VCDI-04 AND VCDI-04s DIGITAL IGNITION
VCDI-04
is designed to work with original Yamaha flywheel generator pickups on aircooled
E model, LC and YPVS.
VCDI-04s
is designed to work with original Suzuki RG500 pickup.
TECHNICAL DATA
Limit values:
minimum revs
200 RPM
maximum revs
20000 RPM
minimum supply voltage
8 Volts
maximum supply voltage
20 Volts
max. supply voltage for 1 minute
40 Volts
Circuit is protected against reverse supply voltage (wrong connection).
Features:
- it is upgrade to existing ignition system
- ten custom programmable curves
- store and load function for ten custom curves
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- each curve can be set in 4 to 10 curve points
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- instant monitoring of rev's and angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
Very important!
Resistor spark plugs must be used, because they produce less electromagnetic disturbances.