TheWPserieshasbeenapprovedwithaflowsensitivityclassU0/D0.
However,toachievethebestmeasurementresults,werecommend
observingnationalregulationsandrecognisedrulesoftechnology.

 

ForWPseriesisrecommendedastraightinletsectionofatleast3xDN.

 

Ideally,atleast2xDNshouldbeavailableastheoutletsection.

 

Beforeinstallingthemeter,thepipingmustbethoroughlyflushedout.

 

Thepipediametershouldnotbereduced,directlyinfrontandbehind
themeter.

 

Flangegasketsmustnotextendintothepipe.

 

Itmustbeensuredthattheflowdirectionofthemetermatchesthatof
thepipe.

 

Valvesorotherflowregulatorsshouldbeinstalled,wherepossible,
behindthemeter.

 

Themetershouldbeinstalled,wherepossible,atthehighestpointof
thepipeinstallationsothatairbubblesarenotabletoforminthemeter
andthepipeisalwayscompletelyfilled.

 

Ifnecessary,themetershouldbeprotectedbyacorrespondingfilter,
sothatnoforeignparticles,suchasstonesorsand,areflushedintothe
measuringinstrumentandcausedamage.

 

Themetermustbeprotectedagainstpressuresurgesinthepipenet

-

work.

 

Themaximumwatertemperaturemustnotexceedthepermissible50
°Cforcoldwater.

 

Inordertopreventdamagetothemeasuringinsertcausedbypressure
surges,thepipemustbeslowlyfilledfollowinginstallation.

Product description

BulkwatermetertypeWoltmanWPD/WPHDforcoldwaterupto50°C.
BulkwatermetertypeWPDE/WPHDE(radiowatermeter)withfactory

 

assembledandparameterizedEDCradiomoduleforcoldwaterupto50°C.

Intended use

Forthemeasuringofdrinkingwaterupto50°C
Forthemeasuringofcleanindustrialwaterupto50°C

Scope of delivery

1watermeter,1instructionmanual,DeclarationofConformity

Remark

Thisinstallationmanualisintendedforqualifiedspecialistsonly.Basic
installationstepsarethereforenotdescribed.
Themeterreadingmustbemultipliedbyfactorx10,forthenominalsizes
DN150toDN300,thenominalsizesDN400andDN500byfactorx100.

Permissible installation positions

TheWPseriesisintendedforinstallationinthehorizontalandvertical
positions.

 

Itmustbeensuredthatthemeterisinstalledinade-energisedstate
inthepipe.Inthecaseofaninstallationthatisnotde-energised,the
housingofthemeasuringinstrumentcanbedamagedandwatermay
escape.

 

Thepipelinepressuremustnotexceedthemaximumworkingpressure
ofthemeter,asthiscanleadtoleaksanddamageofthemeter.

 

Topreventthedisassemblyofthemeterwerecommendtosecurethe
connectioninterfacewithasafetydevice(adhesivelabel,seal,etc.).

 

AllserieshasbeenapprovedwithaflowsensitivityclassU0/D0(noinlet
outletsectionrequired).

 

Allseriesarenotapprovedforbackflowmeasuring.

 

Installation instructions for the replacement of the metrological unit

 

Theexchangeofexchangeablemetrologicalunitsmeasuringinsert
shouldonlybeperformedbytrainedspecialiststaff.

 

Beforechangingthemeasuringinsert,thepipemustberinsedcarefully
shutoffthepressuresideandemptythepipe.

 

Thecomplianceoftheinterfacesmarkingonthemeasuringandatthe
specifiedinterface(body)mustbechecked.InterfaceWP1forDN40–
150andtheinterfaceWP5forDN200–300.

 

Afterdisassemblyofthemeasuringinsertoldgaskets/sealsmustbere

-

moved.Thesealingsurfacesmustbecleanedandcheckedfordamage.

 

Itisimportanttoensurethattheinletareaisfreeofdeposit,beforea
newmetrologicalunitisinstalled,becauseasthesecanleadtodevia

-

tionsofthemeasurementresult.

 

Useonlythegenuineseals,whicharedeliveredtogetherwiththe
measuringinsert.Thesehavetobecheckedpriortoinstallationfor
damageandfit.

 

Whenusinglubricants/assemblypastese.g.fortheseals,itmustbe
ensuredthatthesearesuitableforcontactwithdrinkingwater.

 

Tightenthescrewsofthemeasuringunitevenlycrosswise(M12:DN40–
DN125=60Nm;M16:DN150–DN300=85Nm).

 

Topreventthedisassemblyofthereplacablemeasuringinsert,itmust
beconnectedwiththeconnectioninterface(housing)byasealingwire.

Thedeclarationofconformityisincludedinthedelivery.Thelatestinforma

-

tiononthisproductcanbecalledupfrom

www.zenner.com

WPD/WPHD/WPDE/WPHDE