background image

7

3.  Activate the live view of your camera.
4.   Set the distance of 1.5m on the lens focus ring and use the zoom level at 45mm. 

This setting must not be changed during the adjustment process.

5.   Set the largest aperture of T 2.6 on the aperture ring.
6.   Obtain maximum image sharpness on the live view by varying the distance 

between the test chart and the camera. Set the live view to maximum 
magnifi cation in order to obtain the highest level of precision when checking 
image sharpness.

7.   Now re-measure the distance between the image plane mark on the camera body 

and the test chart (= the actual distance).

 

 

8.   If the distance has changed, the fl ange focal distance of the lens must be 

adjusted by using the colored shims.

 

9.   You fi nd the differences between the actual and the theoretical distance to the 

test chart in the appendix (page 10) to calculate the resultant change in the 
fl ange focal distance.

10.   Now remove the lens from the camera after you have defi ned the number and 

thickness of the shim(s) needed.

11.  Remove the EF mount and EF adapter ring from the lens barrel (cf. section C 2-4). 

Summary of Contents for Lightweight Zoom LWZ.2

Page 1: ...1 Carl Zeiss Lightweight Zoom LWZ 2 Mount Change Instructions...

Page 2: ...and future use in any situation and for a wide range of camera platforms With the three different mounts available PL EF and MFT mount there is no need for adapter solutions anymore Exotic glass mater...

Page 3: ...d clean cotton cloth The ZEISS lens cleaning kit will give superior results and is highly recommended for this purpose When matching the lens ensure that the colored shims lie on top of each other in...

Page 4: ...rews of the silver EF mount with a T6 torque wrench and place the mount and the screws on one side The size of the black inner ring is securely fastened to the EF mount at the factory 3 Remove the tor...

Page 5: ...ow place the PL mount on the lens in such a way that the groove on the underside of the PL mount fits over the silver screw on the lens barrel Tighten the torx screws with the T6 torque wrench using a...

Page 6: ...nce The lens already contains shims when delivered Please use for shimming only the shim set for the Lightweight Zoom LWZ 2 It is highly recommended to handle the shims carefully as they can easily ki...

Page 7: ...precision when checking image sharpness 7 Now re measure the distance between the image plane mark on the camera body and the test chart the actual distance 8 If the distance has changed the flange fo...

Page 8: ...m on the lens in such a way that the groove on the adapter ring is facing to the index ring on the lens barrel Tighten the screws of the EF adapter ring and then the screws of the EF mount using a tor...

Page 9: ...to best focus of 1530mm is measured A light blue shim 0 032mm thick must therefore be added to the lens groove Note Any combination of shims is possible to achieve the required thickness and therefore...

Page 10: ...Feet distance scale Focal length setting mm 45 Feet distance scale mm 45 Distance to test chart mm 1500 Distance to test chart ft 5 Object distance at best focus mm Change of total shim thickness mm...

Page 11: ...49 755 Colored Shims LWZ 2 Set 1855 032 Technical Information Focal length range 15 5 45 mm Focal length ratio 3 1 Aperture T2 6 T22 Number of aperture blades 9 Close focus 0 45 m 18 inches Angle of f...

Page 12: ...EN_10_070_718I Printed in Germany CZ IV 2011 Subject to change For further information please contact us Carl Zeiss AG Camera Lens Division 73446 Oberkochen Germany cine zeiss de www zeiss com cine...