2.7.1 P menus for the user
Menu P1
¨
Status of programmes
Status
Sub-menu
Description
Activated
P11
Is menu 21 currently active?
Yes (1) / No (0)
P12
Is menu 22 currently active?
Yes (1) / No (0)
P13
Is menu 23 currently active?
Yes (1) / No (0)
P14
Is menu 24 currently active?
Yes (1) / No (0)
P15
Is menu 25 currently active?
Yes (1) / No (0)
P16
Is menu 26 currently active?
Yes (1) / No (0)
P17
Is the Summermode currently active?
Yes (1) / No (0)
Menu P2
¨
Setting time delays
Time delay values
Sub-menu
Description
Minimum
Maximum
General
Reset
P21
(Optional)
Note:
Only applies to systems
fitted with a corded switch and a
second switch in the bathroom.
Delay timer for the bathroom switch (to switch to high
position).
■
'x' minutes after operating the bathroom switch, the
ComfoAir switches to the high setting.
- Low voltage input
0 Min.
15 Min.
0 Min.
P22
(Optional)
Note:
Only applies to systems
fitted with a corded switch and a
second switch in the bathroom.
Overrun timer for the bathroom switch (to switch to normal
position).
■
'x' minutes after operating the bathroom switch, the
ComfoAir switches back to the normal setting.
- Low voltage input
0 Min.
120 Min.
30 Min.
P23
(Optional)
n/a
0 Min.
120 Min.
0 Min.
P24
Filter warning
■
'x' weeks after cleaning the filters the "filter dirty" alert
will reappear.
10 weeks
26 weeks
16 weeks
P25
n/a
1 Min.
20 Min.
10 Min.
P26
n/a
1 Min.
120 Min.
30 Min.
P27
Note:
Only applies to systems fitted with a
ComfoSense panel.
Time for the Boost setting.
■
After turning on the PARTY TIMER on the ComfoSense
panel, the ComfoAir will switch to the high setting for 'x'
minutes and then automatically returns tot the NORMAL
setting
If any 3-position switch is operated during this lagging time
the ComfoAir will instantly revert to the ventilation position
as set at that time.
0 Min.
120 Min.
30 Min.