PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit

GB  page

2

F  page

25

E  page

49

APPROVED FOR RESIDENTIAL APPLIANCES

FOR RESIDENTIAL USE ONLY

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for Elica Concave ECO-M90AS

Page 1: ...JAN06 0101...

Page 2: ...ave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Page 3: ...ed 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Description of the hood...

Page 4: ...Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Page 5: ...l local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed m...

Page 6: ...uide Control Ball with molex plug 6x70 screws x 4 to fix Duct cover brackets 10x60 wall anchors x 4 to fix Duct cover brackets 5 x 45 screws x 3 2 to fix Lower support bracket 1 for securing hood 2 9x...

Page 7: ...inet Side Cabinet 35 7 16 min cabinets opening widths 24 to 32 bottom of canopy to cooking surface ceiling CenterLine 11 1 2 23 1 4 13 3 8 Ducting and conduit area passage Duct bends are not considere...

Page 8: ...it Minimum Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed...

Page 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Page 10: ...studs otherwise proceed as follows Cutout drywall along marked lines Install each necessary between studs firmly flush with already existing stud front Make sure all mounting screws will anchor to ad...

Page 11: ...f the blower unit inside 15 Hang the blower unit housing with the 2 mounting hooks WARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in...

Page 12: ...IN YOUR HOME ELECTRICAL SYSTEM AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Facing the front of the range hood remove the left knockou...

Page 13: ...serves to hang the decorative panel Use pins 2 upper fixing screws and 1 at the bottom to fix the decorative panel Check that panel is firmly fixed on its position Rear View Installation 21 Fit contro...

Page 14: ...ilter housing electronic box and cables are acces sible Note temporarily fix the duct covers to inte gral ventilator housing with two screws FRONT VIEW REAR VIEW Rails location Duct covers Integral mo...

Page 15: ...stall upper duct cover to its upper support with 2 screws 1 per side Note Upper Duct Cover may be placed upside down to hide or unhide ventless slots 27 Check all light bulbs to make sure they are sec...

Page 16: ...on of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Vapour screen 6 Duct cover 7 Air outlet used for Ductless version only...

Page 17: ...on The control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the extraction mode and no charcoal filter is fitted In this case perform the signal re...

Page 18: ...e cooker hood s Control Ball flashes green orange red in sequence then replace the battery Remote Control Maintenance Clean the remote control using non abrasive detergents Follow the instructions bel...

Page 19: ...nth using non aggressive detergents either by hand or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly...

Page 20: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Page 21: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Page 22: ...uctless conversion kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm EBI 600A EBN 1100A ZRC 00CS Z0F C060 Part Description Part halogen bulb 12V...

Page 23: ...2 3 www zephyronline com Exploded View Diagram...

Page 24: ...2 4 Part Numbers...