- 21 -
FIG.19
INTERNAL BLOWER WIRING
Note: This range hood must be properly grounded. The unit should be installed by a
qualified electrician in accordance with all applicable national and local electrical codes.
See Fig.19 for Incline Model, see Fig.20 for Wave Model.
1. Make connections (A, B, C).
2. Secure capacitor box screwing the (2) 3.9x9.5 mm screws (D).
3. Remove the wiring box cover (E). Remove a knockout from the wiring box.
4. Secure the conduit to the wiring box through a conduit connector.
5. Make electrical connections. Connect white to white, black to black and green to ground.
6. Replace wiring box cover and screws. Make sure that wires are not pinched between cover
and box.
A
B
D
E
WIRING BOX
COVER
MODEL INCLINE
GROUND
C
BOX MARKED
“120 VAC INPUT”
CONNECT:
WHITE-TO-WHITE,
BLACK,-TO-BLACK,
GREEN-TO-GROUND.