![Zephyr ALU-E43BSX Use, Care And Installation Manual Download Page 14](http://html1.mh-extra.com/html/zephyr/alu-e43bsx/alu-e43bsx_use-care-and-installation-manual_3660032014.webp)
- 14 -
CONTROLS
7
Clean Filters Indicator
- After 120 hours of fan usage, the clean fitlers indicator will turn on and the two side LED light strips
will flash on and off indicating it is time to clean the mesh filters.
-
To Reset with Hood Controls:
With hood off: hold the button for three seconds. The clean filters
indicator will turn off confirming the 120 hour timer has been reset.
8
Lights Indicator
- When lights are on high, medium or low, lights indicator will illuminate.
- After 240 hours of fan usage, the clean fitlers indicator will turn on and all LED light strips will flash on and
off indicating it is time to replace the charcoal filters.
-
To Reset with Hood Controls:
With hood off: hold the button for three seconds. The clean filters indicator
will turn off confirming the 240 hour timer has been reset.
- To Enable Charcoal Filter Replace Indicator:
With hood off: press and hold the button and button simultaneously for three seconds. All LED
indicators will illuminate for three seconds confirming function enabled.
- To Disable Charcoal Filter Replace Indicator:
With hood off: press and hold the button and button simultaneously for three seconds. All LED
indicators will blink two times confirming function disabled.
Mesh Filter Clean Reminder (always enabled)
Charcoal Filter Replace Reminder (disabled by default, must be enabled if recirculating hood)
-
To Reset with Remote Controls:
With hood off: hold the Blower On/Speed Selection button and Lights
button simultaneously.
-
To Reset with Remote Controls:
With hood off: press and hold the Delay Off button and the Lights button
simultaneously.