background image

T

roubleshooting

16

www.zephyronline.com

TROUBLESHOOTING PROCEDURES FOR CYPRESS

Issue

Cause

What to do

After installation, 
the unit doesn’t 
work.

1.  The power source is not turned ON.

1.  Make sure the circuit breaker and the unit’s 

power is ON.

2.  The power line and the cable locking connector 

is not connecting properly.

2.  Check the power connection with the unit is 

connected properly.

3.  The switch board and control board wirings are 

disconnected.

3.  Make sure the wirings between the switch 

board and control board are connected 
properly.

4.  The wires on control board are loose.

4.  Make sure the wires on the control board are 

connected properly.

5.  The switch board or control board is defective.

5.  Change the switch board or control board.

Light works, 
but motor is not 
turning.

1.  The motor is defective, possible seized.

1.  Change the motor.

2.  The thermally protected system detects if the 

motor is too hot to operate and shuts the motor 
down.

2.  The motor will function properly after the 

thermally protected system cool down.

3.  Damaged capacitor.

3.  Change the capacitor.

4.  The motor wire is not connected.

4.  Make sure the motor wire is plugged into the 

molex connector.

The unit is 
vibrating.

1.  The motor is not secure in place.

1.  Tighten the motor in place.

2.  Damaged blower wheel.

2.  Change the blower.

3.  The hood is not secured in place.

3.  Check the installation of the hood.

The motor is 
working, but the 
lights are not.

1.  Defective halogen bulb.

1.  Change the halogen bulb.

2.  The light bulb is loose.

2.  Tighten the light bulb.

3.  The wires on the control board are loose.

3.  Make sure the wires on control board are 

connected properly.

The hood is 
not venting out 
properly.

1.  The hood might be hanging to high from the 

cook top.

1.  Adjust the distance between the cook top and 

the bottom of the hood within 26” and 36” 
range.

2.  The wind from the opened windows or opened 

doors in the surrounding area are affecting the 
ventilation of the hood.

2.  Close all the windows and doors to eliminate 

the outside wind fl ow.

3.  Blockage in the duct opening or duct work.

3.  Remove all the blocking from the duct work or 

duct opening.

4.  The direction of duct opening is against the wind.

4.  Adjust the duct opening direction.

5.  Using the wrong size of ducting.

5.  Change the ducting to correct size.

Heat lamp is not 
working.

1.  Toggle switch is not in the on position.

1.  Make sure the heat lamp power is ON.

2.  Heat lamp bulb is defective.

2.  Change the heat lamp bulb.

3.  Heat lamp bulb is loose.

3.  Tighten the heat lamp bulb.

Metal fi lter is 
vibrating.

1. Metal 

fi lter is loose.

1.  Change the metal fi lter.

2.  Spring clip is broken.

2.  Change the spring clip.

Summary of Contents for Cypress AK7836ASX

Page 1: ...e www zephyronline com Model number Serial Number Date of Purchase Sales Dealer AUG08 0101 Zephyr Corporation Cypress AK7836ASX AK7842ASX AK7848ASX READ AND SAVE THESE INSTRUCTIONS INTENDED FOR OUTDOO...

Page 2: ...www zephyronline com...

Page 3: ...ce 6 Ducting Options 7 Specifications 8 Electrical 9 Mounting the Range Hood 10 Single and Dual Internal Blowers 11 Remote Blower Preparation 12 FEATURES CONTROLS Touch Controls 13 MAINTENANCE Cleanin...

Page 4: ...ount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray...

Page 5: ...n Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determin...

Page 6: ...ne blower 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Single Internal Blower CBI 600B Dual Int...

Page 7: ...Ft 6 Round straight 1 Ft x Ft Subtotal column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15...

Page 8: ...transitions are required install as far away from hood duct output and as far apart between the two as possible Minimum mount height between range top to hood bottom should be no less than 30 Maximum...

Page 9: ...e ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Opt...

Page 10: ...ons 35 15 16 36 41 15 16 42 47 15 16 48 12 10 27 4 18 1 1 8 8 9 16 13 3 16 2 5 16 6 7 16 2 2 1 16 CL 5 9 16 ext blwr k o elec k o 2 11 16 top side front 4 5 16 10 transition used with dual external an...

Page 11: ...120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also...

Page 12: ...7836ASX 34 x 3 4 x 4 AK7842ASX 40 x 3 4 x 4 AK7848ASX 46 x 3 4 x 4 5 Hang hood on wood board and secure using 4 M4 x 16 screws NOTE Due to the weight of this hood ensure that the wood strip is attache...

Page 13: ...ctured is a PBI 1100A 2 Connect male end of blower wire to female plug in the hood plug is located inside the hood behind the control panel 3 Single Blower Connect 6 round duct work to blower collar D...

Page 14: ...clockwise 4 Connect 6 pin male connector from external blower wiring to 6 pin female connector on control board wire inside hood Secure green ground wire from external blower wiring to ground screw o...

Page 15: ...is off Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two Lights On Off Adjust Blower Level 2 Speeds 1 1 2 2 Switching the rocker switch to middle...

Page 16: ...ed to trap residue and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be place...

Page 17: ...bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diamet...

Page 18: ...secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the lights are...

Page 19: ...0B Dual Internal Blower PBI 1100A External Blower CBE 1000 In Line Blower PBN 1000A Vinyl Cover 36 AK0636AB Vinyl Cover 42 AK0642AB Vinyl Cover 48 AK0648AB 12 Duct Cover 36 AK0736AS 12 Duct Cover 42 A...