TROUBLESHOOTING PROCEDURES FOR MONSOON I

Issue

Cause

What to do

After installation, 
the unit doesn’t 
work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.  The switch board and control board wires are 

disconnected.

3.  Make sure the wires between the switch board 

and control board are connected properly.

4.  The wires on control board are loose.

4.  Make sure the wires on the control board are 

connected properly.

5.  The switch board or control board is defective.

5.  Change the switch board or control board.

Light works, but 
blower is not 
turning.

1.  The blower wire is not connected. 

1.  Make sure the blower wire is plugged into the 

molex connector. 

2.  The thermally protected system detects if the 

blower is too hot to operate and shuts the blower 
down.

2.  The blower will function properly after the 

thermally protected system cool down.

3.  Damaged capacitor.

3.  Change the capacitor.

4.   Blower molex plug pin is not making contact.

4.   Disconnect the blower molex plug, check pins 

inside plug to see if pin is pushed inside the 
plug too far. Reseat pin if needed.

5.  The blower is defective, possibly seized. 

5.  Change the blower. 

The unit is 
vibrating.

1.  The blower is not secure in place.

1.  Tighten the blower in place.

2.  The liner is not secured in place. 

2.  Check the installation of the liner.

3.  Damaged blower wheel.

3.  Change the blower.

The unit is 
whistling.

1.   A fi lter is not in the correct position.

1.   Adjust the fi lters until the whistling stops.

2.   The duct pipe connections are not sealed or 

connected properly.

2.   Check the duct pipe connections to be sure all 

connections are sealed properly.

The blower is 
working, but the 
lights are not.

1.  The light bulb is loose.

1.  Tighten the bulb and make sure it’s secure.

2.  Defective halogen bulb.

2.  Change the halogen bulb.

3.  The light bulb plug is disconnected.

3.  Connect the light bulb plug.

The hood is 
not venting out 
properly.

1.  The hood might be hanging too high from the 

cook top.

1.  Adjust the distance between the cook top and 

the bottom of the hood within 26” and 36” 
range.

2.  Wind from an opened window or opened 

doors in the surrounding area are affecting the 
ventilation of the hood.

2.  Close all the windows and doors to eliminate 

outside wind fl ow.

3.  Blockage in the duct opening or duct work.

3.  Remove all the blocking from the duct work or 

duct opening.

4.  The direction of duct opening is against the wind.

4.  Adjust the duct opening direction.

5.  Using the wrong size of ducting.

5.  Change the ducting to correct size.

Filter is vibrating.

1.  Filter is loose.

1.  Adjust or change the fi lter.

2.  Spring clip is broken on the fi lter.

2.  Change the spring clip.

RF Remote 
control does not 
work

1.  Battery is dead.

1.  Replace battery with type A23 12v.

2.  Poor communication with the liner.

2.  Remote control must be within 15 ft of liner.

3.  RF remote lost communication with the liner.

3.  Reset liner and remote by switching power 

off at the circuit breaker for 5 minutes. Place 
remote on counter top near the liner and 
switch the circuit breaker back on.

T

roubleshooting

Summary of Contents for ESSENTIALS Monsoon I AK9228AS290

Page 1: ...stallation Guide www zephyronline com Model number Serial Number Date of Purchase Sales Dealer MAR12 0201 2012 Zephyr Ventilation Monsoon I AK9228AS AK9234AS AK9228AS290 AK9234AS290 READ AND SAVE THES...

Page 2: ...www zephyronline com...

Page 3: ...s 8 Electrical 9 Cabinet Preparation Installation 10 Vertical Ducting Preparation 11 Horizontal Ducting Preparation 12 14 FEATURES CONTROLS Touch Controls 15 16 RF Remote Control 17 MAINTENANCE Cleani...

Page 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Page 5: ...ircuit National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 This appliance requires a 120V 60Hz...

Page 6: ...1 8 round adaptor w damper 1 3 1 4 x 10 rectangular adaptor w damper 2 Horizontal ducting blower mount brackets 1 Top rectangular cover plate 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SU...

Page 7: ...Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15...

Page 8: ...igher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and...

Page 9: ...igid metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gr...

Page 10: ...nstallation Specifi cations Top View 3 4 View Back View 28 3 8 34 3 8 12 12 3 22 3 8 28 3 8 19 1 4 28 14 1 4 34 17 1 4 5 5 8 1 1 2 C L 7 3 4 28 9 1 4 34 12 1 4 2 elec k o 10 3 4 28 9 1 4 34 12 1 4 9 7...

Page 11: ...ing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere ci...

Page 12: ...rews in the sides FIG 3 WARNING Make sure the surface you are securing the liner to is capable of holding the weight of AK92 Failure to do so may cause personal injury or damage to cooking surface or...

Page 13: ...panels by removing 2 screws from behind each panel Installation Vertical Ducting Preparation 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 Remove bottom panel by 1 Removing 2 screws from left and...

Page 14: ...ide spacer panels by removing 2 screws from behind each panel 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 1 4 Remove bottom panel by 1 Removing 2 screws from left and right sides of bottom panel 2 Pu...

Page 15: ...inside the liner secure plate to top of liner with 2 3 16 x 3 8 screws A A B C C B 8 Remove knock outs A and B for rectangular ducting Remove knock outs B and C for round ducting Rect ducting Round du...

Page 16: ...e Plug in blower molex plug Horizontal ducting preparation is now Horizontal ducting preparation is now complete Refer to Page 10 Step 5 to complete Refer to Page 10 Step 5 to complete installation co...

Page 17: ...s levels selected 3 Delay Off This feature is used for programmed shut down of blower 5 minutes after the function is activated Press once a dot flashes in the lower right side of display indicating t...

Page 18: ...se Reset the filter clean reminder timer after filters are cleaned and re installed With hood off press and hold for approximately 5 seconds until on display disappears The filter clean reminder funct...

Page 19: ...sy storage The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder FIG 4 The remote holder can be inserted into a standard electrical outlet for easy storag...

Page 20: ...dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using hood Installing the Baffle Filters FIG 6 1 Place filter into top groove of the liner as shown and pull towa...

Page 21: ...g bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the glass suction cup provided to the bulb...

Page 22: ...d blower wheel 3 Change the blower The unit is whistling 1 A filter is not in the correct position 1 Adjust the filters until the whistling stops 2 The duct pipe connections are not sealed or connecte...

Page 23: ...tlet Diameter 8in 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675 700 725 750 Flow rate CFM THERMALLY PROTE...

Page 24: ...5 0 50 0 55 0 60 0 65 0 70 Pressure inAq Blower Fan Curve Model AK92 290 Monsoon I AC Input 120V 60Hz Outlet Diameter 8in 0 00 0 05 0 10 0 15 0 20 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150...

Page 25: ...5W each Z0B 0023 AK9228AS AK9234AS Baffle Filter Large each 50210013 AK9234AS Baffle Filter Small each 50210017 RF Remote Control 14000005 To order parts visit us online at http store zephyronline com...

Page 26: ...all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIA...

Page 27: ...ntretien et d installation www zephyronline com Num ro de mod le Num ro de s rie Date d achat D taillant MAR12 0201 Zephyr Corporation Monsoon I AK9228AS AK9234AS AK9228AS290 AK9234AS290 LISEZ ET CONS...

Page 28: ...www zephyronline com...

Page 29: ...lectricit 9 Pr paration et installation des armoires 10 Pr paration pour conduit vertical 11 Pr paration pour conduit horizontal 12 14 COMMANDES Commandes effleurement 15 16 Commande distance RF 17 EN...

Page 30: ...ns surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R DUIRE LES RISQU...

Page 31: ...cheminement du fil est ad quat N effectuez pas la mise la terre un tuyau de gaz Demandez un lectricien qualifi si vous n tes pas certain que la hotte a t mise la terre ad quatement N introduisez aucun...

Page 32: ...Adaptateur rectangulaire de 3 1 4 x 10 avec registre 2 Supports de montage pour ventilateur avec conduit horizontal 1 Plaque sup rieure rectangulaire 1 Trousse de quincaillerie CONTENU DE LA TROUSSE D...

Page 33: ...colonne 1 Pi ces de conduit Total Longueur x Nombre utilis 6 embout mural circ registre 30 pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude 90 15 pi x pi 7 or 10 7 or 10 circ coude 45...

Page 34: ...r 36 Il est important d installer la hotte la hauteur de montage ad quate Les hottes install es trop basses pourraient tre endommag es par la chaleur en plus de pr senter des risques d incendie plus l...

Page 35: ...ez toutes les pi ces du conduit avec des vis t le et isolez tous les joints avec du ruban adh sif en toile ou du ruban r flecteur certifi Quelques options pour le conduit d a ration Installation Optio...

Page 36: ...p cifi cations de la hotte Vue de haut Vue 3 4 Vue arri re 28 3 8 34 3 8 12 12 3 22 3 8 28 3 8 19 1 4 28 14 1 4 34 17 1 4 5 5 8 1 1 2 L C 7 3 4 28 9 1 4 34 12 1 4 2 Entr e d fon able 10 3 4 28 9 1 4 3...

Page 37: ...en vigueur Alimentation lectrique Cet appareil requiert une alimentation lectrique de 120V 60 Hz Il doit tre connect un circuit terminal individuel d ment mis la terre prot g par un disjoncteur de cir...

Page 38: ...nir le poids de la hotte AK92 sans quoi une personne pourrait se blesser ou la surface de cuisson ou le comptoir pourraient tre endommag s 5 Terminez l installation des composantes lectriques et du co...

Page 39: ...rieur vers l avant du bo tier pour le lib rer des languettes de verrouillage 6 La pr paration pour l installation verticale du conduit est termin e Retournez l tape 4 de la page 10 pour terminer l in...

Page 40: ...bo tier pour le lib rer des languettes de verrouillage 6 Enlevez le ventilateur du bo tier en retirant les 4 vis 3 16 x 3 8 de la partie sup rieure du bo tier Gardez les vis de c t pour une utilisati...

Page 41: ...artir de l int rieur l aide des 2 vis 3 16 x 3 8 A A B C C B 8 Enlevez les entr es d fon ables A et B pour installer un conduit rectangulaire Enlevez les entr es d fon ables B et C pour installer un c...

Page 42: ...hez le connecteur Molex La pr paration pour l installation La pr paration pour l installation verticale du conduit est termin e verticale du conduit est termin e Retournez l tape 5 de la page 10 Retou...

Page 43: ...pour programmer l arr t automatique du ventilateur et des lumi res 5 minutes apr s son activation Lorsque vous appuyez une fois sur un point clignote dans la partie inf rieure droite de l afficheur p...

Page 44: ...ur de nettoyage des filtres avec la hotte hors tension Lorsque la hotte est teinte appuyez environ 5 secondes sur la touche jusqu ce que l ic ne dis paraisse La fonction de rappel de nettoyage des fil...

Page 45: ...o lectrique est munie d un aimant pour un entreposage facile La commande peut tre mise sur n importe quelle surface magn tique comme un r frig rateur ou le support commande Zephyr FIG 4 Le support com...

Page 46: ...e l eau chaude savonneuse S chez les filtres et r installez les avant d utiliser la hotte Installation des filtres d flecteurs FIG 6 1 Placez le filtre vis vis de l entaille sup rieure comme illustr e...

Page 47: ...contraire des aiguilles d une montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille Lorsqu il est difficile de retirer les ampoules ap...

Page 48: ...ion de la hotte 3 L3 La roue du ventilateur est endommag e 3 Remplacez le ventilateur L appareil met un sifflement 1 L un des filtres est mal plac 1 Ajustez les filtres jusqu ce que le sifflement cess...

Page 49: ...5 600 625 650 675 700 725 750 D bit pi3 min Prot g thermiquement Ventilateur 410W Lampe Max 35Wx2 Total Max 480W 3 9A Tension 120V 60Hz AK9234AS Consommation d nergie Mod le AK9228AS w p bu g y r br b...

Page 50: ...0 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 Debit pi3 min Prot g thermiquement Ventilateur 82W Lampe Max 35Wx2 Total Max 152W 1 3A Tension 120V 60Hz AK9234AS290 Conso...

Page 51: ...r pour AK9228AS AK9234AS grand chaque 50210013 Filtre d flecteur pour AK9234AS petit chaque 50210017 Commande distance RF 14000005 Pour commander des pi ces visitez nous en ligne au www zephyronline c...

Page 52: ...main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GARANTIE...

Reviews: