Zener ECODRIVE 8000 AQ08300 Instruction Sheet Download Page 2

Document: IM00156 Rev A 

Printed: 15-Mar-18 

 

 

 

Installation Notes: 

 

 

Refer to the ECODRIVE supplement manual IM00130

 

for details on installing & wiring the ECODRIVE 8000 and 

auxiliary equipment. 

 

The blocking diode(s) must be installed unenclosed and in a location away from direct sunlight or other heat 

sources. The blocking diode(s) should be installed on the framework of the PV array and behind the solar panel(s). 

 

The blocking diodes must be installed by a qualified & licenced electrical person with the required solar 

accreditations. 

 

The blocking diode enclosure must be properly earthed. Earth with a 

minimum conductor size of 4mm

2

 

 

It is the installer’s responsibility to assure that all earthing connections are 
properly made and meet all local rules and regulations. 

 

Connections to the Blocking Diode must be made using the same 
brand/model connector (see specifications for details) 

Failure to install blocking diodes when required 

may result in equipment damage and will void any 

equipment warranty 

Diagram: 

Blocking diode wiring for a 2x string solar array 

Reviews: