FlushMaster Solo Installation & Maintenance Instructions - 87278 - January 2011

 End of life disposal

The use of this crossed out wheeled bin logo indicates that this product needs 
to be disposed of separately to any other household waste. 

Within each of the European Union member countries, provisions have been 
made for the collection and recycling of unwanted electrical and electronic 
equipment. Outside of the EU it will be necessary to dispose of this product at 
your local community waste collection or recycling centre. 

In order to help preserve our environment we ask that you dispose of this 
product correctly. Please contact your local city council for collection centre 
details

Summary of Contents for FlushMaster Solo 42214

Page 1: ...enance Instructions 87278 January 2011 Page 1 of 12 Installation and Maintenance Instructions FlushMaster Solo 42214 FlushMaster Solo AC Mains Solenoid WS005 Water Saver Urinal Flushing System Keeps U...

Page 2: ...5 Connect Latching Valve Cable 6 Set Flush Timing 7 Maintenance Instructions 8 Completing Installation 8 Problem Solving 9 End of life disposal 10 Notes pages 11 Warranty Information 12 99026 Zenith...

Page 3: ...d should never be installed outdoors or exposed to the elements of nature This unit must not be positioned in an area that may be cleaned by a water jet This unit must not be cleaned with a water jet...

Page 4: ...break to the top of the urinal sparge pipe in place of a cistern as shown in the diagram Locate as high as possible Do not use sealing tape in the air break joints The fittings in the latching valve w...

Page 5: ...er hole in the ceiling Use the inbuilt clips to fasten the sensor housing in place when inserted into the hole If any of the cable connecting the sensor to the latching valve is visible shield it with...

Page 6: ...the circuit board by first removing the plug from the board Lift plug directly upwards and hold plug so fixing screws are facing you Thread the cable through one of the holes in the the sensor lid Sec...

Page 7: ...second delay and it will flush for the time you have set on the rotary switch The unit can only be used with the supplied power pack Mount the sensor away from lights hot pipes ceiling transformers an...

Page 8: ...rom latching valve shaft Carefully undo the 4 screws retaining the valve housing When the last screw is about to be released grip the valve body and top section as it is spring loaded Carefully separa...

Page 9: ...hes for a short period of time Sensor duration time set incorrectly Reset flush dial to a higher number See page 7 Sensor not active Wrong ceiling position Reposition sensor See page 5 No Power Faulty...

Page 10: ...Within each of the European Union member countries provisions have been made for the collection and recycling of unwanted electrical and electronic equipment Outside of the EU it will be necessary to...

Page 11: ...11 of 12 NOTES WELS Ratings This system when tested with a Caroma Leda urinal achieves a 4 Star WELS rating In order to maintain the WELS ratings for alternative urinals the flushmMaster must be set...

Page 12: ...s Distributor This warranty does not cover damage resulting from non operation of the system the use of non authorised parts or consequential damage to any other goods furnishings or property Zenith d...

Reviews: