TD 92022GB
2002-11-13/ Rev. A
Installation Guide
H/U952T Terminal Transmitter
7
3.6
Connection of Supply Voltage
• Connect supply voltage to connector J102 screw 1 and 2. See also the System
Installation document, under
Power Supply
.
Figure 10. Power supply connector.
3.7
Coax Connection to Antenna
• Connect the antenna coax to the antenna output connector located at the upper right
of the transmitter, see
• To prevent water from running along the antenna cable and entering the transmitter,
let the cable form a loop downwards. See
below.
Figure 11. Preventing water to run along the cable and entering the transmitter.
For assembly of the coax connector to the cable, see
.
3.8
Connection to Slave Transmitter
If the transmitter is to drive a slave transmitter, slave driver U952DR (UHF systems) or
power divider MPT-50 (HF systems) is to be installed between the transmitter and the
slave. The slave driver or power divider is connected to the antenna output, in series with
the coax from the antenna.
J102
3
+12V
4
GND
1 +12V
2 GND
Supply voltage-in
Supply voltage-out
H/U952T
Transmitter