Zemic BM24L10 Series Installation And Operation Manual Download Page 4

Type BM24L10 EHEDG Load Cell

  

 

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.

 

Zemic Europe B.V.

 

 

 

T: +31 76 50 39480

 

Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1

 

[email protected] 

Page 2/7

 

 

www.zemiceurope.com

 

1.5 General Risk of Non-Compliance with Safety Instructions

 

The sensor is designed to be reliable, but may be at risk if it is improperly installed, positioned and

 

operated, or if it is installed, positioned and operated by untrained personnel. Any personnel

 

related to operation or maintenance must read and understand the installation instructions,

 

technical specifications and cleaning instructions carefully, particularly the technical specifications

 

and cleaning method, otherwise it may lead to damage of the sensor(s), and may result in property

 

damage and/or injuries of personnel nearby.

 

 

1.6 Product Changes and Modifications

 

For design and safety reasons, users are prohibited any change or modification to the sensor unless

 

expressly approved by ZEMIC. We are not responsible for any loss caused by any change or

 

modification without permission. Any modification without permission immediately voids warranty.

 

 

2 Installation

 

2.1 Mounting Dimensions

 

 

 

2-1 Product Installation and Loading Drawing 

Note:

  

1) The loading point is allowed to have appropriate deflection angle, but within 5°. 

 

2) The customer's bottom mounting plate shall have at least a bevel of 3° ~ 5° for liquid discharge/draining. 

50Nm / 92 Nm 

50Nm / 92 Nm 

Summary of Contents for BM24L10 Series

Page 1: ...ct to change without notice and do not constitute any liability whatsoever Zemic Europe B V T 31 76 50 39480 Nr 2023 11 BM24L10 Installation and Operating Manual Rev1 info zemic nl www zemiceurope com...

Page 2: ...nts 1 Safety Instructions 1 1 1 Specific Condition of Use 1 1 2 Safety Loading 1 1 3 Used as Equipment Unit 1 1 4 Additional Safety Precautions 1 1 5 General Risk of Non Compliance with Safety Instruc...

Page 3: ...equirement It must be noted that when multiple load cells are mounted on single scale the load on every single load cell is not always evenly distributed and care must be taken not to overload them 1...

Page 4: ...cations and cleaning instructions carefully particularly the technical specifications and cleaning method otherwise it may lead to damage of the sensor s and may result in property damage and or injur...

Page 5: ...mm 5t 10t 8 8 20t 12 9 50 Nm 92 Nm Bottom 15mm 2 2 Pre Cautions During the sensor installation process the following matters should be noted 1 Operate the sensor carefully do not to bump or scratch th...

Page 6: ...commended cleaning methods are as follows 1 Dry cleaning using tools including rag and or a soft brush 2 Wet cleaning using wet cloth chemicals low pressure clean water 3 2 Pre Cautions The operator s...

Page 7: ...interfaces need to be sealed with sealing washers and there must be no threads exposed in the installed configuration of the machine feet The rubber sealing ring that is used to seal the space betwee...

Page 8: ...sensor cable in parallel with the power circuit and control circuit on the installation site If this is necessary the sensor cables need to be shielded and protected 5 Technical Specifications Table...

Page 9: ...without notice and do not constitute any liability whatsoever Zemic Europe B V T 31 76 50 39480 Nr 2023 11 BM24L10 Installation and Operating Manual Rev1 info zemic nl Page 7 7 www zemiceurope com 6 O...