background image

Network Speakers

Mounting & Installation Manual

A100K12150

ELSII-10HM
ELSII-10LHM
ELSII-10PM
ELSII-10WM
ELSIR-10CM

EN

Summary of Contents for 1023300011

Page 1: ...NetworkSpeakers Mounting Installation Manual A100K12150 ELSII 10HM ELSII 10LHM ELSII 10PM ELSII 10WM ELSIR 10CM EN...

Page 2: ...jectorSpeaker 10W Ethernet Microphone 1023302330 ELSII 10WM NetworkCabinetSpeaker 10W Ethernet Microphone 1023300011 ELSIR 10CM NetworkCeilingSpeaker 10W Ethernet Microphone This document serves as a...

Page 3: ...s plugs or screws other than those specified by Zenitel they may not be able to hold the weight of the product and this may cause a safety hazard When drilling holes in wall pole or plate make sure yo...

Page 4: ...wall etc Head diameter 12 5 M6x 38 or45 mm 2x Nylon plugs 2x M6 Screws Mounting Plate or Column recommended screws M6 x 20 or 25 with Philips head DIN7985 or Torx head diameter 12 mm 2x M6 Screws 1 Un...

Page 5: ...rophone and speaker wires are correctly connected Speaker Red Yellow Microphone White Black 7 1 Reattach the back plate To maintain the IP 66 rating on the speaker use a tightening torque of 0 8 Nm 2...

Page 6: ...Com Edge Mode ELSII 10HM Value Weight 1 65kg Dimensions HxWxD 144x186x207mm ELSII 10LHM Value Weight 1 9 kg Dimensions HxWxD 274x200x348mm Technical specifications Value IPRating IP66 Relativehumidity...

Page 7: ...therefore be mounted at a hight of 1 5 3m with the microphone turning down for optimal placement The speaker can be placed in the range of 1 5 3 5 meters 30 8 x 2 152 1 The speaker can be mounted bot...

Page 8: ...l etc Head diameter 12 5 M6 3x 38 or 45 mm Mounting Plate or Column recommended screws M6 x 20 or 25 with Philips head DIN7985 or Torx head diameter 12 mm 2x Nylon plugs 2x M6 Screws 2x M6 Screws 4 Wh...

Page 9: ...end Cable Gland M20 clamping range of 5 12 mm 8 1 Attach and fasten the lid 2 Make sure to tighten the cable gland sufficiently to attain IP 66 rating for watertightness but be aware of plastic materi...

Page 10: ...you need to configure SIP Mode ICX AplhaCom Edge Mode Technical specifications Value Weight 2 35 kg Dimensions HxWxD 176x201x160mm IPRating IP66 Relativehumidity 95 notcondensing Operatingtemperaturer...

Page 11: ...cement of the speaker microphones ability to detect voices Unscrew the ELSII 10WM from the mounting bracket and place the bracket on the specified location The speakers can be mounted both horizontall...

Page 12: ...iameter 12 mm 2x Nylon plugs 2x M6 Screws 2x M6 Screws 4 Fasten the speaker to the mounting bracket Then remove the back plate on the speaker 5 1 Run an Ethernet cable through the cable gland on the b...

Page 13: ...are of plastic material limitations In order to ensure the required minimum degree of protection the cable glands must be tightened securely When tightening the cap nut of a cable gland a suitable too...

Page 14: ...sulationmaterial Aluminium Mounting Aluminium UShapedBracket CableGland 1xM20 20mm 5 ELSIR 10CM ELSIR 10CM Mounting Installation of ELSIR 10CM Mount the speaker in the ceiling at the maximum height of...

Page 15: ...s available through the ready made hole 1 Run the cable through the cable gland on the firedome and terminate the cable to a RJ45 connector 2 Insert the Ethernet cable into the TKIS Kit Ethernet port...

Page 16: ...ning the cap nut of a cable gland a suitable tool shall be used to prevent the gland from twisting 6 Insert the speaker into the opening Make sure the side clamps are held in an upright position 7 Use...

Page 17: ...e does not legislate that Zenitel as a producer shall collect end of life WEEE This end of life WEEE should be recycled appropriately by the owner who should use proper treatment and recycling measure...

Page 18: ...therequirements inNS ENISO9001 Zenitelreservestherighttomodifydesignsandalterspecificationswithoutnotice ZENITELPROPRIETARY Thisdocumentandits supplementingelementscontainZenitelorthird partyinformati...