Zehnder Pumpen Drain Inox 50 MA Operating Instructions Manual Download Page 3

2

1. General

1.1 Application 

This operating instruction is valid for 

t

he pumps of the DRAIN-INOX 50 submersible motor pump series

Non-compliance with the operating instructions - in particular with the safety instructions - as well as non-manufacturer modification or use 
of non-original spare parts will result in loss of guarantee coverage. The manufacturer accepts no liability for damage or injury resulting from 
incorrect use of the equipment. 
These dewatering pumps are designed for delivering of well contaminated water with particulate materials from private household, industry 
and agriculture. The particle size must not exceed the mentioned size at ch. 1.3. 
This product may also pass as any other electrical equipment in cause of lacking electrical supply. If you may get any damages thereby, 
please calculate in accordance to the use an emergency power generator, a second pump and/ or a network independent alarm system. As the 
manufacturer we will be at your disposal after the buying for near information. In cause of defects or damages please contact your retail 
trader. 

Instruction last modified

: 0

9

/20

20

1.2 Queries and Ordering 

For queries and orders please contact your authorised retail trader. 

1.3 Technical data 

Typ: 

Drain Inox 50 MA

Input power P

1

 

450

 W

Voltage / frequency 

230 V / 50 Hz 

Nominal current 

2

 A

Nominal speed 

2800 U/min 

Power cable 

10 m, 3 x 1 mm² 

max. capacity 

90

00 l/h

max. head 

8

 m

max. particle size 

10 mm 

Pressure size 

G 1 

¼

“ IG

Weight 

4,0

 kg

Height over all 

270

 mm

Diameter 

1

70

 mm 

max. liquid temperature 

35 

°C (temporary

 

75

 °C)

Float switch 

yes 

Materials 

Pump body 

Stainless steel

Outer housing 

Stainless steel 

Strainer 

Stainless steel 

Motor housing 

Stainless steel 

O-rings

Float switch
Seals

NBR

PP 
Carbon/ Ceramics 

Motor shaft 

Stainless steel 

GB

B

Reviews: