7
Kickback protection:
Enable Kickback Protection
... enables, or disables kickback protection.
Lobe Length [°]
... trigger lobe length in degrees. Lobe length is used to calculate RPM at
starting. Wrong value result in wrong calculation.
Min Starting RPM
...
minimal RPM for starting.
Starting Retard [°]
...
ignition retard, only at starting.
lobe length
in degrees
Throttle Position Sensor:
TPS closed [0%]
...TPS close position must be calibrated, for correct TPS operation !
TPS opened [100%]
...TPS open position must be calibrated, for correct TPS operation!
Number of TPS points
... set number of TPS points in ignition map from 1 to 5 points.
Power Jet 1:
Power jet change state when TPS value is lower, or higher from programmed value.
Min and max revs setting also change power jet state.
TPS curve is interpolated between RPM points.
Nr. of Points
...
number of RPM and TPS points.
Invert ON/OFF
... inverting power jet operation. ON means energized power jet and OFF
means de-energized power jet.
RPM
of each point can be set from 500rpm to 20000rpm in 10rpm steps.
At the left side must
be lowest RPM value and each next point must have higher value then previous...
TPS[%]
...TPS points can be set from 0% to 100% in 1% steps.
Example of power jet operation:
Apply to above screen shoot settings...
ON means energized power jet and OFF means de-energized power jet.
PJ is OFF when TPS is higher then 50% and revs are between 3500rpm and 6500rpm.
GPO1 (General Purpose Output):
GPO can be configured as Tachometer output, or Power Jet 2.
Tachometer Output:
Tachometer signal is one pulse per revolution, square wave signal.