Zennio WinDoor RF Quick Start Manual Download Page 6

 

 

 

WinDoor RF / WinDoor RF 915

 

https://www.zennio.com

 

                

Technical Support:

 

https://support.zennio.com

 

 

1.3

 

DEVICE PROGRAMMING 

Once  the  battery  is  connected,  downloading  both  the  physical  address  and  the 

application program will be possible. To do this WinDoor RF must be in 

“active

 

state. 

As  long  as  there  are  no  open/close  events,  the  WinDoor  RF  remains  in  a  low 

consumption  idle  state  in  which  it  does  not  respond  to  orders  or  reading  requests, 

therefore,  it  is  necessary  to  force  it  out  of  this  idle  state  in  order  to  perform  the 

downloading.  

WinDoor RF enters the active state for 1 minute in the following cases: 

  When pressing the programming button.  

  After power failure. Resetting the device will also cause the programming led 

to blink. After this flashing WinDoor RF enters in active state. 

Note

If the programming LED does not light up when connecting the battery, 

perform a longer power failure (at least 30 seconds)

  After  the  first  window/door  closing.  The  first  time  the  closed  window/door 

contact  is  detected  since  the  last  reset,  there  will  be  several  flashes  of  the 

programming LED. After this blinking, WinDoor RF enters in active state. 

1.4

 

START-UP AND POWER LOSS 

During the start-up of the device, the programming LED will blink. 

After each restart, the status of the 

window/door

 will be sent. In addition, if the 

tamper

 

and 

battery

 

alarms

 are enabled, the status of the 2 alarms  will also be sent after the 

restart. 

 

Summary of Contents for WinDoor RF

Page 1: ...WinDoor RF WinDoor RF 915 KNX RF magnetic contact for door or window ZRFWD ZRFWD915 USER MANUAL Application program version 1 1 User manual edition 1 1 _a www zennio com...

Page 2: ...pport https support zennio com 2 CONTENTS Contents 2 Document updates 3 1 Introduction 4 1 1 WinDoor RF WinDoor RF 915 4 1 2 Installation 5 1 3 Device programming 6 1 4 Start up and power loss 6 2 Con...

Page 3: ...WinDoor RF WinDoor RF 915 https www zennio com Technical Support https support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 1 _a Internal optimisation...

Page 4: ...sily There are two different products for two different frequencies WinDoor RF ref ZRFWD for 868 MHz WinDoor RF 915 ref ZRFWD915 for 915 MHz Hereafter this document will refer to WinDoor RF genericall...

Page 5: ...next Programming button 3 a short press on this button sets the device into the programming mode making the associated LED 2 light in red Note if this button is held while plugging the battery the de...

Page 6: ...When pressing the programming button After power failure Resetting the device will also cause the programming led to blink After this flashing WinDoor RF enters in active state Note If the programming...

Page 7: ...by entering the parameters window of the device 2 1 GENERAL In General tab all the functionality of the device will be configured being its main function the sending of window door state after each o...

Page 8: ...r bus failure takes place with a delay of up to 255 seconds to prevent bus overload The following sendings match the period set Window Door Status Object enabled enables the object Window Door Status...

Page 9: ...nabled disabled enables the object Alarm Battery Status through which a 1 is sent when the battery level is about to run out Whenever this parameter is enabled Heartbeat will necessarily be enabled Im...

Page 10: ...the specifications or restrictions from both the KNX standard or the application program itself Number Size I O Flags Data type DPT Functional Range Name Function 1 1 Bit C T DPT_Trigger 0 1 Heartbea...

Page 11: ...n and send us your inquiries about Zennio devices https support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio...

Reviews: