background image

ii

HDMI5 Component Video Switch 

1

HDMI5 Component Video Switch

The RS-232 Port .............................................................. 1

K.I.S.S.™ (Keep It Simple Serial™) .................................... 2

The K.I.S.S.™ Command Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Using Bitmapped Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Command Checksums and CRC-8 Checkcodes . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Clearing the Command Buffer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
The Response Strings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Response String Checksums and CRC-8 Checkcodes . . . . . . . . . . . . . . . . . . . . . .6
Master / Slave and Asynchronous Modes of Operation  . . . . . . . . . . . . . . . . . . .7
The Master / Slave Mode of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
The Asynchronous Mode of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Checksums and CRC-8’s ................................................. 10

Checksums and CRC-8 Checkcodes Defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Differences between a Checksum and a CRC-8 Checkcode . . . . . . . . . . . . . . 10
Source Code Example of Calculating a Checksum . . . . . . . . . . . . . . . . . . . . . . 11
Source Code Example of Calculating a CRC-8 Checkcode . . . . . . . . . . . . . . . 12

HDMI5 Command Ref. ................................................... 14

The HDMI5 K.I.S.S.™ Command Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Error Response Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
The HDMI5 Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Version Query . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Power Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Output Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Front Panel Light Intensities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Save Power On Default Settings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Query Last IR Code Received . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Set Learnable IR Command Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Front Panel Button Emulation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Query Status  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Control Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Extended Control Settings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Input Equalization & Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Switching Delays  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Relay Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Relay Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Table of Contents

The RS-232 Port

The RS-232 port on the HDMI5 is the same format, and pinout, as a PC-modem, and uses the 

same type of cable as a standard serial modem would, which is a standard straight through 

cable. Do not use a cable that is marked as a “Null Modem” cable.
The HDMI5 can also be used with any USB to RS-232 conversion cable, these are all typically 

straight through cables.
The RS-232 port is a female type DE-9 connector (sometimes mistakenly referred to as a DB-9 

connector) with the following pinout:

5   4   3   2   1

9   8   7   6

 

Pin definitions:

    1 - No Connect   6 - No Connect

    2 - TX        7 - No Connect

    3 - RX        8 - No Connect

    4 - No Connect   9 - No Connect

    5 - GND

 

The port settings used by the HDMI5 are:

    Baudrate:  9600

    Data Bits:  8

    Stop Bits:  1

    Parity:    NONE

Summary of Contents for HDMI5

Page 1: ...Rev 1 06 28 2007 Digital Video Switch 1 2 3 4 5 SEL A1 A2 HDMI5 Supplement to the HDMI5 User Guide Home Theater Solutions...

Page 2: ...el Light Intensities 16 Save Power On Default Settings 17 Query Last IR Code Received 17 Set Learnable IR Command Codes 18 Front Panel Button Emulation 19 Query Status 21 Control Settings 22 Extended...

Page 3: ...lue defaults to the current setting leaving the value unchanged The K I S S Continued space before the comma is optional Most commands can be queried for their current settings by substituting the for...

Page 4: ...owed before the and characters but NOT after them The checksum must immediately follow the character and a CRC 8 checkcode must immediately follow the character anything else including whitespace will...

Page 5: ...CR LF Notice that in the first example a checksum was not appended to the LI command When issuing a command the checksum and CRC 8 codes are sent on a command by command basis Anytime a checksum or a...

Page 6: ...ughout the com munication sequence First the LI CR command was issued by the controller While looking for an Acknowledgement or Error Response string an unsolicited Query Response is received indicati...

Page 7: ...um and a CRC 8 Checkcode A CRC is capable of finding many more and different types of errors than a checksum can A good description of its capability is described in the above referenced articles but...

Page 8: ...r detection characteristics So x 8 x 6 x 3 x 2 1 101001101 14D hex Ignore X 8 01001101 4D hex Reverse bit order 10110010 B2 hex define CRC8_POLY 0xB2 polynomial mask define CRC8_INIT 0xFF initial valu...

Page 9: ...t at writing them will return Error 6 The Front Panel Button Emulation command with button code 0 can be used to exit the Setup Mode at which point the command can be re issued without an Error 6 resp...

Page 10: ...Restore all settings to their factory defaults There is no Response String for this command Note Any value given other than 246 will generate a range error Query Last IR Code Received This command al...

Page 11: ...iliary Relay 1 Toggle 9 Auxiliary Relay 2 Toggle 10 Discrete Power On 11 Discrete Power Off 12 Discrete Breakaway Off 13 Sequence through inputs 14 Discrete Audio Breakaway Select 15 Discrete Video Br...

Page 12: ...e HDMI5 Some extended button codes are Code Description 0 When Issued Exits setup modes 0 When returned by query No buttons have been pressed since last the query 100 Always toggle power like Power To...

Page 13: ...EEPROM XS settings Reset bits indicated in settings to 0 save in EEPROM XS Back up current settings into EEPROM XS Query for current settings XS Query for current settings Response String XS settings...

Page 14: ...urrent settings XE Query for current settings Response String XE settings Where settings is a bitmapped parameter Decimal Value 4096 2048 1024 512 256 128 64 32 16 8 4 2 1 Bit Position 12 11 10 9 8 7...

Page 15: ...and Ref Cont d HDMI5 Command Ref Cont d Where rly_n Relay number 1 or 2 state State of relay 0 Off 1 On 2 Toggle If present settings are backed up in EEPROM Relay Settings Setup the behavior of the re...

Page 16: ...input is set to 1 in the vid_msk or aud_msk parameter The time value given is how long a relay remains active after a input is selected that does not match a 1 bit in vid_msk or aud_msk Mode 4 Relays...

Page 17: ...Z E K T O R 12675 Danielson Ct Suite 401 Poway CA 92064 858 748 8250 www zektor com...