6

 

Measuring procedure  

Choose two comparison standards 
whose values are close to the expected 
retroreflection of the marking to be 
tested. Insert them into the device 
aligned on the left and right edge as 
described above. 

 

Press the light switch (1) during the 
whole visual testing procedure and 
observe the road markings to be 
tested and the comparison standards 
through the observation window (5).  

 

 

 

 

 

 

 

 

 

View through the observation window (3) 

Compare the retroreflection of 
the marking with the 
retroreflection of the 
comparison standards and 
decide if the sample has a 
higher or lower retroreflection. 
Choose further comparison 
standards and repeat the testing 
in order to receive more precise 
results. 

 

In the example at hand, the retroreflection of the marking is higher than of both 
comparison standards. In this case, two standards with values over 150 mcd . lx

-1

 . 

m

-2

, could be chosen, e.g. 175 mcd . lx-1 . m-2 and 200 mcd . lx-1 . m-2, for a 

second comparison to get preciser results. 

observation 
angle 

Measuring direction 
(observation direction) 

Summary of Contents for ZVR 6000

Page 1: ...ZVR 6000 Visual Retroreflectometer RL Instruction Manual...

Page 2: ......

Page 3: ...ard delivery 5 3 4 Options 5 4 Device overview 6 5 Inserting comparison standards 8 6 Measuring procedure 9 7 Maintenance and cleaning 10 7 1 Maintenance which can be carried out by the user 10 7 2 Cl...

Page 4: ...ost care Nevertheless errors cannot be entirely excluded The manufacturer will not be liable for errors in this instruction manual or for damages resulting from any errors The manufacturer will be gra...

Page 5: ...ee and liability claims to Zehntner GmbH Testing Instruments will be void The ZVR 6000 Visual Retroreflectometer RL is exclusively intended for the determination of night visibility of road markings u...

Page 6: ...in the following way When opening the parcel we had to notice that etc This superficial checking of the goods has to be done within the time limit set by the courier service which is normally 7 days H...

Page 7: ...type AA Additional comparison standards Ordering scheme for additional comparison standards ZZS colour glass beads retroreflection value type colour W white G yellow F_Spec with material of customer...

Page 8: ...Page 6 4 Device overview 1 light switch 2 handle 3 opening overlap 4 device cover 5 observation window 6 wheels 4 6 5 3 2 1...

Page 9: ...Page 7 battery case cover opened battery case cover light and handy easy to carry carrying handle lift to open...

Page 10: ...he accessory drawer is removable To insert the comparison standards follow these steps Remove the accessory drawer Lift the holding clip for comparison standards push the required standard underneath...

Page 11: ...he observation window 3 Compare the retroreflection of the marking with the retroreflection of the comparison standards and decide if the sample has a higher or lower retroreflection Choose further co...

Page 12: ...ds 7 3 Changing of the batteries After opening the battery case cover the provided 4 AA batteries will be seen Empty batteries can be replaced either by commercially available new batteries or by rech...

Page 13: ...ight visibility of road markings The observation angle of 2 29 corresponds to the viewing distance of a vehicle driver of 30 m under normal conditions The illumination angle is 1 24 The angle definiti...

Page 14: ...710 1 05 Illumination angle RL EN 1436 1 24 RL ASTM E1710 88 76 Test area WxL 50 mm x 160 mm 2 x 6 3 Comparison standards 50 mm x 150 mm 2 x 5 9 Testing principle according to Muench Battery 4 Alkalin...

Page 15: ...vice Cleaning 10 Delivery 4 Overview 6 E Exclusion of liability 2 Extent of delivery 5 F Features 2 M Maintenance and cleaning 10 Measuring geometry 11 Measuring principle RL 11 Measuring procedure 9...

Page 16: ...Zehntner GmbH Testing Instruments Gewerbestrasse 4 CH 4450 Sissach Switzerland Tel 41 0 61 953 05 50 Fax 41 0 61 953 05 51 zehntner zehntner com www zehntner com Version 2 3 dated 22 09 2016...

Reviews: