20
4.3.6 Skip AUTO.BAS
TSPL
-
EZD programming language allows user to download an auto execution file to flash
memory. Printer will run the AUTO.BAS program immediately when turning on printer power.
The AUTO.BAS program can be interrupted without running the program by the power-on utility.
Please follow the procedures below to skip an AUTO.BAS program.
1. Turn off printer power.
2. Press FEED/ PAUSE button and then turn on power.
3. Release the button when LED becomes
solid green
.
The LED color will be changed as following:
Amber
red (5 blinks)
amber (5 blinks)
green (5 blinks)
green/amber (5 blinks)
red/amber (5 blinks)
solid green
4. Printer will be interrupted to run the AUTO.BAS program.