Connection
of
wires
1. Indoor unit
Open upward the inlet grid to the greatest extends.
Remove the electric cover from the unit.
Loose the screw at connection lid. (Fig.12)
Dismantle the wire pressure plate.
Connect the power connecting wires and signal control wire separately
to the corresponding terminals. (In Fig.14, please choose the same
wiring diagram just with the wiring diagram of unit)
Loose off the screw on the earth plate; press earth wire tightly.
Press tightly the connecting wires of the unit with lead wire pressure
plate.
Close the connection lid screw it tightly and close the inlet grid.
2. Outdoor unit
Unscrew and dismantle the electronic device lid (Fig.13).
Dismantle the pressure plate of wire fastener.
Connect the connecting wires of the unit separately to the corresponding terminals.
(Fig.14)
Press tightly the connecting wires of the unit with top pressure plate.
Remount the electronic device lid to the original position.
If user wants to prolong or replace the power wire, please do it according to the table n°3.
ф
6 (1/4'')
15~20
ф
9.52(3/8'')
35~40
ф
12(1/2'')
50~55
ф
15.88(5/8'')
60~75
ф
19.05(3/4'')
80~95