background image

Wastewater  
lifting unit 

MICROBOY

Operating instructions

Summary of Contents for MICROBOY

Page 1: ...Wastewater lifting unit MICROBOY Operating instructions...

Page 2: ...ith safety advice 5 2 3 Safety conscious working 5 2 4 Safety information for owner operator 5 2 5 Safety information for maintenance inspection and fitting 5 2 6 Non manufacturer modification and spa...

Page 3: ...R Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld declare that the wastewater lifting unit Microboy conforms to the following specifications EMV 92 31 EWG und 93 68 EWG EG low voltage specifi...

Page 4: ...ng machines Manufacturer Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Instruction last modified January 2009 1 2 Technical data Power P1 0 65 kW Voltage U 230 V 50 Hz Nominal curre...

Page 5: ...vironmental damage resulting from leaks of environmentally dangerous substances 2 3 Safety concious work These safety instructions as well as all national safety requirements and extra internal compan...

Page 6: ...In case of a mal function the water level inside the tank will not decrease Another 30 seconds later the alarm buzzer will be activated For manual tests the pump can be started by pressing the switch...

Page 7: ...about 6 12 seconds which depends on the lifting head During this time the tank will be emptied but the pump will work for another 15 seconds additionally to clean the cutting device This time can be c...

Page 8: ...rm service control system damaged inform service motor defective inform service 2 motor turns but no pumping outlet hose clogged or buckled clean or repair testrun air vent of pump housing clogged rem...

Page 9: ...1 320 1 Pressure hose MICROBOY 117604 1 330 2 Hose clip 20 32 117033 1 340 2 O ring 34 52x3 53 117034 1 350 4 Rubber foot 117035 1 360 2 Countersunk 3 5x9 5 117605 1 370 1 Non return valve valve 11705...

Page 10: ...ssembly Switch device 3 0 1 Switching deviceMICROBOY E2 complete 117410 1 3 10 1 Switching box bonnet 117606 3 20 1 Switching box bottom section 117607 3 25 1 Circuit board MICROBOY E2 600 250 3 30 1...

Page 11: ...Appendix 1 Installation example Appendix 2 pump unit...

Page 12: ...Appendix 3 and 4 overview complete lifting unit...

Page 13: ...overdrive time 5 s delay time 5 s overdrive time 15 s delay time 5 s overdrive time 10 s delay time 0 s overdrive time 5 s delay time 5 s overdrive time 20 s delay time 5 s overdrive time 10 s delay t...

Page 14: ......

Reviews: