Important Safety Notice

3

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

CAUTION

To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,

attics, crawl spaces or garages.

OPERATION

Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers 

and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, 

maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to 

negligence and the warranty of the unit automatically expires due to improper maintenance.

*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.

ELECTRICAL REQUIREMENTS

Important:

Observe all governing codes and ordinances.
It is the customer’s responsibility:

-  To contact a qualified electrical installer.

-  To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 

latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and 

all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the 

ground path is adequate.
Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure the range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269

 

** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit 

protected by a 15 or 20 ampere circuit breaker or time delay fuse.  Wiring must be 2 wire with ground.  Please also refer to 

Electrical Diagram on product.

A cable locking connector (not supplied) might also be required by local codes.  Check with local requirements, purchase 

and install appropriate connector if necessary.

INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA. 

SUITABLE FOR USE IN DAMP LOCATIONS WHEN INSTALLED IN A 

GFCI PROTECTED BRANCH-CIRCUIT.

Cancer and Reproductive Harm - www.P65Warnings.ca.gov

WARNING

Prop. 65 Warning for California Residents

Summary of Contents for AK9834AS

Page 1: ...w zephyronline com Model number Serial Number Date of Purchase Sales Dealer APR19 0301 Zephyr Ventilation LLC Spruce AK9834AS AK9840AS AK9846AS AK9858AS READ AND SAVE THESE INSTRUCTIONS INTENDED FOR O...

Page 2: ...www zephyronline com...

Page 3: ...nce 6 Ducting Options 7 Specifications 8 Electrical 9 Installing the One Piece Insert 10 Insert Preparation 11 FEATURES CONTROLS Rotary Controls 12 MAINTENANCE Cleaning Installing Filters 13 Lights Pa...

Page 4: ...nattended when cooking h Always use cookware and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE...

Page 5: ...latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is r...

Page 6: ...9858AS 4 Halogen light bulbs pre installed 1 Dual internal blower pre installed 1 10 round duct collar 1 Hardware package HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installat...

Page 7: ...0 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3...

Page 8: ...e no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to rea...

Page 9: ...must be ducted to the outside Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options...

Page 10: ...Installation Specifications Top View 3 4 View Back View 34 3 8 40 3 8 46 3 8 3 12 28 3 8 34 3 8 40 3 8 22 1 2 5 5 8 C L 10 34 12 40 15 46 18 58 27 2 elec k o C L 10 3 8 34 12 40 15 46 18 58 27 4 3 8...

Page 11: ...120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also...

Page 12: ...cause personal injury or damage to cooking surface or counter 5 Finalize installation of electrical and duct work Seal duct work with certified aluminum duct tape Power on insert check for leaks aroun...

Page 13: ...panels by removing 2 screws from behind each panel Installation Insert Preparation 1 2 1 1 2 Locking Tabs Bottom Panel Screws 2 2 1 4 Remove bottom panel by 1 Removing 2 screws from left and right sid...

Page 14: ...on 2 Lights Dim Bright Off 1 Blower On Off Speed Selection 2 Lights Dim Bright Off Rotate dial to change speed levels 1 for low speed 2 for medium speed and 3 for high speed Rotate dial to change ligh...

Page 15: ...are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using...

Page 16: ...o prolonged use firmly attach the glass suction cup provided to the bulb or use a rubber latex glove and turn counter clockwise Directional Lighting The light bulbs can be tilted forwards and backward...

Page 17: ...15 USE ONLY TYPE MR16 GU10 35W MAX HALOGEN LIGHT BULBS AK9834AS AK9840AS AK9846AS AK9858AS VOLTS HZ MAX AMPS 120 60 Dual Motor 9 CIRCUIT DIAGRAM 2 A B 3 4 2 A B 3 4 Wiring Diagram...

Page 18: ...possibly seized 5 Change the blower The unit is vibrating 1 The blower is not secure in place 1 Tighten the blower in place 2 The hood is not secured in place 2 Check the installation of the hood 3 Da...

Page 19: ...arranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SH...

Page 20: ...our new range hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures w...

Reviews: