background image

Important Safety Notice

READ AND SAVE THESE INSTRUCTIONS

2

www.zephyronline.com

WARNING 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. 

WARNING 

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

a.  Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. 
b.  Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.  

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service 
panel. 

CAUTION 

For general ventilating use only. Do not use to exhaust hazardous or explosive materials  and vapors.  Take care when using cleaning 
agents or detergents. Suitable for use in household cooking area. 

WARNING 

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE: 

a.  Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly 

on low or medium settings. 

b.  Always turn hood ON when cooking at high heat or when fl aming food   
c.  Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or fi lter. 
d.  Use proper pan size.  Always use cookware appropriate for the size of the surface element. 
e. Keep fan, fi lters and grease laden surfaces clean. 
f.  Use high setting on hood only when necessary. 
g.  Don’t leave hood unattended when cooking. 
h.  Always use cookware and utensils appropriate for the type of and amount of food being prepared. 

WARNING 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING: 

a.  SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. 

If the fl ames do not go out  immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  

b.  NEVER PICK UP A FLAMING PAN – You may be burned.  
c.  DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d.  Use an extinguisher ONLY if:

1.  You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fi re is small and contained in the area where it started.
3. The fi re department is being called.
4. You can fi ght the fi re with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.  Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards. 

Including fi re-rated construction.

b. Suffi cient air is needed for power combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent 

back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National 
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and 
the local code authorities.

c.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d.  Ducted fans must always vent to the outdoors.
e.  If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI 

(Ground Fault Interrupter protected branch circuit).

g.  NEVER place a switch where it can be reached from a tub or shower.
h.  Make sure the power is off before installing, wiring or maintenancing.

Summary of Contents for Milano Wall ZMI-M90AG

Page 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number FEB09 0201 Zephyr Corporation Milano Wall ZMI M90AS ZMI M90AG ...

Page 2: ...www zephyronline com ...

Page 3: ...ing Options 7 Hood Specifications 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Touch Controls 11 Charcoal Filter Replace Reminder 12 Metal Mesh Filter Clean Reminder 13 MAINTENANCE Hood and Filter Cleaning 14 Lights 15 TROUBLESHOOTING 16 LIST OF PARTS AND ACCESSORIES 17 Table of Contents ...

Page 4: ...ONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d...

Page 5: ...al installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe...

Page 6: ...codes Duct cover extension accessory Z1C 00MI Recirculating kit accessory ZRC 0040 HARDWARE PACKAGE CONTENTS MODELS ZMI M90AS ZMI M90AG 1 Suction Cup 1 Hood body with internal blower 2 Metal mesh filters 1 Duct cover assembly top and bottom 1 Duct cover wall bracket 2 50W GU 10 halogen light bulbs 1 6 round damper pre installed 1 Hardware package 1 Canopy glass or stainless steel PARTS SUPPLIED ...

Page 7: ...lent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangul...

Page 8: ...f available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Minimum Mounting Height Ducted 7 7 Hood mounted 28 above cooking surface 64 from floor Minimum Mounting Height Recirculating 7 10 Hood mounted 28 above cooking surface 64 from floor Maxmimum Mounting Height 10 1 Hood mounted...

Page 9: ...ing option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating side wall cap w gravity damper blower housing blower housing blower housing blower housing ...

Page 10: ...8 www zephyronline com Installation Hood Specifi cations 23 15 16 min ducted 26 1 2 min recirc 30 max 49 10 1 2 elec k o 4 8 1 2 35 7 16 14 20 1 2 6 Ø top of hood front of hood side of hood ...

Page 11: ... just below the ceiling or soffit using 2 M4 x 1 screws 10 Install electrical and duct work Seal duct work with aluminum duct tape 11 Power up hood and check for leaks around duct tape 12 Place telescopic duct covers onto hood and extend inner top duct cover upwards and secure to duct cover bracket using 2 M3 5 x 8 screws Secure bottom duct cover to hood body by also using 2 M3 5 x 8 screws If usi...

Page 12: ...e recirculating kit per the part number above 2 Secure air diverter plate to wall below duct cover bracket FIG B Run 6 ducting from top of hood and secure to air diverter plate See manual included with recirculating kit for more detailed instructions 3 Remove metal mesh filters from hood Clip charcoal filters onto each charcoal filter bracket FIG C The brackets are pre installed and located beind ...

Page 13: ... after 15 minutes 4 Lights On Dim Off Switch lights on by pressing once press a second time to dim and again to shut off lights 5 Display Window The display window indicates speed levels and features such as metal filter clean reminder delay off and charcoal filter change reminder Metal Filter Clean Reminder metal mesh filter After every 30 hours of use the display will start flashing an reminding...

Page 14: ...nd count usage time and indicate by a flashing when charcoal filter replacements are needed C Setting the Filter Change Reminder When off hold for approximately 5 seconds The display will change from exhaust mode to recirculating mode this indicates that the elapse timer function is switched on and charcoal filters are used Filter Replace Indicator When the display starts flashing the charcoal fil...

Page 15: ...of use Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning Metal Filter Clean Indicator When flashes on display the metal filters installed are required to be cleaned This will occur after every 30 hours of use Re setting Function Reset the filter clean reminder timer when filters are cl...

Page 16: ...se from cooking They need not be replaced on a regular basis but are required to be kept clean After 30 hours of use the letter A will flash on the control screen indicating time to clean the metal mesh filters Refer to instructions on page 13 on how to reset the indicator Filters may need to be cleaned more depending on cooking habits Remove and clean by hand or in dishwasher on low heat Spray de...

Page 17: ...not hot Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For Zephyr ...

Page 18: ...ective part The unit is vibrating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood 4 The switch board or control board is defective 4 Change defective part The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb i...

Page 19: ...ht Bulb GU 10 50W each Z0B 0020 Metal Mesh Filter each 50200011 Optional Accessories Recirculating Kit ZRC 0040 Replacement Charcoal Filter Z0F C002 Duct Cover Extension Z1C 00MI To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 ...

Page 20: ...all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIE...

Reviews: