2277 Harbor Bay Pkwy | Alameda, CA 94502 | 888.880.VENT | www.zephyronline.com

D E C 1 2 . 0101

- Vertical Duct Application
- Foam Seal for Damper Closure

A B

C

D

E

6”

7”

8”

6” 6” 2-

7/8

” 2-

7/8

” 1/4”

7” 7” 3-

1/4

” 3-

1/4

” 1/2”

8” 8” 3-

5/8

” 3-

5/8

” 3/4”

AK00029
AK00049
AK00069

M O D E L

D U C T

S I Z E

D I M E N S I O N S

BACK DRAFT  DAMPE

FEATURES

3/4 View

Side View

A

B

E

D

C

- Galvanized (G-90)
- NOT FOR USE WITH DRYER
  VENT APPLICATIONS

Side View

C

B

A

A

B

C

7x6”

8x6”

8x7”

1-

3/4

” 1-

3/4

5”

4-

3/4

4-

1/4

10x8”

5”

- Tapered for Best Air Flow
- Galvanized (G-90)

1-

3/4

” 1-

3/4

1-

3/4

” 1-

3/4

1-

3/4

” 1-

3/4

TAPERED REDUCER  

FEATURES

AK00039
AK00037
AK00035
AK00040

M O D E L

D U C T

S I Z E

D I M E N S I O N S

R

  

round damper to prevent return-air from entering kitchen

Reduces round duct size

Summary of Contents for AIN-M80ASX

Page 1: ...www zephyronline com Wave AWA M90AWX AWA M90ABX Incline AIN M80AWX AIN M80ASX RANGE HOOD Installation and use instructions ENGLISH 3 FRAN AIS 33...

Page 2: ...y Duct cover accessory sold separately Box Cover box marked 120 VAC Input Box marked 120 VAC Input Led Mesh Filter Hardware Packet Remote Blower Collar with Damper External motor Remote Blower Box Cov...

Page 3: ...Duct cover accessory sold separately Box Cover box marked 120 VAC Input Box marked 120 VAC Input Led Mesh Filter Hardware Packet Remote Blower Collar with Damper External motor Remote Blower Box Cover...

Page 4: ...8 DUCTING CALCULATION SHEET Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet...

Page 5: ...9 HOOD SPECIFICATIONS Incline...

Page 6: ...10 HOOD SPECIFICATIONS Wave...

Page 7: ...11 WIRING DIAGRAM...

Page 8: ...ible 4 Install a roof or wall cap Connect round metal ductwork to cap and work back towards hood location Use duct tape to seal the joints between ductwork sections Fig 7 FIG 7 ROOF CAP OPTIONAL DUCT...

Page 9: ...NTING SCREWS Supplied with the motor CHOOSE AIR OUTLET LOCATION The hood is supplied with upper air outlet but you can let the air out the back turning the motor plate Rotation of the motor plate 1 Re...

Page 10: ...straight short duct run using a minimum 8 round duct will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them...

Page 11: ...refer to manual included with the blower 1 Remove the knockout A Fig 14 2 Fix the wiring box marked Motor Connection with 2 3 9x6mm screws and 2 washers Fig 15 3 Install 8 round collar to top of the...

Page 12: ...he dimensions shown 2 Determine desired height over cook top and mark hood bottom line Install screws per dimensions shown in Fig 17 18 3 Hang the hood onto the screws 4 Tighten mounting screws Add ad...

Page 13: ...apacitor box screwing the 2 3 9x9 5 mm screws D 3 Remove the wiring box cover E Remove a knockout from the wiring box 4 Secure the conduit to the wiring box through a conduit connector 5 Make electric...

Page 14: ...22 FIG 20 A B C D E WIRING BOX COVER MODEL WAVE GROUND BOX MARKED 120 VAC INPUT CONNECT WHITE TO WHITE BLACK TO BLACK GREEN TO GROUND...

Page 15: ...lower box marked motor connection Connect white to white black to black blue to blue red to red green to ground Fig 21B 6 Replace the wiring box covers and screws For wiring box marked Motor Connectio...

Page 16: ...BLACK GREEN TO GROUND A BOX MARKED 120 VAC INPUT B REMOTE BLOWER HOOD WIRE HARNESS FIG 21 WHITE COMMON BLACK HIGH BLUE MED RED LOW GREEN GROUND REMOTE BLOWER BOX CONNECT WHITE TO WHITE BLACK TO BLACK...

Page 17: ...ceiling using 2 4 8 x 38mm mounting screws and drywall anchors Fig 23 Make sure the bracket is pushed into the corner tight against the wall if necessary and centered over the hood 4 Run metal ductwo...

Page 18: ...26 3 9 x 6 mm Flat Head SCREWS 7 Install upper and lower duct covers onto the range hood Fig 25 8 Secure upper duct cover to flue mounting bracket with 2 3 9 x 6 mm screws Fig 26 UPPER DUCT COVER LOW...

Page 19: ...filter and lock it with a charcoal filter holders Fig 28 Make sure the filter is securely engaged after assembly Model Wave Reassemble the metal panel with 6 M4x8mm screws See Fig 10 Install the char...

Page 20: ...from the hood Tilt the filter downward and remove Fig 32 2 To install the MESH filter align rear filter tabs with slots in the hood Pull latch tab down Push filter into place and release tab Make sur...

Page 21: ...emove the CHARCOAL filter open the upper front glass Fig 33 and remove the mesh filter Grip and push charcoal filter tab toward rear of hood Pull the filter down to disengage the rear filter tabs Fig...

Page 22: ...ONAL ACCESSORIES Recirculating Kit AIN ZRC 00IN Recirculating Kit AWA ZRC 00WA Replacement Charcoal Filters AIN Z0F 02AC Replacement Charcoal Filters AWA Z0F 01AC Duct Cover Kit AIN Z1C 00IN Duct Cove...

Page 23: ...a C r e w o L 5 2 1 0 0 3 0 5 6 1 X B A 0 9 M A W A y p o n a C r e w o L 6 2 1 0 0 3 0 5 6 2 t e n g a M y p o n a C 2 0 0 0 2 2 4 5 7 1 W 5 8 p i r t S t h g i L D E L 7 3 0 0 B 0 Z 8 1 r e t l i F...

Page 24: ...matically opens when range hood is operating Automatically closes when range hood is off 24 gauge galvanized steel construction Adjustment screw to adjust damper opening AK00030 Fresh air inlet cap wi...

Page 25: ...External Blower CBE 1000 Model number CBE 1000 Serial number U s e C a r e a n d I n s t a l l a t i o n G u i d e JUL13 0201 Zephyr Ventilation www zephyronline com Date of Purchase Sales Dealer...

Page 26: ...urner B E CARE FUL TO PREV E NT BUR NS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DE PARTMENT b NEV E R PIC K UP A FLAMING PAN You may be burned c DO NOT USE WATE R includingwe...

Page 27: ...ION ROOF MOUNT OUTSIDE WALL MOUNT Recommended for use only over conventional domestic gas and electric ranges The following instructions explain the mounting procedures for the CBE 1000 external blowe...

Page 28: ...nsition Adapter 10 to 8 Transition Adapter Remove Remove TYPICAL INSTALLATION T N U O M L L A W E D I S T U O T N U O M F O O R 3 Install blower on roof or wall with discharge screened end pointing do...

Page 29: ...1 green ground between the blower and hood Check for local code compliance for style and gauge of wires The ground wire shall have a suitable gauge according to the Electrical Code and Local Regulatio...

Page 30: ...Ventilateur Externe CBE 1000 Numero de modele CBE 1000 Numero de serie JUL13 0201 Zephyr Ventilation www zephyronline com Date d achat Detaillant Guide d utilisation d entretien et d installation...

Page 31: ...disparaissent pas VACUEZ LES LIEUX ET APPELEZ LE SERVICE D INCENDIE b NE PRENEZ JAMAIS UN PO LON EN FEU Vous pourriez vous br ler c N UTILISEZ PAS D EAU ou un linge vaisselle mouill une violente explo...

Page 32: ...ge du ventilateur externe CBE 1000 Consultez le manuel d installation de votre hotte pour obtenir des directives sur la pr paration de la hotte lors de l utilisation d un ventilateur externe Le lieu d...

Page 33: ...Enlever Fig 2 Vue en plongee Pente descendante du toit ou mur 14 18 4 1 2 7 3 4 10 1 2 1 1 2 3 Installez le ventilateur au toit ou au mur en pla ant la d charge l extr mit grillag e vers le bas confo...

Page 34: ...les cinq fils dans la conduite 1 noir 1 blanc 1 bleu 1 rouge et 1 vert de mise la terre entre le ventilateur et la hotte Assurez vous que le type et le calibre des fils respectent les codes en vigueur...

Page 35: ...Use Care and Installation Guide www zephyronline com Model number Serial Number SEP14 0201 Zephyr Ventilation LLC E12733 4 In Line Blower PBN 1000A...

Page 36: ...www zephyronline com...

Page 37: ...1 SAFETY NOTICE 2 LIST OF MATERIALS 3 INSTALLATION Ductwork Calculation Sheet 4 Blower Positions 5 Specifications 6 Mounting the Blower 7 Table of Contents...

Page 38: ...10 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat...

Page 39: ...sans surveillance lors de son utilisation haute temp rature Les d bordements par bouillonnement causent de la fum e et des d versements de graisse qui peuvent prendre feu Faites chauffer l huile des t...

Page 40: ...8 PARTS NOT SUPPLIED Ducting conduit wiring and all installation tools Cable connector if required by local codes Range hood HARDWARE PACKAGE CONTENTS MODEL 2 Mounting brackets 1 In Line blower 1 10...

Page 41: ...column 1 Duct pieces T otal Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 10 Round 900 elbow 15 Ft x Ft 7 10 7 10 Round 450 elbow 9 Ft...

Page 42: ...embers tied to trusses 3 Horizontal mount to cross members tied to trusses 4 Mount on underside of rafters with wood blocking 5 Mount to cross members tied to trusses with 90 degree elbow Note1 When a...

Page 43: ...ations 15 7 8 8 5 8 11 13 16 1 9 16 1 11 16 20 15 16 20 3 8 23 7 16 21 7 8 5 1 2 14 3 16 10 3 8 14 5 8 9 15 16 10 1 16 7 5 16 6 13 16 7 5 16 1 2 3 4 front side bracket positions top outlet bottom inle...

Page 44: ...code compliance for style and gauge of wires The ground wire shall have a suitable gauge according to the Electrical Code and Regulations Connect wires to in line blower and blower wiring harness on...

Page 45: ...ternal Single Internal Single Internal Single Internal Dual Internal Dual Internal External In line MAX WATTS 77 77 320 320 450 640 660 700 640 MAX AMPS 0 75 0 75 2 75 2 75 3 75 5 45 5 8 6 25 5 45 CFM...

Page 46: ...E D I M E N S I O N S BACK DRAFT DAMPE FEATURES 3 4 View Side View A B E D C Galvanized G 90 NOT FOR USE WITH DRYER VENT APPLICATIONS Side View C B A A B C 7x6 8x6 8x7 1 3 4 1 3 4 5 4 3 4 4 1 4 10x8 5...

Page 47: ...tch A B C D E 6 7 8 12 6 3 15 10 12 7 2 1 2 15 11 15 8 3 1 2 15 12 10 F G H I 15 10 2 1 2 20 16 3 1 4 5 1 8 5 1 8 5 1 2 6 1 2 3 1 4 3 1 2 4 1 4 1 7 8 1 7 8 2 2 1 4 3 1 4 3 1 4 3 1 4 3 1 2 AK00046 AK00...

Page 48: ...y used with make up air kits M O D E L D U C T S I Z E D I M E N S I O N S FEATURES A B C D E 6 7 6 7 5 8 8 1 8 1 2 7 8 5 8 9 5 8 1 8 1 2 8 10 11 5 8 1 3 4 8 1 2 10 F G 8 H 10 12 13 1 3 4 8 1 2 8 5 8...

Page 49: ...Use Care and Installation Guide www zephyronline com OCT13 0201 Zephyr Corporation Universal Make Up Air Damper MUA006A MUA008A MUA010A...

Page 50: ...the outside air duct directly above or closer than 2 ft to any furnace or its supply plenum boiler or other heat producing appliance 4 Any ductwork used in conjunction with the Damper must be installe...

Page 51: ...ings in exterior walls including steps to prevent moisture intrusion around the opening Note that the screen over the outside air opening is not a filter It is intended to prevent the intake of leaves...

Page 52: ...d notes as guidance for your own installation Always comply with local code requirements and in any instance where a detail shown below conflicts with local code the local code provision shall apply D...

Page 53: ...ure when the range hood exhausts at high speed PRESSURE SWITCH OPERATION The pressure switch is designed to operate when the static pressure increases to 0 05 Ps or more It may not operate at low spee...

Page 54: ...LINE BLOWER RANGE HOOD PROBE EXHAUST DUCT PRESSURE SWITCH HOOD FLUE ROOF CAP w DAMPER INLINE BLOWER TYPICAL INSTALLATION WITH EXTERIOR BLOWER RANGE HOOD PROBE EXHAUST DUCT PRESSURE SWITCH HOOD FLUE EX...

Page 55: ...PROBE PRESSURE SWITCH PRESSURE SWITCH TUBING PROBE air flow arrow pointing in direction of air flow AIR FLOW DUCTWORK GASKET SHEET METAL SCREWS Connect tubing onto outside of black fitting Drill 3 8...

Page 56: ...ood and check to see if the damper closes A qualified HVAC contractor should also ensure the proper operation and venting of all combustion equipment in the home Wire the system as shown FALSE TRIPPIN...

Page 57: ...dvised And in homes with more than one of these conditions make up air for the range hood is strongly advised 5 What are the benefits of providing make up air to replace air which is exhausted out of...

Page 58: ...NOTES 99044999B...

Page 59: ...Guide d utilisation d entretien et d installation www zephyronline com OCT13 0201 Zephyr Corporation CLAPET UNIVERSEL D AIR DE COMPENSATION MUA006A MUA008A MUA010A...

Page 60: ...ext rieur 3 Ne placez pas le conduit d arriv e d air ext rieur directement au dessus d un appareil de chauffage d un caisson de distribution ou d une chaudi re ni moins de 60 cm 2 pi 4 Installez tout...

Page 61: ...les murs ext rieurs dont les mesures prendre pour emp cher l entr e d humidit autour de l ouverture Veuillez noter que le grillage de la prise d air ne constitue pas un filtre Il ne vise qu emp cher l...

Page 62: ...l installation Respectez toujours les exigences des codes dans toute situation o un d tail indiqu ci dessous contredirait les codes locaux Ceux ci ont pr s ance Clapet raccord la section de retour d...

Page 63: ...ue la hotte de cuisine expulse l air haute vitesse FONCTIONNEMENT DU MANOCONTACTEUR Le manocontacteur est con u pour fonctionner une augmentation de la pression statique Ps de 0 05 po et plus Il peut...

Page 64: ...s d installation HOTTE DE CUISINI RE SONDE CONDUIT D VACUATION CAPUCHON DE TOIT ET CLAPET MANOCONTACTEUR CONDUIT DE LA HOTTE INSTALLATION TYPE AVEC VENTILATEUR INTERNE ET VENT DE TOIT CLAPET SUR COND...

Page 65: ...s D BIT D AIR FILS DE BASSE TENSION Ouverture de la sonde tourn e vers le bas COSSES OUVERTES DE 1 4 PO FILS DE BASSE TENSION TUBE CONNECT L ENTR E GRIS CONDUIT HORIZONTAL MANOCONTACTEUR TUBE SONDE la...

Page 66: ...ffage et de climatisation doit galement s assurer du bon fonctionnement de tout appareil de combustion notamment l vacuation des gaz de combustion Effectuez le c blage tel qu illustr 24V 20V BORNES 24...

Page 67: ...e est fortement conseill 5 Quels avantages y a t il fournir de l air de compensation pour remplacer l air vacu l ext rieur par une hotte de cuisine Les hottes de cuisine sont con ues pour aspirer les...

Page 68: ...REMARQUES 99044999B...

Reviews: