- 23 -

FIG.21

MOUNTING
SCREWS
3,9x6 mm

INSTALL THE HOOD

Insert 8 screws (3.9x6mm),  located in the
Hardware Package (Fig. 21).

DUCTED INSTALLATION ONLY

Note: Rooms with 10 to 12 foot ceiling
require duct cover extension/support
frame model Z1C-02LL, available from
your local dealer.
Discard the duct covere extension/
support frame supplied with the range
hood and replace it with the longer duct
cover extension.

1. Run 6-inch diameter metal ductwork to

the outside location (Fig.22).

2. Install an appropriate wall or roof cap

with damper to exhaust the air to the
outside.

3. Tape all duct joints with aluminum duct

tape.

NON-DUCTED INSTALLATION ONLY

Note:
a. Purchase Model ZRC-01LL Non-

ducted Recirculating Kit from your
local dealer.

b. Rooms with 10 to 12 foot ceiling

require duct cover extension/support
frame model Z1C-02LL, available
from your local dealer.
Discard the duct cover extension/
support frame supplied with the
range hood and replace it with the
longer  duct cover extension.

1. Install the plenum to the frame using

(4) 3.9 x 6 mm screws provided as
shown (Fig.23).

2. Install the 6” duct connector.
3. Attach 6-inch expandable ducting to the

plenum and tape joint with aluminum
duct tape.

FIG.22

6-INCH DIA.
METAL DUCT

FIG.23

PLENUM

MOUNTING SCREWS
(3.9 x 6mm Flat Head)

6” DUCT

CONNECTOR

Summary of Contents for ADL-E42BSX

Page 1: ...www zephyronline com RANGE HOOD Installation and use instructions ENGLISH 3 FRAN AIS 29 Layers Island ALL M90BBX ALL M90BWX ALL E42BBX ALL E42BWX Duo Island ADL M90BSX ADL E42BSX...

Page 2: ...mum 6 round duct will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof cap Con...

Page 3: ...the flange may already be pre installed Fig 8 2 Remove the blower plate unscrewing the 4 3 9x9 5 mm screws Fig 9 3 Install internal blower into blower plate and secure using 4 screws Fig 10 4 Install...

Page 4: ...x9 5 mm screws Fig 13A 2 Make connections B C D Fig 13 3 Remove the wiring box cover Remove a knockout from the wiring box Fig 14E 4 Secure the conduit to the wiring box through a conduit connector 5...

Page 5: ...or mounting location suggestions and restrictions 2 A straight short duct run using a minimum 8 round duct will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will...

Page 6: ...etails refer to manual included with the blower 1 Remove the blower plate unscrewing the 4 3 9x9 5 mm screws Fig 15 2 Install the external blower plate and secure using 4 3 9x6 mm screws Fig 16 3 Inst...

Page 7: ...electrical connections remote blower box marked motor connection Connect white to white black to black blue to blue red to red green to ground Fig 18B 6 Replace the wiring box covers and screws Make s...

Page 8: ...n the 8 screws in the height adjustment holes as necessary Insert 8 screws 3 9x6 mm located in the Hardware Package Fig 19 4 Secure the support frame to joists and cross framing with four 4 screws pro...

Page 9: ...e air to the outside 3 Tape all duct joints with aluminum duct tape NON DUCTED INSTALLATION ONLY Note a Purchase Model ZRC 01LL Non ducted Recirculating Kit from your local dealer b Rooms with 10 to 1...

Page 10: ...th 4 3 9 x 9 5 mm screws Fig 24 Vents may be exposed on 10 to 12 foot ceilings 2 Secure the two lower duct covers parts to the support frame by overlapping the lateral magnets Fig 25 FIG 24 FIG 25 UPP...

Page 11: ...filter into place and release tab Make sure the filter is securely engaged after installation NON DUCTED HOODS ONLY 1 To remove the CHARCOAL filter grip and push filter tab toward rear of hood Pull th...

Page 12: ...0031 Metal Mesh Filter ALL 50200033 OPTIONAL ACCESSORIES Recirculating Kit ADL ALL ZRC 01LL Replacement Charcoal Filters ADL ALL Z0F 01AC Extension Flue up to 12 ADL ALL Z1C 02LL To order parts visit...

Reviews: