zeeltronic VCDI-04 User Manual Download Page 1

 

www.zeeltronic.com 
[email protected] 
 
updated 17.07.2008 
program version: 020.180906 
 

USER MANUAL  

VCDI-04 AND VCDI-04s DIGITAL IGNITION 

 

 

 
VCDI-04

 is designed to work with original Yamaha flywheel generator pickups on aircooled 

E model, LC and YPVS. 

VCDI-04s 

is designed to work with original Suzuki RG500 pickup.

    

 
TECHNICAL DATA 
 
Limit values: 
minimum revs 

200 RPM 

maximum revs 

20000 RPM 

minimum supply voltage 

8 Volts 

maximum supply voltage 

20 Volts 

max. supply voltage for 1 minute 

40 Volts 

 
Circuit is protected against reverse supply voltage (wrong connection). 
 
Features: 
- it is upgrade to existing ignition system 
- ten custom programmable curves 
- store and load function for ten custom curves 
- easy and fast programming on the field, via hand held programmer 
- programming while machine running - you can immediately see effects 
- each curve can be set in 4 to 10 curve points 
- three stage rev limit (retard timing, reduced spark, spark off) 
- signal delay compensation  
- instant monitoring of rev's and angle, via LCD(hand held programmer) 
- fast processing for high accuracy - delays from 1us 
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...) 
 
 

Very important! 

Resistor spark plugs must be used, because they produce less electromagnetic disturbances. 
 

 
 
 

Summary of Contents for VCDI-04

Page 1: ...reverse supply voltage wrong connection Features it is upgrade to existing ignition system ten custom programmable curves store and load function for ten custom curves easy and fast programming on the...

Page 2: ...se Width output signal pulse width Pulses Per Rev number pulses per rev from pickup Exit Settings 3 LOAD SETTINGS Enter menu and move to Load Settings with pressing or and then press enter Now you can...

Page 3: ...hange NUMBER OF IGNITION CURVE POINTS Move to Nr of Points with pressing or and then press enter Now you can select number of ignition points with pressing or and then press enter 5 2 Change PARAMETER...

Page 4: ...ition curve Then measure with stroboscope lamp if mark at flywheel moving when changing revs If mark moving then you must change compensation delay Change Compensation Enter menu and move to Compensat...

Page 5: ...e Measured Static Angle 26 2deg this angle you must enter in VCDI Important Every time you dismantle stator or flywheel you must measure your Static Angle again Calculating mm to deg or vice versa Exa...

Page 6: ...is not important if motor running or not and if power supply is connected or not Important Do not use too much force when connecting or disconnecting programmer unit 13 ERROR REPORTS Two errors can be...

Page 7: ...ire in fuse box not directly to battery VCDI must be disconnected from power supply with moving ignition switch to off position VCDI wont work if your battery voltage is below 8 Volts Very important R...

Page 8: ...RZ350YPVS Important VCDI must be disconnected from power supply with moving ignition switch to off position VCDI wont work if your battery voltage is below 8 Volts...