background image

 

 

 

IDAC

 

https://www.zennio.com/

 

            

Technical Support:

 

https://support.zennio.com/

 

 

11

 

2.2.2

 

BACKLIGHT 

The  Indoor  Module  allows  the  brightness  of  its  LED  to  be  managed  according  to  two 

operating modes: normal and night mode. 

Please refer to the specific manual “

Brightness

” (available in the IDAC product section 

at the Zennio website, 

www.zennio.com

) for detailed information about the functionality 

and the configuration of the related parameters. 

2.2.3

 

ROOM STATE BUTTONS 

The buttons of the Indoor Module are intended to control the state of the room (

normal, 

do not disturb 

and 

make-up request

).  

Two types of control are available: 

 

Do  Not  Disturb: 

a  single  button  that  switches  between 

Normal

  and 

Do  Not 

Disturb

  If  the  current  state  of  the  room  is 

Normal

  or 

Make-Up  Request

  and  the 

button is pressed, it is activated 

Do Not Disturb.

 

  If the current state of the room is 

Do Not Disturb

 and the button is pressed, 

it is activated 

Normal.

 

 

Double: 

two buttons of which the right switches between 

Do Not Disturb 

and 

Normal

 and the left between 

Make-Up Request

 and 

Normal.

 

Note

Please,  note  that the  type  of  control  must be  selected  according to the  product 

design. 

ETS PARAMETERIZATION 

When  the  function 

Room  State  Buttons 

in  “Configuration”  tab,  in  Indoor  Module,  a 

new tab will be available in the left tree. In addition, three objects will appear  and will 

allow to monitor and control the state of the room: 

“[Access] Room State Indicator” 

and 

“[Access] Room State”, “[Access] Room State: Make Up Room (Status)” 

and 

“[Access] Room State: Do Not Disturb (Status)”. 

Please refer to the 

“Access Control” 

user manual, available under the IDAC product 

section at 

www.zennio.com

, for detailed information. 

Summary of Contents for IDAC

Page 1: ...IDAC Access Controller for Installation in Door ZVIIDAC USER MANUAL ds kmfroi Application Program Version 2 0 User manual edition 2 0 _a www zennio com...

Page 2: ...Configuration 7 2 1 General 7 2 2 Indoor Module 9 2 2 1 Configuration 9 2 2 2 Backlight 11 2 2 3 Room State Buttons 11 2 2 4 Touch Locking 12 2 2 5 Sounds 13 2 2 6 Ambient Luminosity Sensor 15 2 3 Out...

Page 3: ...er the correct reading of a NFC card or BLE key data Access Locale o New binary object to inform if accesses granted during a KNX bus failure Access Offline access o Possibility to choose the action w...

Page 4: ...us Battery charging system and power supply to KNX bus by means of retractable metal contacts Outdoor module with rooms access control functionality using Cards with NFC Near Field Communication techn...

Page 5: ...mode In such case the programming LED will blink in red colour For detailed information about the technical features of the device and about the installation process please refer to the corresponding...

Page 6: ...it has power supply through a rechargeable battery although of course there will be no communication with the KNX bus Nevertheless note that to reduce the battery consumption All LED are turn off aft...

Page 7: ...sabled enabled 1 incorporates a one bit object to the project Heartbeat Object to Send 1 that will be sent periodically with a value of 1 to notify that the device is still working still alive Note Th...

Page 8: ...ion to the objects of the access control module the following General Scene Receive and General Scene Send objects for respectively receiving and sending scene values from to the KNX bus whenever it i...

Page 9: ...1 CONFIGURATION In the Configuration tab of the Indoor Module the general configurable parameters of the module are displayed Most of them are checkboxes to activate other functionalities ETS PARAMET...

Page 10: ...tarted in activity state after a download Time to Consider Inactivity 1 65535 s min h time that must elapse since the last press and or proximity detection to consider inactivity state and to set the...

Page 11: ...room is Normal or Make Up Request and the button is pressed it is activated Do Not Disturb If the current state of the room is Do Not Disturb and the button is pressed it is activated Normal Double t...

Page 12: ...1 ds during this time no press will be considered LED Color color of the LED associated to the button when the corresponding state is selected 2 2 4 TOUCH LOCKING Buttons can optionally be locked or u...

Page 13: ...locking and unlocking when receiving the configured scene value through the object General Scene receive Lock Scene Number 0 Disabled 0 1 64 scene number that locks the buttons Unlock Scene Number 0 D...

Page 14: ...TERIZATION After enabling the Customize Sounds in Configuration screen in Indoor Module see section 2 2 1 a new tab will be incorporated into the tree on the left Figure 6 Indoor Module Sounds Disable...

Page 15: ...ject for Alarm disabled enabled enables or disables the alarm function If enabled a specific object In Sounds Alarm will be included into the project topology Value 0 No Alarm 1 Alarm 0 Alarm 1 No Ala...

Page 16: ...f the indoor module it is equipped with a proximity sensor and an ambient luminosity sensor that will allow to adjust the backlight according to to different situations of presence or illumination Thi...

Page 17: ...ough the proximity sensor Please refer to the user manual Proximity and Luminosity Sensor available in the IDAC product section at the Zennio homepage www zennio com for detailed information about the...

Page 18: ...ut the functionality and configuration of the related parameters 2 3 3 BACKLIGHT The outdoor module has three LEDs each of which has a specific functionality Figure 8 Outdoor Module Backlight Access L...

Page 19: ...access LEDs will be on when trying to access the room States Configuration For each state of the room which will depend on the value of the objects Access Room State Status and Access Presence Occupan...

Page 20: ...Up Make Up Not Occupied Normal Normal Not Occupied Do Not Disturb Access Granted Do Not Disturb Access Granted Access Denied Occupied Make Up Make Up Occupied Normal Make Up Not Occupied Table 1 Stat...

Page 21: ...e has single button with doorbell functionality This button type can be configured as Switch Control whenever the user touches the button a binary value will be sent to the KNX bus This value is confi...

Page 22: ...ee section 2 3 3 If On is selected the LED Color parameter will be enabled allowing you to choose the desired color 2 3 5 TOUCH LOCKING Functionality analogous to that described for the Outdoor Module...

Page 23: ...al Module Sounds Disable Button Sounds disabled enabled enables or disables acoustic signals of actions derived from button presses and access attempts Enable Disable Button Sound Through a 1 bit Obje...

Page 24: ...IDAC https www zennio com Technical Support https support zennio com 24 2 3 7 AMBIENT LUMINOSITY SENSOR Functionality analogous to that described for the Outdoor Module see section 2 2 6...

Page 25: ...Do Not Disturb 9 1 Byte O C R T 1 xxx 0 1 Access Room State 0 Normal 1 Make Up Room 2 Do Not Disturb 10 1 Bit O C R T DPT_Bool 0 1 Access Room State Make Up Room Status 0 No Active 1 Active 11 1 Bit O...

Page 26: ...T_Switch 0 1 In Btnx Two Objects Short Press 0 1 1 Bit Generic Control 1 Byte I C W T DPT_Value_1_Ucount 0 255 In Btnx Two Objects Short Press 1 Byte Send Selected 1 Byte Value on Short Press 1 Byte I...

Page 27: ...tch 0 1 Out Btnx Two Objects Short Press 0 1 1 Bit Generic Control 1 Byte I C W T DPT_Value_1_Ucount 0 255 Out Btnx Room State 0 Normal 1 Make up room 2 Do not disturb 1 Byte I C W T DPT_SceneNumber 0...

Page 28: ...art 0 1 Out External Proximity Detection 1 Detection 63 1 Bit C T DPT_Start 0 1 Out Proximity Detection Send 1 when Proximity is Detected 64 1 Bit C T DPT_Bool 0 1 Out Luminosity 1 Bit 0 Over Threshol...

Page 29: ...n and send us your inquiries about Zennio devices https support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio...

Reviews: