Tool Calibration
If a repair replacement motor or drive plate is required, the pruners need to be recalibrated.
Calibration Steps
1) Remove the upper and lower blades.
2) Insert the battery.
3) Hold down the trigger and remain motionless. Press the POWER switch again.
4) The trigger remains motionless for more than 20 seconds.
5) Release the trigger when you hear the motor turning.
6) The electric motor rotates during calibration. When the motor stops turning the
calibration is complete.
11. Screw the M5
hexagon socket
countersunk head
counterclockwise
as shown.
12. Lubricate properly to
reduce the friction
between the two blade
from the hole in the
plastic cap as shown in
the figure before work.