Pull line blowing in conduits (ø 18-50 mm) 

EZ50 Operating manual  version 11/2018 

page 22 / 24 

17. 

Technical Data EZ50  

Standard version for internal conduit diameters from 18 to 50 mm. 
 

Electrical data

 

as per country 

 

see type plate 

 
 

Weight

 

4 kgs 

 
 

Pull line

 

approx. 900 m/roll 

 
 

Dimensions  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Thermal circuit breaker 

 
 

Maximum air flow rate 

Blowing mode  

4  m³/h 

Suction mode 

4  m³/h 

 
 
We reserve the right to make technical modifications without notice.  

Summary of Contents for EZ.50

Page 1: ...STRINGING GUN OPERATING INSTRUCTIONS ...

Page 2: ...r Thank you for choosing a quality engineered ZEITLER product Our machines are built using modern production techniques and comprehensive quality assurance Every effort has been made to ensure your satisfaction and trouble free use of the machine Please contact either your dealer or us for any queries concerning your EZ50 ZEITLER AG Markus Zeitler ...

Page 3: ...ration 10 6 Inserting the pull line roll 11 7 Blowing mode with EZ50 12 8 Suction mode with EZ50 14 9 Cleaning 16 10 Storage16 11 Transport 16 12 Troubleshooting 17 13 Support18 14 Service and Maintenance 19 15 Main parts EZ50 20 16 Special accessories assembling and usage 21 17 Technical Data EZ50 22 18 Guarantee Legal Details 23 19 EC Declaration of Conformity 24 ...

Page 4: ...on such as local safety regulations standards and ordinances of for example Government Insurances Associations etc If you have not used this machine before Have your dealer or another experienced user show you how to operate your machine properly Minors should never be allowed to use this machine except for minors of more than 16 years and being trained under supervision during their apprentice Do...

Page 5: ...f accidents and damage to the machine If you have any question in this respect consult an authorized servicing dealer Never attempt to modify your tool in any way since this will increase the risk of personal injury ZEITLER AG excludes all liability for personal injury and damage to property caused while using unauthorized attachments You will find an updated list of all accessories and spare part...

Page 6: ... Used lines can also be used for other purposes or must be properly disposed of All relevant regulations and laws of the particular country must be complied with when disposing of old lines Lines that have already been used must not be used again in the cylinder for pull line of the Stringing Gun Personal protective equipment Wear proper protective clothing and equipment Clothing must be sturdy bu...

Page 7: ... kg 3 x Beads round Ø 11 mm in small container Art 100040 3 x Beads round Ø 13 mm in small container Art 100041 3 x Beads round Ø 16 mm in small container Art 100042 1 x Components Set A Art 100036 2 joints reduction 19 12 mm nozzle orange Ø int 9 5 mm 1 x Components Set B Art 100032 3 joints nozzle orange Ø int 16 mm plus nozzle orange Ø int 19 mm 1 x Special nozzle black for Ø int of 25 to 50 mm...

Page 8: ... 2 pieces Beads long Ø 17 mm Art 100027 Container for beads Art 100006 Handle Switch Art 100020 Front plate with ring Art 100019 Cylinder for pull line Art 100022 Line brake Art 100021 Electronic plate Art 100003 Motor 230 V 50 Hz Art 100004 Motor 115 V 60 Hz Art 100309 Parachute for conduits internal Ø 30 60 mm Art 100056 Box with shuttle assembly material Content 20 x screws with hole 2 x wrench...

Page 9: ...onduits ø 18 50 mm EZ50 Operating manual version 11 2018 page 9 24 Art 100330 Lubriball 22 mm Art 100280 Spray nozzle You will find an updated list of all accessories and spare parts in our online shop www zeitler ch en shop ...

Page 10: ...l water is actually left in the ducting never work in suction mode damage to the motor 9 Always keep the air intake opening screen free danger of overheating fire If any impurities are found in the screen remove them immediately 10 Never use the device if the mains cable is damaged Have faulty cables or plugs replaced immediately by the manufacturer or the importer Never pull the plug out of the m...

Page 11: ...e front plate A 4 Take out any remaining pull line 5 Carefully remove the plastic foil from the new line roll 6 Insert line roll so START label is visible 7 Remove START label and thread end of line through front plate B 8 Replace the front plate and close it with the bayonet catch 9 The correct positioned line roll must have a little clearance all around it 10 Blow out approx 5 m of line ...

Page 12: ...ull line max 2 to 3 cm shorten the overhanging end of the string or attach the bead D 9 Release line brake E 10 Insert the loop bead in the duct and place the nozzle 11 Start blowing without interruption during max 30 seconds thermal protection switch 12 Observe the uncoiling procedure in the pull line cylinder F 13 DO NOT block the air inlet grid on the rear of the device with clothing or body 14...

Page 13: ...Pull line blowing in conduits ø 18 50 mm EZ50 Operating manual version 11 2018 page 13 24 ...

Page 14: ... use joints if necessary C 8 At the other end of the duct where device is not in use position the assistant with a pull line roll in foil 9 Put the pull line roll in foil on the floor D 10 Make a small loop about 2 to 3 cm in the beginning of the pull line 11 Hold loop in duct for suction flow 12 Place the nozzle in the beginning of the duct 13 Start suction mode introduce line gradually by hand w...

Page 15: ...Pull line blowing in conduits ø 18 50 mm EZ50 Operating manual version 11 2018 page 15 24 ...

Page 16: ...reen 10 Storage If the device is not in use disconnect the mains plug Store the unit in its original case to protect it from damage with the Operating Instructions Protect the unit from moisture and dust Temperature range 0 40 C relative air humidity 40 to 90 11 Transport Transport the unit in its original carrying case making sure it is correctly closed If the unit is dispatched by any mode of tr...

Page 17: ...m end of conduit Cap on conduit outlet Conduit badly kinked try from the other end or try suction mode Air intake screen blocked Correct nozzle diameter Line not uncoiling Line brake released Line roll has necessary clearance Grid air inlet blocked by clothing object Grid air inlet dirty Too many joints connected Cap on conduit outlet Blow out approx 5 m of line to check uncoiling you may pull man...

Page 18: ...min Is there water in the tube Oyes Ono Odon t know Have you tried to blow from opposite Oyes Ono Tube occupied Oyes Ono How far did you blow the pull line __________ meter Is the tube diameter identical along the way Oyes Ono More useful information ______________________________________________________________ ______________________________________________________________ _______________________...

Page 19: ...n in this respect consult an authorized servicing dealer In the absence of alternative arrangements the manufacturer s or importer s service will include restoration to the original as delivered condition restoration to the original equipment included in the scope of supply The user is responsible for all damage caused by non observance of the safety precautions and operating and maintenance detai...

Page 20: ...Pull line blowing in conduits ø 18 50 mm EZ50 Operating manual version 11 2018 page 20 24 15 Main parts EZ50 ...

Page 21: ...ith normal ducts and flexible pipes also for deformed dirty or dusty ducts diameter corresponds to 70 if inner duct diameter Disc white suitable to expel condensation or storm water possibility to calibrate duct diameter corresponds to 90 if inner duct diameter Parachute able to pass narrowings up to ø 30 mm to be used at extremely dirty pipes and even in pipe systems with different diameters migh...

Page 22: ...Standard version for internal conduit diameters from 18 to 50 mm Electrical data as per country see type plate Weight 4 kgs Pull line approx 900 m roll Dimensions Thermal circuit breaker Maximum air flow rate Blowing mode 4 m h Suction mode 4 m h We reserve the right to make technical modifications without notice ...

Page 23: ...from reference properties which are immaterial as regards the value and suitability for use of the device 4 The rectification of faults we recognise as being under guarantee will take place in such a way that we will repair the faulty device without charge or replace it with a device in perfect condition if necessary a subsequent model according to our choice Any devices or parts that have been re...

Page 24: ... gun Model EZ50 Conform to the specification of Directives SECURITY EN 60745 1 2009 EMV EN 55014 1 2006 A1 2009 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 AN 61000 3 3 2008 EMF EN 50366 2003 A1 2006 Following the provisions of directives 2006 95 EC 2004 108 EC 2002 95 EC 2002 96 EC Définition 2009 Person authorized to arrange technical information Markus Zeitler Zeitler AG 6206 Neue...