1

 

INTRODUCTION 

1.1

 

KIPI SC 

KIPI SC is the solution from Zennio with 

KNX Secure 

for the 

interconnection

 of 

KNX 

twisted-pair lines 

and

 Ethernet

.

 

It also provides a 

connection point

 for ETS to enable 

programming (up to five parallel connections) and monitoring the KNX line via IP.  

KIPI SC can 

synchronize the date and time with an NTP server

 in order to send this 

information to the KNX bus and serve as the 

clock master

 of the installation. 

To ensure the exchange of KNX data in both IP and TP medium, the KIPI SC has been 

provided  with 

KNX  Secure

.  For  detailed  information  about  the  functionality  and 

configuration  of  the  KNX  security,  please  refer  to  the  specific  user  manual  "

KNX 

Secure

",  available  in  the  KIPI  SC  product  section  of  the  Zennio  web  portal 

(

www.zennio.com

). 

These are the most outstanding features of this device: 

  Maximum APDU length of 254 bytes. 

  Up to 

5 parallel connections from ETS

 for programming and monitoring (via 

group monitor). 

  No external power required. 

 

High capacity buffer

 for the reception of telegrams from the Ethernet network. 

 

4  lighting  indicators  (LEDs)

:

 

two  state  indicators

 

for  the  lines  (bus  and 

Ethernet), one more IP factory reset indicator, and one additional indicator for 

the programming mode. 

  Installation 

Clock master 

functionality, synchronized with 

NTP servers

.  

 

Heartbeat 

or periodical “still

-

alive” notification.

 

 

 

 

Summary of Contents for KIPI SC

Page 1: ...KIPI SC Secure KNX IP Interface ZSYKIPISC USER MANUAL Application Program version 1 1 User Manual version 1 1 _a www zennio com...

Page 2: ...Updates 3 1 Introduction 4 1 1 KIPI SC 4 1 2 Installation 5 1 3 LED Indicators 6 1 4 Hard Reset to Factory Defaults 7 2 Configuration 8 2 1 KNX to IP Interface 8 2 1 1 Programmer 8 2 1 2 Addicional I...

Page 3: ...KIPI SC v1 1 https www zennio com Technical Support https support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 1 _a Changes in the application program Date time synchronisation via NTP 14...

Page 4: ...with KNX Secure For detailed information about the functionality and configuration of the KNX security please refer to the specific user manual KNX Secure available in the KIPI SC product section of t...

Page 5: ...ming mode After a short press the programming LED 7 will light in red Note if the programming button is held while plugging the device into the KNX bus the device will enter into safe mode In such cas...

Page 6: ...status of the primary bus OFF error or KNX line not connected or not powered ON green TP connection OK Note the update of the LED status can be delayed a few seconds after the trigger event e g after...

Page 7: ...es its default parameters obtain an IP address via DHCP server Thus if a device becomes inaccessible on the local network due to the loss of its IP configuration the device can be located again The de...

Page 8: ...g to be used as interface because there is no need to modify the default configuration see previous section However when requiring to modify any property of KIPI SC an individual address should be ass...

Page 9: ...nt If the KIPI SC is selected as the programming interface to program itself it is recommended to first perform individual address download and then application download rather than complete download...

Page 10: ...ss 0 0 0 0 255 255 255 255 Subnet Mask 0 0 0 0 255 255 255 255 Default Gateway 0 0 0 0 255 255 255 255 Note If a static IP is configured it is important to make sure that no other device on the networ...

Page 11: ...nloads within the same project This option is only available for connections via a KNX IP router or a KNX IP interface Certain conditions must be met Each download must be performed on a different lin...

Page 12: ...al addresses must be configured Although by default the physical address of KIPI SC is 15 15 255 and tunneling addresses are 15 15 250 15 15 251 15 15 252 15 15 253 and 15 15 254 all of them can be co...

Page 13: ...the device is still working still alive Figure 9 Heartbeat Note the first sending after download or bus failure takes place with a delay of up to 255 seconds to prevent bus overload The following sen...

Page 14: ...ormation will not be synchronized 2 3 NTP CLOCK KIPI SC can be configured as the installation master clock it will send the date and time information to the rest of the devices of the installation Thi...

Page 15: ...ons from both the KNX standard or the application programme itself Number Size I O Flags Data type DPT Functional Range Name Function 1 1 Bit C T DPT_Trigger 0 1 Heartbeat Object to Send 1 Sending of...

Page 16: ...n and send us your inquiries about Zennio devices https support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio...