Read These Warnings First

Tapware 

#

Quick Installation Guide

Please read all installation requirements, installation procedures and
precautions before installing any Z

enith 

Tudor water heater.

Never attempt to install any Z

enith

 Tudor water heater without reading all of the

applicable instructions.

Z

enith

 Tudor water heaters are open outlet (vented) water heaters and must not

be installed in the same way as mains pressure type water heaters.

The outlet from any Z

enith

 Tudor water heater must be connected directly to an

outlet spout on the sink and must not be obstructed by a tap or valve or in any
other way.

The water flow is controlled by a cold water tap connected before the water
heater. Cold water pushes hot water out of the tank when the cold water tap is
turned ON. Any such cold water tap should be labelled HOT.

This water heater must not be connected to more than one outlet.

All plumbing connections must be made in accordance with AS3500.

The heater is intended only for indoor use and should never be installed
outdoors or be exposed to the elements of nature.

Over-sink and under-sink models are NOT interchangeable.

Children should be supervised to ensure they do not play with the heater.

The heater is unsuited for use by children or infirm people without supervision.

If the power supply cord is damaged it must be replaced by a Z

enith

 Service

Provider or a qualified electrician.

Do not remove the cover of the heater under any circumstances without first
isolating the heater from the power supply.

Outlet temperature should never be set to less than 60

°

C without due regard to

regulations governing the storage temperature of hot water.

!

Step One

Install approved vented tapware 
see page 3

Step Two

Position heater <1000 mm from  tap
see page 4

Step Three

Fasten heater to wall
see page 4

Step Four

Connecting
see page 4

Step Five

Commissioning
see page 4 
before turning power on

Tudor Heater

Isolation valve

Cold Water Supply

Flow Restrictor

Page 2

Z

enith

 Tudor - Installation & Operating Instructions - 81333 - July - 2004

Summary of Contents for 216666666

Page 1: ...lo vented mixer tap for 21010 21030 99050 Hero vented mixer tap for 21010 21030 Installation Operating Instructions 21600 Zenith Tudor 5 Litre over sink water heater 21620 Zenith Tudor 10 Litre over s...

Page 2: ...outlet All plumbing connections must be made in accordance with AS3500 The heater is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature Over s...

Page 3: ...ible tubes are firmly attached to the base of the tap body 2 Flush water supply pipes thoroughly to remove any silt or fines 3 Fasten the tap body to the sink using the bolt plate system provided 4 Co...

Page 4: ...must also be fitted with an isolation valve on the cold water side A valve is not supplied with the heater and must be supplied and fitted by the installer Under sink models must be installed with app...

Page 5: ...erlaod Check power supply Contact Zenith No water No supply Blockage Faulty thermostat Faulty cut out Check water supply Contact Zenith No indicator Faulty LED Faulty connection Contact Zenith Zip Tud...

Page 6: ...mperature control will maintain stored water temperature over 5 C to prevent freezing and damage to the water heater The same protection does not extend to connecting pipework or fittings Safety Cutou...

Page 7: ...erse is applicable Attach the thermostat to the plastic upright Reconnect the two electrical terminals It does not matter which way around the connections occur Ensure the remaining capillary coil is...

Page 8: ...s are payable by the customer other than any mileage or travelling time charges incurred by a Zenith Service Provider or the cost of removal cartage and re installation of any component of the applian...

Reviews: