CLEANING INSTRUCTIONS - SOLENOID DRAIN VALVE
• Be sure dryer is depressurized or
...
isolation valve is closed.
• Disconnect drain body from filter stop.
• Loosen connector screw to allow the
electrical connector assembly to be
removed from the D.I.N. unit solenoid.
• Remove retainer nut and separate the
valve body from the D.I.N. unit solenoid.
• Unthread the plunger tube assembly in a
counter-clockwise direction until plunger
separates from valve body.
• Clean beveled washer, thread gasket,
spring assembly and strainer with soap
and water. Do
NOT
use solvents of any
kind, as failure to the seals will occur.
Be especially careful to clean the center
brass orifice and the rubber gasket orifice
on the orifice cup with a straight pin.
• Reassemble all drain components after the drain has been cleaned and inspected.
Reposition the orifice hole on the rubber gasket of the orifice cup in the line and
closest to the arrow indicated on the valve body.
• Reassemble valve and install in reverse order as described above.
SOLENOID VALVE DETAIL
18
FIGURE 4
DRAIN DETAIL