61
FEATURES
ZELMER cooker hood is used to extract cooking fumes. It requires to install a duct
extracting air to the outside. The length of the duct (most commonly a tube Ø 150 or
Ø 120 mm) should not exceed 4-5 m. After installing the active-coal filter which is avail
-
able in the sales network, the cooker may operate as an odor absorber. In this case it
is not required to install the duct extracting the air to the outside, however it is recom
-
mended to install an air exhaust fin.
It is equipped with an independent lighting and an extract fan with three speed settings.
The cooker hood is designed for a permanent installation on a vertical wall above the gas
or electric cooker.
The cooker hood is a I class appliance equipped with a cord having a grounding wire with
a grounding plug. Plug the cooker hood only to a grounded AC electrical outlet with the
voltage corresponding to the voltage indicated on the rating plate.
PARTS
The cooker hood is composed of the fol
-
lowing elements (fig. 1):
The hood body C equipped the with
●
lighting and the fan unit.
Decorative masking cover comprising
●
of: the upper A and lower B chimney.
Cooker hood wall hanger D and mask
-
●
ing cover upper hanger E.
Air exhaust fin F.
●
Reduction adaptor.
●
A set of rawlplugs.
●
ASSEMBLY
In order to assemble the cooker hood:
1. Fix the wall hanger D at an appropriate height.
2. Hang the hood body C on the hanger D.
3. Connect the cooker hood to the ventilation duct.
4. Plug in the cooker hood.
5. Fix the wall masking cover upper hanger E at an appropri
-
ate height.
6. Install the telescopic chimney masking cover column A
and B.