background image

31

Breeze I & Breeze II Use, Care, and Installation Guide

ZEPHYRONLINE.COM

Limited Warranty

Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein 
as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or 
workmanship as follows: 

Three Year Limited Warranty for Parts: 

For three years from the date of your original purchase of the Products, we will 

provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to 
manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or 
replace parts before we elect to replace the Products.

One Year Limited Warranty for Labor: 

For one year from the date of your original purchase of the Products, we will 

provide, free of charge, the labor cost associated with repairing the Products or parts to replace those that failed due to 
manufacturing defects subject to the exclusions and limitations below. After the first year from the date of your original 
purchase, you are responsible for all labor costs associated with this warranty.

Warranty Exclusions: 

This warranty covers only repair or replacement, at our option, of defective Products or parts and 

does not cover any other costs related to the Products including but not limited to: (a) normal maintenance and service 
required for the Products and consumable parts such as fluorescent, incandescent or halogen light bulbs, mesh and char-
coal filters and fuses; (b) any Products or parts which have been subject to freight damage, misuse, negligence, accident, 
faulty installation or installation contrary to recommended installation instructions, improper maintenance or repair (other 
than by us); (c) commercial or government use of the Products or use otherwise inconsistent with its intended purpose; (d) 
natural wear of the finish of the Products or wear caused by improper maintenance, use of corrosive and abrasive cleaning 
products, pads, and oven cleaner products; (e) chips, dents or cracks caused by abuse or misuse of the Products; (f) service 
trips to your home to teach you how to use the Products; (g) damage to the Products caused by accident, fire, floods, acts 
of God; or (h) Custom installations or alterations that impact serviceability of the Products. If you are outside our service 
area, additional charges may apply for shipping costs for warranty repair at our designated service locations and for the 
travel cost to have a service technician come to your home to repair, remove or reinstall the Products. After the first year 
from the date of your original purchase, you are also responsible for all labor costs associated with this warranty. All Products 
must be installed by a qualified professional installer to be eligible for warranty repairs or service.

Limitations of Warranty. OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE YOUR SOLE 
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. WE SHALL NOT BE LIABLE FOR INCIDENTAL, 
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR 
PERFORMANCE OF THE PRODUCTS. THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE 
EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. WE HEREBY DISCLAIM AND EXCLUDE ALL 
OTHER EXPRESS WARRANTIES FOR THE PRODUCTS, AND DISCLAIM AND EXCLUDE ALL WARRANTIES 
IMPLIED BY LAW, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE

.

Some states or provinces do not allow limitations on the duration of an implied warranty or the exclusion or limitation of 
incidental or consequential damages, so the above limitations or exclusions may not apply to you. To the extent that 
applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the
same three-year and one-year periods described above if permitted by applicable law. Any oral or written description of the 
Products is for the sole purpose of identifying the Products and shall not be construed as an express warranty. Prior to 
using, implementing or permitting use of the Products, you shall determine the suitability of the Products for the intended 
use, and you shall assume all risk and liability whatsoever in connection with such determination. We reserve the right to 
use functionally equivalent refurbished or reconditioned parts or Products as warranty replacements or as part of warranty 
service. This warranty is not transferable from the original purchaser and only applies to the consumer residence where the 
Product was originally installed located in the United States and Canada. This warranty is not extended to resellers. 

To Obtain Service Under Limited Warranty: 

To qualify for warranty service, you must: (a) notify us at the address or 

telephone number stated below within 60 days of the discovery of the defect; (b) give the model number and serial number; 
and (c) describe the nature of any defect in the Product or part. At the time of the request for warranty service, you must 
present evidence of your proof of purchase and proof of the original purchase date. If we determine that the warranty 
exclusions listed above apply or if you fail to provide the necessary documentation to obtain service, you will be responsible 
for all shipping, travel, labor and other costs related to the services.  This warranty is not extended or restarted upon warranty
repair or replacements.
Please check our website for any additional Product information, 

www.zephyronline.com

Zephyr, 2277 Harbor Bay Parkway, Alameda, CA 94502

 

 

TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS 

United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact

Canada Customers please call: 1-800-361-0799 or Email: [email protected]

y

Summary of Contents for AK1200CW

Page 1: ...WWW ZEPHYRONLINE COM JUL21 0301 Breeze I AK1124Bx AK1100Bx AK1136Bx EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation Breeze II AK1200Cx AK1236Cx...

Page 2: ...2 Breeze I Breeze II Use Care and Installation Guide BREEZE I BREEZE II UNDER CABINET CORE...

Page 3: ...AK11 Hood Speci cations 12 AK12 Hood Speci cations 13 Electrical Supply 14 Cable Lock 14 AK11 Installation Preparation 15 AK12 Installation Preparation 16 AK11 Ductless Recirculation Conversion 17 18...

Page 4: ...means cannot be locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result in exten...

Page 5: ...ithin walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must...

Page 6: ...ance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes p...

Page 7: ...7 round transition adapter AK12 only pre installed 1 Rectangular top transition plate AK12 only 1 Rectangular top cover plate AK12 only pre installed 1 Hardware package 6 x 1 4 6 x 1 1 2 4 6 x 2 4 M4...

Page 8: ...30 Ft x Ft Ft Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed 150 equi...

Page 9: ...learance Ducting 36 20 min 24 min 32 max NOTE The Breeze I minimum mount height for electric cook tops is 20 but is 24 for gas cook tops The Breeze II minimum mount height for both electric and gas co...

Page 10: ...hould be no less than 20 for electric cook tops and 24 for gas cook tops Maximum mount height should be no higher than 32 Breeze II Minimum mount height between range top to hood bottom should be no l...

Page 11: ...pe all joints w certi ed Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust must be ducted to th...

Page 12: ...n Instructions 35 15 16 36 29 15 16 30 23 15 16 24 33 7 8 36 27 7 8 30 22 1 16 24 33 5 8 36 27 5 8 30 21 5 8 24 2 3 4 C L 8 5 8 1 3 8 9 1 16 2 12 3 16 10 7 8 3 4 9 1 16 elec k o elec k o 5 1 2 14 3 8...

Page 13: ...ructions 27 1 2 30 33 1 2 36 8 5 8 1 1 2 2 3 4 19 11 16 4 13 16 2 1 15 16 6 15 16 2 3 4 11 1 4 5 16 3 3 4 1 13 16 14 3 8 6 3 16 2 1 2 20 5 1 2 TOP BACK SIDE 27 7 8 30 33 7 8 36 12 29 7 8 30 35 7 8 36...

Page 14: ...use extension cord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to...

Page 15: ...15 Breeze I Breeze II Use Care and Installation Guide ZEPHYRONLINE COM Installation Instructions AK11 Installation Preparation...

Page 16: ...16 Breeze I Breeze II Use Care and Installation Guide BREEZE I BREEZE II UNDER CABINET CORE Installation Instructions AK12 Installation Preparation...

Page 17: ...the safety grille body A Do this by inserting the screw through the spring and into the clip Secure each clip to the safety grille body by using a philips head screwdriver holder and place it over th...

Page 18: ...AK11 Ductless Recirculation Conversion 5 Remove each of the 5 screws holding the 2 interior recirculating panels 6 Remove 2 interior recirculating panels 7 Place louvered recirculating plate over top...

Page 19: ...e safety grille body by lifting up on spring clips and twisting The clip securely 5 Remove each screw from recirculating top plate Plate is located on top of hood towards the front NOTE Skip the recir...

Page 20: ...ange hood in the desired mounting location Measure and mark the mounting holes duct and electrical locations with a pencil 5 Drill cut out the required openings for duct and electrical access by follo...

Page 21: ...s This switch turns the blower on and off and controls the speed selection is off is low speed is medium speed and is high speed is off is dim II is bright Lights Off Dim Bright Lights Off Dim Bright...

Page 22: ...22 Breeze I Breeze II Use Care and Installation Guide BREEZE I BREEZE II UNDER CABINET CORE Features Controls 1 2 1 2 3 1 2 AK12 Electronic Touch Controls...

Page 23: ...o ber cloth and buff in the direction of the stainless steel grain Cleaning Black Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro ber cloth To remove heavier g...

Page 24: ...m Mesh Filters FIG D 1 Push in on lter handles 2 Pivot front of lter downward 3 Remove lter by pulling away from hood Replacing Aluminum Mesh Filters Hood Model Part Number Qty to Order AK1124Bx 50200...

Page 25: ...yr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED Removal FIG E 1 Remove aluminum mesh lters 2 Remove light panel by two screws 3 Di...

Page 26: ...CORE Wiring Diagram WHITE BLUE BLACK MOTOR BROWN WHITE BLACK BODY RED BLACK GREEN B W LED B W B W YELLOW WHITE WHITE GRAY AK1124Bx Wiring Diagram WHITE BLUE YELLOW WHITE WHITE BLACK MOTOR BROWN WHITE...

Page 27: ...Installation Guide ZEPHYRONLINE COM Wiring Diagram LED LED BODY GREEN WHITE BLACK WHITE BLACK BROWN BLUE WHITE BLACK BROWN BLUE MOTOR A MOTOR A MOTOR A MOTOR B YELLOW YELLOW WHITE BLACK BROWN BLUE AK1...

Page 28: ...ged blower wheel Replace the blower The hood is not secured in place Check the installation of the hood The blower is working but the lights are not The LED light connector is disconnected Connect the...

Page 29: ...rts LumiLight LED 6W AK11 Z0B0049 LumiLight LED 6W AK12 Z0B0047 Mesh Filter 24 hoods each 50200013 Mesh Filter 30 and 36 hoods each 50200012 Optional Accessories Recirculating Kit AK11 0AK11 21001 Rec...

Page 30: ...30 Breeze I Breeze II Use Care and Installation Guide BREEZE I BREEZE II UNDER CABINET CORE Notes...

Page 31: ...staller to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NO...

Page 32: ...Please take a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more...

Page 33: ...WWW ZEPHYRONLINE COM JUL21 0301 Breeze I AK1124Bx AK1100Bx AK1136Bx EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation Breeze II AK1200Cx AK1236Cx...

Page 34: ...2 Breeze I Breeze II Guide d utilisation d entretien et d installation BREEZE I BREEZE II SOUS ARMOIRE CORE...

Page 35: ...e la hotte AK11 12 Sp ci cations de la hotte AK12 13 Fourniture lectrique 14 Raccord de c ble 14 Pr paration de l installation de AK11 15 Pr paration de l installation de AK12 16 Conversion de recircu...

Page 36: ...le fabricant b Avant l entretien ou le nettoyage de l unit coupez l alimentation au panneau de service et verrouillez les moyens de d connexion de service pour viter toute mise sous tension accidente...

Page 37: ...et normes applicables y compris la construction r sistant au feu b Une quantit d air suffisante est n cessaire pour une combustion et une vacuation correctes des gaz par le conduit de fum e chemin e...

Page 38: ...n lectrique est ad quate et conforme au National Electrical Code ANSI NFPA 70 derni re dition ou aux normes CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 No 0 M91 derni re dition et tous...

Page 39: ...on rond de 7 po AK12 pre install 1 Plaque de transition sup rieure rectangulaire AK12 uniquement 1 Plaque de recouvrement sup rieure rectangulaire AK12 uniquement pre install 1 Trousse de quincailleri...

Page 40: ...ongueur x Nombre utilis rect droit circ droit rect coude 90 rect coude 45 rect coude plat 90 circ coude 90 coude 45 Sous total colonne 1 Longueur maximale du conduit d a ration Pour un mouvement d air...

Page 41: ...n 32 po max REMARQUE La hauteur minimale de montage Breeze I pour les tables de cuisson lectriques est de 20 po mais est de 24 po pour les tables de cuisson gaz La hauteur de montage minimale du Breez...

Page 42: ...de cuisson au gaz La hauteur de montage maximale ne doit pas d passer 32 pouces Breeze II La hauteur de montage minimale entre le haut de la cuisini re et le bas de la hotte ne doit pas tre inf rieure...

Page 43: ...ou du ruban adh sif Risque d incendie NE JAMAIS vacuer l air ni terminer de conduits dans des espaces entre les murs les vides sanitaires les plafonds les greniers ou les garages Tout l chappement do...

Page 44: ...15 16 36 29 15 16 30 23 15 16 24 33 7 8 36 27 7 8 30 22 1 16 24 33 5 8 36 27 5 8 30 21 5 8 24 2 3 4 C L 8 5 8 1 3 8 9 1 16 2 12 3 16 10 7 8 3 4 9 1 16 Entr e d fon able pour l lectricit 5 1 2 14 3 8...

Page 45: ...16 po 4 13 16 po 2 po 1 15 16 po 6 15 16 po 2 3 4 po 11 1 4 po 5 16 po 3 3 4 po 1 13 16 po 14 3 8 po 6 3 16 po 2 1 2 p o 20 po 5 1 2 po DESSUS ARRI RE C T 27 7 8 po 30 po 33 7 8 po 36 po 12 po 29 7 8...

Page 46: ...circuit de d rivation individuel correctement mis la terre prot g par un disjoncteur de 15 ou 20 amp res ou un fusible temporis Le c blage doit tre 2 ls avec terre Veuillez galement vous r f rer au s...

Page 47: ...es pour l lectricit sur le dessus ou l arri re de la hotte raccord de c ble Remarques Certaines normes et r glementations locales exigent l utilisation d un raccord de c ble assurez vous de respecter...

Page 48: ...circulation sans conduit ignorez les tapes 4 et 5 Si un conduit de 3 1 4 po x 10 po est souhait retirer la plaque d foncer l arri re de la hotte pour un conduit horizontal ou retirer l adaptateur de t...

Page 49: ...a grille de protection A Pour y parvenir faites passer la vis travers le solidement l attache au bo tier de la grille de protection l aide d un tournevis pointe cruciforme Phillips sur le bo tier de l...

Page 50: ...ation sans conduit AK11 5 Enlevez les cinq vis qui retiennent les deux panneaux de reprise d air int rieurs 6 Enlevez les deux panneaux de reprise d air int rieurs en place l aide des vis pr alablemen...

Page 51: ...utiliser la hotte en mode recirculation Kit de recirculation ZRC 0012 Filtre de remplacement 0AK11 20001 s curit les tournant Le clip doit couvrir la l vre du 5 Retirez chaque vis de la plaque sup rie...

Page 52: ...quez les trous de montage les conduits et les emplacements lectriques avec un crayon 5 Percez d coupez les ouvertures requises pour le conduit et l acc s lectrique en suivant les dimensions de las pag...

Page 53: ...Allumer teindre Veilleuse Ventilateur Marche Arr t Choix de Vitesse Cet interrupteur permet d allumer d teindre et de s lectionner la vitesse des ventilateurs 0 l appareil est teint I quivaut la vites...

Page 54: ...t les lumi res forte intensit Arr t retardement Lorsque la hotte est allum e appuyez sur la touche et tenez la enfonc e deux secondes Les ventilateurs passeront la vitesse 1 et la touche clignotera in...

Page 55: ...cro bres et polissez dans le sens du grain de l acier inoxydable Nettoyage de l acier inoxydable noir Nettoyez p riodiquement avec de l eau chaude savonneuse et un chiffon en coton propre ou un chiffo...

Page 56: ...r les poign es du ltre 2 Faites pivoter l avant du ltre vers le bas 3 Retirez le ltre en l loignant de la hotte Mod le de capot Num ro d article Quantit commander AK1124Bx 50200013 2 AK1100Bx AK1136Bx...

Page 57: ...rechange Voir la page de la liste des pi ces et accessoires pour les num ros de pi ces et les coordonn es Retrait de la LED LumiLight FIG E 1 Retirez les ltres mailles en aluminium 2 Retirez le panne...

Page 58: ...age BLANC BLEU JAUNE BLANC BLANC NOIR MOTOR MARRON BLANC NOIR CORPS ROUGE NOIR VERT NOIR BLANC NOIR BLANC LED NOIR BLANC GRIS Sch ma de c blage de l AK1124Bx BLANC BLEU JAUNE BLANC BLANC NOIR MOTOR MA...

Page 59: ...d entretien et d installation ZEPHYRONLINE COM Sch ma de c blage LED LED CORPS VERT BLANC NOIR BLANC NOIR MARRON BLEU BLANC NOIR MARRON BLEU MOTEUR A MOTEUR B JAUNE JAUNE BLANC NOIR MARRON BLEU Sch m...

Page 60: ...ommag e Remplacez le ventilateur Le capot n est pas x en place V ri ez l installation de la hotte Le ventilateur fonctionne mais pas les lumi res Le connecteur de la lumineuse LED est d connect Connec...

Page 61: ...Light LED 6 W AK11 Z0B0049 LumiLight LED 6W AK12 Z0B0047 Filtre maill l hottes de 24 po chacune 50200013 Filtre maill hottes de 30 po et 36 po chacune 50200012 Accessoires optionnels Kit de recirculat...

Page 62: ...30 Breeze I Breeze II Guide d utilisation d entretien et d installation BREEZE I BREEZE II SOUS ARMOIRE CORE Remarques...

Page 63: ...le de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOU...

Page 64: ...nouvelle produit au www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Cet enregistrement rapide est utile bien des gards C EST IMPORTANT Il ass...

Reviews: