background image

© Zennio Avance y Tecnología S.L. 

Edition 5 

Further information 

www.zennio.com

 

Page 2/2 

 

 

SAFETY INSTRUCTIONS AND ADDITIONAL NOTES 

 Installation should only be performed by qualified professionals according to the laws and regulations applicable in each  country. 

 Do not connect the mains voltage nor any other external voltage to any point of the KNX bus; it would represent a risk for th e entire 

KNX system. The facility must have enough insulation between the mains (or auxiliary) voltage and the KNX bus or the wires of other 
accessories, in case of being installed. 

 Once the device is installed (in the panel or box), it must not be accessible from outside. 

 Keep the device away from water (condensation over the device included) and do not cover it with clothes, paper or any other material 

while in use. 

 The WEEE logo means that this device contains electronic parts and it must be properly disposed of by following the instructi ons at 

https://www.zennio.com/en/legal/weee-regulation. 

OUTPUTS SPECIFICATIONS AND CONNECTIONS 

CONCEPT 

DESCRIPTION 

Number of outputs 

16 

Output type / Disconnection type 

Potential-free  outputs  through  bistable  relays  with  tungsten  pre-contact  / 
Micro-disconnection 

Rated current per output 

AC 16(6) A @ 250 VAC (4000 VA) 
DC 7 A @ 30 VDC (210 W) 

Maximum load per output 

Resistive 

4000 W 

Inductive 

1500 VA 

Maximum inrush current 

800 A/200 

μs 

165 A/20 ms 

Connections in adjacent outputs  

Possibility of connecting different phases. It is not allowed to connect power 
supplies of different order, SELV with NO SELV, in the same block  

Maximum current per block 

40 A 

Short-circuit protection 

NO 

Overload protection 

NO 

Connection method 

Screw terminal block (0.5 Nm max.) 

Cable cross-section 

1.5-4 mm² (IEC) / 26-10 AWG (UL) 

Outputs per common 

Maximum response time 

10 ms 

Mechanical lifetime (min. cycles) 

3 000 000 

Electrical lifetime (min. cycles)

100000 @ 8 A / 25000 @ 16 A (VAC) 

¹ Lifetime values could change depending on the load type. 

 In order to ensure the expected status 

of  the  relays,  please  check  that  the 
device  is  connected  to  the  KNX  bus 
before energizing the power circuit. 
 

WIRING DIAGRAMS 

Figure 2: Wiring example (from left to right): 2 loads, 2 loads 

connected to different phases, shutter and fan coil 

A1

A2

M

N

L

B1

B2

A1

A2

M

N

L

M

M

B1

B2

B1

B2

A1

A2

N

L

B1

B2

B1

A1

B2

A2

A1

A2

N

L

B1

B2

B1

B2

B1

B2

A1

A2

N

L

B1

B2

L1

L2

L1

L2

L1

L2

L3

L4

A1

A2

B1

B2

C1

C2

D1

D2

E1

E2

F1

F2

G1

G2

H1

H2

L1

L2

L3

L1

F1

F2

F3

V1

Figure 3: Mounting MAXinBOX 16 Plus on DIN rail 

Removing MAXinBOX 16 Plus from DIN rail:

 

Attaching MAXinBOX 16 Plus to DIN rail: 

 

Reviews: