BIN 44 / 4X / 2X
Universal Interface with Binary Inputs
and/or LED Lighting & Electronic Relay Outputs
ZIO-BIN44 ZIO-BIN4X ZIO-BIN2X
U
S
E
R
M
A
N
L
Application program version: [1.1], [1.2]
User manual edition: [1.2]_a
www.zennio.com
Page 1: ...X 2X Universal Interface with Binary Inputs and or LED Lighting Electronic Relay Outputs ZIO BIN44 ZIO BIN4X ZIO BIN2X USER MANUAL Application program version 1 1 1 2 User manual edition 1 2 _a www ze...
Page 2: ...1 Introduction 4 1 1 BIN 4 1 1 1 BIN 44 4 1 1 2 BIN 4X 4 1 1 3 BIN 2X 5 1 2 Installation 6 2 Configuration 8 2 1 General 8 2 2 Inputs Outputs 10 2 2 1 BIN 44 10 2 2 2 BIN 4X 2X 10 2 2 3 Binary Input...
Page 3: ...nio com Technical Support http support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 1 _a Application program changes Optimisation of the binary inputs electronic relay control and heartbeat...
Page 4: ...and switches or to operate low current relays e g heating system relays The BIN product family also incorporates the Heartbeat function which consists in sending a periodical still alive notification...
Page 5: ...4X 2X http www zennio com Technical Support http support zennio com 5 1 1 3 BIN 2X 2 input output channels freely configurable as Binary inputs LED Lighting Output Electronic Relay Control Heating Ac...
Page 6: ...ince it is entirely powered through the KNX bus Figure 1 Element diagram The main elements are described next Prog Test Button 2 a short press on this button sets the device into the programming mode...
Page 7: ...ennio com 7 To obtain further information about the technical features of BIN 44 4X 2X and on security and installation procedures please refer to the Datasheet of the device bundled with the original...
Page 8: ...neral From this screen it is possible to activate deactivate all the required functionality Figure 3 Default configuration BIN 44 Start up Delay 0 255 1 sets a delay after the initialisation so the de...
Page 9: ...xplained in later sections of this document Figure 4 Default configuration BIN 4X Heartbeat Periodic Alive Notification enabled disabled lets the integrator incorporate a one bit object to the project...
Page 10: ...els each of them configurable as a Binary Input See section 2 2 3 LED Lighting Output See section 2 2 4 Electronic Relay Control Heating Actuator See section 2 2 5 2 2 3 BINARY INPUT Please refer to t...
Page 11: ...the normal mode and for the night mode if required ETS PARAMETERISATION A general Configuration tab for the LED Outputs function is provided once at least one output has been configured as a LED Light...
Page 12: ...ve after an ETS Download 1 bit Object enabled disabled when marked it will be possible to switch the mode by writing to a binary object LED Brightness Mode The parameter Value 0 Normal 1 Night 0 Night...
Page 13: ...ific trigger object is received ETS PARAMETERISATION A specific Configuration tab is provided for each enabled LED output It contains the following parameters Figure 8 Ouput X LED Lighting Configurati...
Page 14: ...0 the LED will switch to the on state while the value 1 will switch it off LEDx Timer binary when it receives the value 1 the LED timer function will start while the value 0 will stop it LEDx Flashin...
Page 15: ...1 Bit C T DPT_UpDown 0 1 Ix Short Press Move Up Shutter Sending of 0 Up 1 Bit C T DPT_UpDown 0 1 Ix Short Press Move Down Shutter Sending of 1 Down 1 Bit C T DPT_UpDown 0 1 Ix Short Press Move Up Down...
Page 16: ...ulse Counter Counter Number of Pulses 3 9 15 21 1 Byte I C W DPT_Scaling 0 100 Ix Short Press Shutter Status Input 0 Top 100 Bottom 1 Byte I C W DPT_Scaling 0 100 Ix Short Press Dimming Status Input 0...
Page 17: ...s C T 9 xxx 671088 64 670760 96 Ix Long Press Constant Value Float Float Value 2 Bytes C T DPT_Value_2_Ucount 0 65535 Ix Long Press Constant Value Integer 0 65535 1 Byte C T DPT_Scaling 0 100 Ix Long...
Page 18: ...26 1 Byte O C T R DPT_Scaling 0 100 HC Max Control Value Output 0 100 49 27 1 Byte I C W DPT_Scaling 0 100 HC Max Control Value Input 0 100 52 64 76 88 30 42 1 Bit I C W DPT_Enable 0 1 HCx Lock 0 Unlo...
Page 19: ...ol Value 1 bit Status 0 Off 1 On 60 72 84 96 38 50 1 Byte I C W DPT_Scaling 0 100 HCx Control Value 1 byte 0 100 61 73 85 97 39 51 1 Byte O C T R DPT_Scaling 0 100 HCx Control Value 1 byte Status 0 10...
Page 20: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...