...

Page 4: ...NS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not...

Page 5: ...al installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and...

Page 6: ...support frame 1 Top duct cover 1 Bottom duct cover 1 Hood body 3 Metal mesh filters 4 50W GU 10 halogen lights 1 6 round damper pre installed MODELS ZNA M90S ZNA E42S PARTS SUPPLIED HARDWARE PACKAGE C...

Page 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Page 8: ...ill loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes fo...

Page 9: ...d to the outside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape...

Page 10: ...ifi cations 35 7 16 42 1065 900 Min 32 1 2 826 Max 49 1244 11 13 16 300 25 9 16 650 1 9 16 40 9 13 16 249 8 9 16 218 6 1 8 155 8 3 16 208 6 13 16 173 10 3 16 258 1 1 8 28 front of hood side of hood to...

Page 11: ...iling joist or stud blockings 3 Adjust height requirement and fasten support frames together NOTE If recirculating the hood install air diverter plate onto support frame 4 Slide upper and lower telesc...

Page 12: ...support with 4 screws Access the screws from inside the hood This will require at least two people Installation Mounting the Hood WARNING Electrical wiring must be done by a qualified person s in acc...

Page 13: ...per the part number above 2 Secure air diverter plate to top support frame FIG F Open sides of air diverter plate should face left and right and align with louver holes on the duct covers Run 6 ducti...

Page 14: ...ut down after 15 minutes 4 Lights On Dim Off Switch lights on by pressing once press a second time to dim and again to shut off lights 5 Display Window The display window indicates speed levels and fe...

Page 15: ...age time and indicate by a flashing when charcoal filter replacements are needed C Setting the Filter Change Reminder When off hold for approximately 5 seconds The display will change from exhaust mod...

Page 16: ...30 hours of use Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning Metal Filter Clean...

Page 17: ...al Filters The metal filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Filters...

Page 18: ...does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber l...

Page 19: ...The unit is vibrating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the ho...

Page 20: ...ach Z0B 0020 Metal Filter each 50200004 Optional Accessories Recirculating Kit ZRC 0060 Replacement Charcoal Filter each Z0F C002 Duct Cover Extension Z1C 00NA To order parts visit us online at http s...

Page 21: ...ll labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABL...

Reviews: