background image

EN - 2   

1.2 safety

1.2.1  safety regulations

Always comply with safety regulations in this man-
ual. Non-compliance with the safety regulations, 
warnings, notes and instructions in this manual can 
cause personal injury or damage to the ComfoAir.
•  The ComfoAir may only be installed, connected, 

rendered operational and maintained by an ap-
propriately approved installer, unless otherwise 
indicated in this manual;

• 

Installation of the ComfoAir must be carried out 
in accordance with the general and locally ap-
plicable construction, safety and installation 
instructions of the local council, electricity and 
water boards or other agencies;

• 

Observe the safety regulations, warnings, com-
ments and instructions as prescribed in this 
manual at all times;

• 

Keep this manual with the ComfoAir throughout 
its life;

• 

Instructions with regard to cleaning or replacing 
the filters of the intake and exhaust valves must 
be carefully observed;

• 

The specifications stated in this document may 
not be changed;

• 

Modifying the ComfoAir is not allowed;

•  The ComfoAir is only suitable for connetion to 

230V 50Hz mains;

• 

It is recommended to take out a maintenance 
contract so that the device is checked on a 
regular Basic. The supplier can provide a list of 
registered installers nearby.

1.2.2  safety provisions and measures

•  The ComfoAir cannot be opened without using 

tools;

•  It  should  not  be  possible  to  touch  the  fans, 

therefore ducting must be connected to the 
ComfoAir at a minimum duct length of 900mm.

1.2.3  Pictograms used

The following pictograms are used in this manual:

 Point of attention.

 Risk  of: 

  -  damage to the device; 

  -   performance of the device is compro-

mised if instructions are not observed 

carefully.

 

Risk of personal injury to the user or           

 installer.

Summary of Contents for ComfoAir 350

Page 1: ...I EN ComfoAir 350 User manual...

Page 2: ...has been compiled with the utmost care The publisher cannot be held liable for any damage caused as a result of missing or incorrect information in this manual In case of dis putes the Dutch version...

Page 3: ...fire programme 3 2 1 6 Wireless RF control optional 3 2 1 7 Preheater element optional 3 2 1 8 Enthalpy optional 3 2 2 Available operating devices 4 2 2 1 Display 4 2 2 2 3 position switch 4 2 2 3 Ba...

Page 4: ...EN IV...

Page 5: ...n 19th October 1998 under number 119 1998 1 1 2 Guarantee conditions The ComfoAir is covered by a manufacturer s war ranty for a period of 24 months after fitting up to a maximum of 30 months after th...

Page 6: ...the ComfoAir throughout its life Instructions with regard to cleaning or replacing the filters of the intake and exhaust valves must be carefully observed The specifications stated in this document ma...

Page 7: ...der outside air in at night the indoor temperature of the dwelling can be kept low during hot days The bypass works auto matically simply set the required comfort tempera ture 2 1 4 Frost protection T...

Page 8: ...Activation delay 3 s P22 Select 22 4 OK 30 Current setting 5 10 x or press and hold 20 Select 20 6 OK P22 Sets the value to 20 7 MENU P2 8 MENU 1 Fan setting Only in the P2 menus settings can be made...

Page 9: ...on level This switch is mostly fitted in the bathroom to extract any excess moisture after showering as soon as possible The bathroom switches vary widely in model and are therefore not illustrated he...

Page 10: ...15 Min 0 Min P22 Optional Note Only applies to systems fitted with a corded switch and a second switch in the bathroom Overrun timer for the bathroom switch to switch to normal position x minutes afte...

Page 11: ...ted with an RF switch Overrun timer for ventilation setting 3 us ing After pressing continuously 2 sec the ComfoAir will switch to the high setting for x minutes and then au tomatically returns to the...

Page 12: ...tilation system could have become dirty with building dust 2 4 2 Cleaning the valves in your dwelling The ventilation system may be fitted with the fol lowing valves Exhaust valve STB Exhaust valve ST...

Page 13: ...once more 2 5 3 What to do in the event of a malfunction In the event of a malfunction contact the installer Note down the malfunction code that appears on the digital operating device Make a note of...

Page 14: ...Company register Zwolle 05022293 EEC declaration of conformity Machine description Heat recovery units ComfoAir 350 series Complies with the following directives Machinery Directive 2006 42 EEC Low V...

Page 15: ...11 EN...

Page 16: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Zwole Nederland Tel 038 429 69 11 Fax 038 422 56 94 Internet www jestorkair nl E mail info jestorkair nl Zehnder Group Nederland B V 849050655 0711...

Reviews: