background image

14

Monsoon Connect Use, Care, and Installation Guide

M O N S O O N 

C O N N E CT

I N S E R T

C O R E

Installation Instructions

Preparation & Installation

At least two installers are required due to the 

weight and size of the liner.

CAUTION

1.  Remove all packing materials and protective 

film prior to installation. Use caution during 
installation to prevent scratches or damage to 
the stainless steel. Remove safety screw on top 
of hood body.

2.  Cut out an opening in the bottom of the 

cabinet by following the dimensions in FIG. B.  

3.  Prepare liner for installation into cabinet by 

following the steps on page 15-16 for vertical 
ducting and 17-19 for horizontal ducting and 
20-22 for dual blower installation, if desired.

4.  Lift liner into bottom opening of cabinet and 

secure to interior of cabinet using (8) #8 x 1/2” 
stainless steel screws; (4) screws in the front 
and (4) screws in the sides. FIG. C.  

28-3/8” or 

34-

3/8” or 40

-3/8” or 46-

1/4”

 19

-3/

8”

cut o

ut

(AK9

42

8)

(AK94

34)

(AK9446

)

(AK9440

)

1/4 po

1-

1/8

 po

Make sure the surface you are securing the liner 

to is capable of holding the weight of AK94.  

Failure to do so may cause personal injury or 

damage to cooking surface or counter.

WARNING

FIG. B

FIG. C

5.  If using RF remote control, remove the light panel by (5) screws and extend the blue antenna wire. 

There is no need to secure it. Reinstall light panel.

6.  Finalize installation of electrical and duct work. Seal duct work with certified aluminum duct tape.  

Power on liner, check for leaks around duct tape and verify proper operation. 

NOTE:

 If access to top of liner is not available after installation, electrical and duct work connection 

may need to be made prior to installing the liner. 

7.  Re-install the previously removed bottom panel, side spacer panels (if  applicable), grease tray, 

and baffle filters.

Summary of Contents for Monsoon Connect

Page 1: ...WW ZEPHYRONLINE COM DEC20 0201 Air ow Control Technology TM C Monsoon Connect AK9428BS AK9434BS AK9440BS AK9446BS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installatio...

Page 2: ...2 Monsoon Connect Use Care and Installation Guide MONSOON CONNECT INSERT CORE...

Page 3: ...g 9 10 Ducting Options 11 Hood Speci cations 12 Electrical Supply 13 Cable Lock 13 Preparation Installation 14 16 Horizontal Ducting Preparation 17 19 PBD 1300B Dual Blower Installation 20 22 Features...

Page 4: ...annot be locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in extensive pr...

Page 5: ...thin walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must b...

Page 6: ...and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Dia...

Page 7: ...led 4 LumiLight LED 6W pre installed AK9446BS only 1 Single blower motor pre installed 1 8 round adapter with damper 2 Horizontal ducting blower mount brackets 1 Top rectangular cover plate 1 Hardware...

Page 8: ...x Ft Ft Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equivalent...

Page 9: ...9 Monsoon Connect Use Care and Installation Guide ZEPHYRONLINE COM Installation Instructions Mounting Height Clearance Ducting 24 min 34 max 36...

Page 10: ...nimum mount height between range top to hood bottom should be no less than 24 Maximum mount height should be no higher than 34 It is important to install the hood at the proper mounting height Hoods m...

Page 11: ...ti ed Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust must be ducted to the outside unless us...

Page 12: ...3 16 48 17 7 8 30 only 5 9 16 36 42 48 6 1 8 C L 30 9 1 4 36 11 7 8 42 14 7 8 48 17 7 8 2 elec k o 10 3 8 elec k o C L 5 1 2 7 11 16 12 19 3 8 12 3 remote antenna 7 11 16 9 15 16 9 1 2 14 3 16 8 1 16...

Page 13: ...n cord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an individua...

Page 14: ...8 8 x 1 2 stainless steel screws 4 screws in the front and 4 screws in the sides FIG C 28 3 8 or 34 3 8 or 40 3 8 or 46 1 4 19 3 8 cut out AK9428 AK9434 AK9446 AK9440 1 4 po 1 1 8 po Make sure the su...

Page 15: ...tion 1 Remove baffle lters by 1 Pulling lter toward front of liner 2 Pivoting rear of lter down 2 Remove grease tray by 1 Pulling up on tray to release from bottom panel 2 Lifting tray out of liner bo...

Page 16: ...m Panel Screws 2 1 4 Remove bottom panel by 1 Removing 2 screws from left and right sides of bottom panel 2 Pulling bottom panel toward front of liner to release from locking tabs 6 Vertical ducting p...

Page 17: ...ntal Ducting Preparation 1 Follow steps 1 to 4 from pages 15 and 16 Remove blower molex plug 2 Remove blower from liner by removing the 4 3 16 x 3 8 screws from the top of the liner Set screws aside f...

Page 18: ...ner secure plate to top of liner with 2 3 16 x 3 8 screws At this point install the liner into the cabinet by following the steps on page 14 step 4 After liner installation continue on page 18 5 From...

Page 19: ...ated on the interior back wall of the liner 2 Pivot top horizontal ducting bracket to meet captive nuts on interior back wall 1 2 1 8 Secure blower to captive nuts on interior back wall of liner with...

Page 20: ...the instructions below PBD 1300B dual blower kit compatible only with AK9434BS AK9440BS and AK9446BS 1 Remove the baffle lters and if applicable remove the side panels Disconnect blower plug 2 Remove...

Page 21: ...l previously removed blower onto one side of dual blower plate and attach by 4 previously removed screws from step 2 6 Install blower from PBD 1300B kit onto other side of dual blower plate by 4 3 16...

Page 22: ...al blower K and white single pin power cord F to dual blower PCB NOTE To secure the 10 transition adapter to top of hood a cut out of 14 1 2 width x 10 1 2 depth will need to be made in the cabinet bo...

Page 23: ...until the fan and lights are turned off CONTROL ICONS Power Press the power icon to power on or off the fan and lights The hood has a memory function to remember the last used settings for the fan and...

Page 24: ...TED or WIFI DISCONNECTED will appear on the LCD display whenever the connection changes which will be managed via the Zephyr Connect app While the fan is on press and hold for 3 seconds to enable the...

Page 25: ...ovides the option to reset the reminder Recirculating Mode Charcoal Filter Replacement Reminder Hold and for 3 seconds to enable or disable recirculating mode which will remind you to replace the char...

Page 26: ...ct information The Zephyr Connect app is available on iOS devices using iOS 11 0 or later or Android devices using Android version 8 or later Visit the Apple App Store or Google Play Store for more in...

Page 27: ...Start Enable Hood Name Delay Off Timer Enable delay off timer for 10 minutes After 10 minutes the hood will power off Alexa Stop Disable Hood Name Delay Off Timer Disable delay off timer Control Type...

Page 28: ...ause undesired operation Synchronization To create a unique link between your hood and remote control please follow these steps 1 With hood off press and hold on the hood until the controls display RE...

Page 29: ...utlet for easy storage Note The remote holder does not charge the RF remote Maximum remote control communication distance is 15 feet from the liner RF Remote Maintenance Clean the remote control using...

Page 30: ...eaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth or micro ber cloth and buff in the direction of the stainless steel grain The lters are intend...

Page 31: ...es 2 Pivot back of lter upwards so it is angled in the liner 3 Push lter into channel on back of liner to lock into place Removing the Grease Tray Grease tray has a hooked lip that attaches to bottom...

Page 32: ...ontact Zephyr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED Removal FIG H 1 Remove baffle lters 2 Remove light panel by ve screws 3...

Page 33: ...ering on the hood the CFM cannot be changed again CAUTION Some local codes limit the maximum amount of CFM a range hood can move ACT allows you to control the maximum blower CFM of select Zephyr Venti...

Page 34: ...lation 4 Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location To verify if your inst...

Page 35: ...ble Remove both spacer panels by 2 screws for each spacer panel 3 Remove 5 screws attaching light panel FIG I 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 Jumper 7 8 DEFAULT POSITIO...

Page 36: ...agram WIFI WHITE B W BLACK BLACK BLACK BLACK BLACK BLACK BLACK B W WHITE WHITE WHITE WHITE WHITE GREEN BODY MOTOR 1 MOTOR 2 WHITE K Single Blower Dual Blower A Wi Fi connection wire C Power wire for e...

Page 37: ...W BLACK BLACK BLACK BLACK BLACK BLACK BLACK B W WHITE WHITE WHITE WHITE WHITE GREEN BODY MOTOR 1 MOTOR 2 WHITE K Single Blower Dual Blower A Wi Fi connection wire B LED PCB wire C Power wire for expa...

Page 38: ...the blower is too hot to operate and shuts the blower down The blower will function properly after the thermally protected system cool down Damaged capacitor Change the capacitor Blower molex plug pin...

Page 39: ...ge the lter Spring clip is broken on the lter Change the spring clip RF Remote control does not work Battery is dead Replace battery with type A23 12v Poor communication with the hood Remote control m...

Page 40: ...cking the pathway to the range hood Walls may reduce signal strength User cannot change Wi Fi connections The range hood and user s phone have already connected Enter Bluetooth settings and forget the...

Page 41: ...e ZEPHYRONLINE COM List of Parts Accessories Description Part Number Replacement Parts LumiLight LED 6W Z0B0047 Baffle Filter each 50210039 Optional Accessories RF Remote Control 14000005 To order par...

Page 42: ...42 Monsoon Connect Use Care and Installation Guide MONSOON CONNECT INSERT CORE Notes...

Page 43: ...l labor costs associated with this warranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION T...

Page 44: ...e take a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways...

Page 45: ...WW ZEPHYRONLINE COM DEC20 0201 Air ow Control Technology TM C EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation Monsoon Connect AK9428BS AK9434BS AK9440BS AK9446B...

Page 46: ...2 Monsoon Connect Guide d utilisation d entretien et d installation INS RER CORE MONSOON CONNECT...

Page 47: ...Options de conduits 11 Sp ci cations de la hotte 12 Fourniture lectrique 13 Raccord de c ble 13 Pr paration et installation 14 16 Pr paration des conduits horizontaux 17 19 Installation du double ven...

Page 48: ...abricant b Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidentelle L...

Page 49: ...t normes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e de...

Page 50: ...te une alimentation lectrique de 120 V 60 Hz et est connect un circuit de d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blag...

Page 51: ...s par les codes locaux T l commande RF Moteur double soufflante Pi ces fournies Quantit Partie 1 Ins rer le corps de la hotte 2 Filtres chicane 3 Filtres chicane AK9446BS uniquement 2 LumiLight LED 6...

Page 52: ...r x Nombre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air conve...

Page 53: ...9 Monsoon Connect Guide d utilisation d entretien et d installation ZEPHYRONLINE COM Instructions d installation Hauteur de montage d gagement et gaine 24 po min 34 po max 36 po...

Page 54: ...re les deux La hauteur de montage minimale entre le haut de la cuisini re et le bas de la hotte ne doit pas tre inf rieure 24 po La hauteur de montage maximale ne doit pas d passer 34 po Il est import...

Page 55: ...e d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout l chappement doit tre canalis vers l ext...

Page 56: ...L C 30 po 9 1 4 po 36 po 11 7 8 po 42 po 14 7 8 po 48 po 17 7 8 po 2 po entr e defoncable 10 3 8 po entr e defoncable L C 5 1 2 po 7 11 16 po 12 po 19 3 8 po 12po 3 po antenne distance 7 11 16 po 9 15...

Page 57: ...d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 ls avec terre Veuillez galement vous r f rer au sch ma lectr...

Page 58: ...4 vis l avant et 4 vis sur les c t s FIG C 28 3 8 po 34 3 8 po 40 3 8 po 46 1 4 po 19 3 8 po coup AK9428 AK9434 AK9446 AK9440 1 4 po 1 1 8 po Assurez vous que la surface sur laquelle vous xez la doubl...

Page 59: ...ecteurs en 1 Tirant le ltre vers l avant de la doublure 2 Pivotement de l arri re du ltre vers le bas 2 Retirez le plateau graisse en 1 Tirant sur le plateau pour le d gager du panneau inf rieur 2 So...

Page 60: ...irez le panneau inf rieur en 1 Retirez les 2 vis des c t s gauche et droit du panneau inf rieur 2 Tirer le panneau inf rieur vers l avant de la doublure pour le d gager des languettes de verrouillage...

Page 61: ...taux 1 Suivez les tapes 1 4 des pages 15 et 16 Retirez le bouchon molex du ventilateur 2 Retirez le ventilateur de la gaine en retirant les 4 vis 3 16 x 3 8 du haut de la gaine Mettez les vis de c t p...

Page 62: ...ec 2 vis 3 16 x 3 8 ce stade installez la doublure ce stade installez la doublure dans l armoire en suivant les dans l armoire en suivant les tapes de la page 14 tape tapes de la page 14 tape 4 Apr s...

Page 63: ...l sup rieur pour qu il rencontre les crous captifs sur la paroi arri re int rieure 1 2 1 8 Fixez le ventilateur aux crous captifs sur la paroi arri re int rieure du rev tement avec 8 vis 3 16 x 3 8 4...

Page 64: ...oufflante PBD 1300B compatible uniquement avec AK9434BS AK9440BS ou AK9446BS 1 Retirez les ltres d ecteurs et le cas ch ant retirez les panneaux lat raux D branchez la che du ventilateur 2 Retirez les...

Page 65: ...c t de la plaque de ventilateur double et xez le l aide des 4 vis pr c demment retir es de l tape 2 6 Installez le ventilateur du kit PBD 1300B sur l autre c t de la plaque de ventilateur double l aid...

Page 66: ...t le cordon d alimentation blanc une broche F au PCB double ventilateur REMARQUE Pour xer l adaptateur de transition de 10 po au haut de la hotte une d coupe de 14 1 2 po de largeur x 10 1 2 po de pro...

Page 67: ...es ic nes ne dispara tront pas tant que le ventilateur et les lumi res ne seront pas teints IC NES DE CONTR LE Allumer Appuyez sur l ic ne d alimentation pour allumer ou teindre le ventilateur et les...

Page 68: ...IFI DISCONNECTED appara tront sur l cran LCD chaque fois que la connexion change ce qui sera g r via l application Zephyr Connect Retard automatique d sactiv Pendant que le ventilateur est en marche m...

Page 69: ...cation Zephyr Connect offre la possibilit de r initialiser le rappel Maintenez et pendant 3 secondes pour activer ou d sactiver le mode de recirculation qui vous rappellera de remplacer le ltre charbo...

Page 70: ...it L application Zephyr Connect est disponible sur les appareils iOS utilisant iOS 11 0 ou version ult rieure ou les appareils Android utilisant la version Android 8 ou ult rieure Visitez l Apple App...

Page 71: ...Start Enable Hood Name Delay Off Timer Activer la minuterie d arr t pendant 10 minutes Apr s 10 minutes la hotte s teint Alexa Stop Disable Hood Name Delay Off Timer D sactiver le temporisateur d arr...

Page 72: ...e et la t l commande veuillez suivre ces tapes 1 Avec le capot teint appuyez et maintenez sur le capot jusqu ce que les commandes affichent REMOTE PAIRING 2 Appuyez sur un bouton de la t l commande et...

Page 73: ...e Remarque le support de t l commande ne charge pas la t l commande RF La distance de communication maximale de la t l commande est de 15 pieds de la doublure Maintenance distance RF Nettoyez la t l c...

Page 74: ...non abrasif pour polir et polir le lustre et le grain de l acier inoxydable Frottez toujours l g rement avec un chiffon en coton propre ou en micro bres et polissez dans le sens du grain de l acier in...

Page 75: ...ter l arri re du ltre vers le haut pour qu il soit inclin dans la doublure 3 Poussez le ltre dans le canal l arri re de la doublure pour le verrouiller en place Retrait du bac graisse Le plateau grais...

Page 76: ...pi ces de rechange Voir la page de la liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es Retrait de la LED LumiLight FIG H 1 Retirer les ltres d ecteurs 2 Retirez le panneau...

Page 77: ...ng AVERTISSEMENT Technologie de contr le du d bit d air ACT Certains codes locaux limitent la quantit maximale de CFM qu une hotte de cuisini re peut d placer ACT vous permet de contr ler le CFM maxim...

Page 78: ...uivez l installation de la hotte 4 Retirez l autocollant CFM en aluminium appropri inclus avec la documentation de la hotte et placez le l int rieur du corps de la hotte sous le sch ma de c blage ou u...

Page 79: ...t par 2 vis pour chaque panneau d espacement 3 Retirez les 5 vis xant le panneau lumineux FIG I 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 Cavalier 7 8 POSITION PAR D FAUT 1 3 5 7...

Page 80: ...NOIR NOIR BLANC NOIR BLANC BLANC BLANC BLANC BLANC VERT CORPS MOTEUR 1 MOTEUR 2 BLANC K Souffleur simple Double ventilateur A Fil de connexion Wi Fi C C ble d alimentation pour PCB d extension D C ble...

Page 81: ...NC BLANC BLANC BLANC BLANC VERT CORPS MOTEUR 1 MOTEUR 2 BLANC K Souffleur simple Double ventilateur A Fil de connexion Wi Fi B Fil de carte PCB de LED C C ble d alimentation pour PCB d extension D C b...

Page 82: ...ventilateur Le ventilateur fonctionnera correctement apr s le refroidissement du syst me thermiquement prot g Condensateur endommag Changez le condensateur La broche de la prise molex du ventilateur...

Page 83: ...ltre Changer le clip ressort La t l commande RF ne fonctionne pas La batterie est morte Remplacez la batterie par un type A23 12v Mauvaise communication avec la hotte La t l commande doit tre moins de...

Page 84: ...ent r duire la puissance du signal L utilisateur ne peut pas modi er les connexions Wi Fi La hotte et le t l phone de l utilisateur sont d j connect s Entrez les param tres Bluetooth et oubliez l appa...

Page 85: ...ONLINE COM Liste des pi ces et accessoires La description Num ro d article Pi ces de rechange LumiLight LED 6 W Z0B0047 Filtre chicane chacun 50210039 Accessoires optionnels T l commande RF 14000005 P...

Page 86: ...42 Monsoon Connect Guide d utilisation d entretien et d installation INS RER CORE MONSOON CONNECT Remarques...

Page 87: ...is de d placement du technicien votre domicile pour que le Produit soit r par enlev ou r install Un an apr s la date d achat originale du Produit vous tes galement responsable de tous les frais de mai...

Page 88: ...lle produit au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il assure la...