background image

INSTALLATION

INSTALLATION

Mounting the Range Hood

1. Determine and mark the mounting 

position of the range hood with a pencil.

2. Cut out the opening where the range 

hood will be installed.

3. Cut out wall or ceiling area for clearance 

of ductwork. Install ductwork prior to 
range hood.

4. Determine location for the power 

supply cable. After drilling access hole,
rout the cable into the electrical box 
of the range hood. Secure with a cable 
lock and connect to range hood 
electrical system.

5. Position range hood into location and 

ensure spring loaded catch has locked 
into position.

6. Fasten wood screws into wood frame 

opening

ELECTRICAL

Locking device

Screw in place

Power supply cable

Entry into range hood

Ductwork connection

All Electrical work must by performed by qualified electrician or person with similar technical
know how and background.

For personal safety, remove house fuse or open circuit breaker before beginning installation.
Do not use extension cord or adapter plug with this appliance.

Follow National electrical codes or prevailing local codes and ordinances.

Electrical Supply:

This appliance requires a 120V 60Hz electrical supply., and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer Electrical Diagram labeled on product.

Cable Lock:

A cable locking connector (not
supplied) might also required by
local codes. Check with local
requirements and codes, purchase
and install appropriate connector if
necessary.

Cable Lock

WARNING 

INSTALLATION

SPECIFICATIONS

10"

15-1/4"

16-3/16"

33-3/8"

34-3/8"

2"

2-1/4"

34-3/8"

8"

1/2"Elec. K.O. 

16-3/16"

C/L

15-3/8”

(cutout)

33-1/2"(cutout)

= cutout dimension

cut out dimension

Tornado 2 unit (AK 8200 SS)

Models: AK 8100 SS, AK 8200 SS    

Page 4

Models: AK 8100 SS, AK 8200 SS    

Page 5

Summary of Contents for AK8200

Page 1: ...WXE RU VKRZHU K 0DNH VXUH WKH SRZHU LV RII EHIRUH LQVWDOOLQJ ZLULQJ RU PDLQWHQDQFLQJ 2EAD ALL NSTRUCTIONS BEFORE NSTALLING AND OPERATING THIS APPLIANCE MPORTANT 3AFETY OTICE 5SE ARE AND NSTALLATION UI...

Page 2: ...N ON RIGHT TO COMPUTE TOTAL AVAILABLE DUCT RUN WHEN USING ELBOWS TRANSITIONS AND CAPS 7 93 WHEN POSSIBLE REDUCE THE NUMBER OR TRANSITIONS AND TURNS F LONG DUCT RUN IS REQUIRED INCREASE DUCT SIZE FROM...

Page 3: ...into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w...

Page 4: ...nical know how and background For personal safety remove house fuse or open circuit breaker before beginning installation Do not use extension cord or adapter plug with this appliance Follow National...

Page 5: ...due and grease from cooking will collect in the residue cups located inside the range hood behind the perforated diffuser panels Periodically unscrew the inlet panels and remove the residue cups for c...

Page 6: ...s The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damag...

Page 7: ...oof of purchase with date ready for warranty issues Or write to Zephyr Corporation Service and Warranty Department 395 Mendell Street San Francisco CA 94124 TO OBTAIN SERVICE UNDER WARRANTY or any Ser...

Reviews: