Zennio ZRX-KCI4SO Quick Start Manual Download Page 1

© Zennio Avance y Tecnología S.L. 

Edition 5 

Futher information 

www.zennio.com

 

Page 1/2 

 

KCI 

KNX Consumption Interface 

ZRX-KCI4SO 

TECHNICAL DOCUMENTATION 

 

FEATURES 

 

4  channels  for  consumption  counters  (meters)  with  S0-pulse  outputs 
(UNE-EN 62053-31) *. 

 

Registration of consumed electric power, cost and CO2 emissions that 
can be split in up to 4 time intervals. 

 

Compliant with UNE-EN 62053-31 Class B. 

 

Total data saving on KNX bus power failure. 

 

KNX BCU integrated. 

 

Size 90 x 60 x 35 mm (2 DIN units). 

 

DIN rail unit assembly (EN 50022), with snap fit clamp. 

 

CE directives compliant (CE mark on the front side). 

 
*Other counters (meters) with  dry-voltage output or not complying S0 standard 
may also work (previous test is recommended) 
 
 

 

 

1. Battery holder 

2. EMPTY batt. LED indicator 

3. LOW batt. LED indicator 

4. Programming button 

5. Programming LED 

6. Input Indicator LED 

7. Input connectors 

8. KNX connector 

Figure 1: KCI 

Programming button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe mode. 
Programming LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red)  every half second. During the start-up 
(reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash. 
LOW batt. LED: if this LED is blinking in red, replace the batteries as soon as possible. 
EMPTY batt. LED: if this LED is blinking in red, the batteries are empty. 

GENERAL SPECIFICATIONS 

CONCEPT 

DESCRIPTION 

Type of device 

Electric operation control device 

KNX supply 

Voltage (typical) 

29VDC SELV 

Voltage range 

21..31VDC 

Maximum 
consumption 

Voltage 

mA 

mW 

29VDC (typical) 

12.5 

363 

24VDC¹ 

15 

360 

Connection type 

Typical TP1 bus connector  for 0.80mm Ø rigid cable 

External power supply 

2  CR2032  battery  (2  x  3V).  It  allows  to  keep  counting pulses without  the 
KNX bus power supply 

Operation temperature 

0°C .. +55°C 

Storage temperature 

-20°C .. +55°C 

Operation humidity 

5 .. 95% (No condens.) 

Storage humidity 

5 .. 95% (No condens.) 

Complementary characteristics 

Class B 

Protection class 

III 

Operation type 

Continuous operation 

Device action type 

Type 1 

Electrical stress period 

Long 

Degree of protection 

IP20, clean environment 

Installation 

Independent device to be mounted inside electrical panels with DIN rail (EN 
50022) 

Minimum clearances 

Not required 

Response on KNX bus failure 

Data saving according to parameterization 

Response on KNX bus restart 

Data recovery according to parameterization 

Operation indicator 

Programming  LED  indicates  programming  mode  (red)  or  safe  mode 
(blinking red). LOW and EMPTY  batt. LED indicate the battery level when 
blinking in red (KNX supply necessary). LED input indicator blinks when a 
pulse is received 

Weight 

89g (+ 6g bat.) 

PCB CTI index 

175V 

Housing material 

PC FR V0 halogen free 

¹ Maximum consumption in the worst case scenario (KNX Fan-In model) 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 