15
UNIX 5000 Full Face Mask
Instructions for Use
RE 2568-563-05795731-2013
These Instructions for Use serve to explain the design, principle of
operation, and the use of UNIX 5000 Full Face Mask (hereinafter referred
to as the Mask).
Read this manual carefully and follow the rules of operation.
1 Intended Use of the Mask
1.1. The Mask is used as a facial part in personal respiratory
protective equipment (RPE) to reduce the risk of exposure of harmful
factors to a human.
The Mask serves to supply cleaned air to human respiratory system
and at the same time to protect the person’s face and eyes against
contact with hazardous substances.
1.2 The Mask can be used in all climatic zones at temperatures
ranging from 40 °С below zero to 40 °С above zero.
1.3 In terms of intended use and protective efficiency, the Mask
meets EN 136:1998+AC:2003 СL 2 requirements.
ATTENTION!
1.4 The multiplicity of reducing the concentration of gases, vapors
and aerosols with filters is 2000.
1.5 It is prohibited to use the mask in conditions of possible
lack of oxygen (less than 17% by volume) in the air (for example, in
tanks, cisterns, wells, etc. isolated rooms of this type), with unknown
composition and concentrations of harmful substances, as well as for
protection against low-boiling poorly absorbed organic substances
(methane, ethane, butane, ethylene, acetylene, etc.)
1.6 It is prohibited to use defective masks.
1.7 It is prohibited to disassemble and assemble of the Mask on
one’s own.
1.8 It is prohibited to put on and put off the Mask in explosive
atmosphere.