3
8. Explanation of Airdolphin Operations
3
During operation, the indicator LED on the body of
the Airdolphin can be used to check the operating
status of the system.
The indicator LED can light in solid or flashing red,
green and orange (red and green).
Indicator LED
Mode
Indicator Status
Status
Cause
Operation
Power Assist
Mode
Solid Orange
Power Assist rotates
the A irdolphin at
80rpm in 10-second
every minute
No wind for 1 minute
Operating Normally
Normal Mode 1
50rpm–
1000rpm
Solid Green
Generating electricity
Wind speed - 10m/s
Rotor rotating at 50–
1000rpm
Operating Normally
Normal Mode
(1000rpm)
Flashing Green
Generating electricity
Wind speed 10 - 0m/s
Rotor rotating at 1000 rpm
Operating Normally
Normal Mode 3
(600rpm)
Solid Red
Generating electricity
Wind speed 0m/s -
a. Battery fully charged
(voltage exceeds 59.V)
b. At around 0m/s or
more of wind speed
Operating Normally
Stop Mode
Flashing Red and
Green
Rtating slowly or stop
Power assist stop
a. Over voltage (battery
voltage exceeded 7V)
b.
Generator ambient tem-
perature exceeded 90°C
a. System returns
to normal mode
if the battery volt-
age drops below
53.V.
b. System returns
to normal mode if
generator motor
ambi-ent tempera-
ture drops below
60°C
Restart
(Same as start
mode)
Solid green for 10
seconds, flashing
orange for 5 sec-
onds, solid red for
90 seconds
Power On/Off
System started
in normal mode
Operating Status List