10
EA1400/1600 Installation & User Manual
A100K11939
The mains power cable should be 3 x 1 mm
2
rated for 500 VAC.
WARNING
Do NOT disconnect the third (yellow/green) wire in the power plug. This wire grounds the amplifier’s
chassis to prevent a possible shock hazard. If an adapter is used to connect the plug to an ungrounded
outlet, make sure that the amplifier’s chassis is connected to the vessel’s central ground. In a rack
installation, the amplifier’s grounding point is connected to the rack frame.
3.5. Input Connection
The line inputs are balanced, accepting 0.5 -1.5 Vrms signal over 9 K ohm.
The signal source is connected between pin 1 and 2, and the wire shield is connected to pin 3.
If the signal source is unbalanced, connect the signal wire to pin 1 and the neutral wire to pin 2.
If two or more amplifiers are using the same audio signal, connect the SOURCE terminals on the first
amplifier to the corresponding IN terminals on the next amplifier.
The input levels must be adjusted individually (use VOLUME potentiometer on each amplifier unit).