background image

Start of Configuration

RESET

 The reading of the "RESET” label

turns all the parameters back to
default values.

 

When you intend to turn your

scanner back to default
parameter, please scan the
"Start of configuration" label first,
then scan "RESET" label 

and

finally scan the "End of
configuration" label.

ABORT

RS-232C

PC/AT

WAND EMULATION

SHOW VERSION

 The reading of the "ABORT" label

discards all the parameters read

prior to the "End of

configuration".

 The scanner remains in the last

interface mode when the

scanner is reset.  The label

below should be scanned if the

scanner is configured the first

time.

 The reading of the “ SHOW

VERSION”  label will be show

firmware version.

SCANNING MODE SELECTION(for laser scanner)

For series laser scanners, there are 3 scanning modes to
suit your application requirements.

Trigger Mode

Turbo Trigger Mode

The scanner becomes inactive as
soon as the data is transmitted.  It
must be triggered to become active
again.
The scanner switch is pressed and
double reading for the same bar
code is permitted.  The scanner
will turn off when the trigger switch
is released.

6

Without any scanning, the unit will
enter a standby mode.  To
reactivate the unit, present an
object in front of the IR sensor.
(*Only for Alpha-60 series.)

Object detect Trigger

Note: To avoid hazardous exposure, all laser scanner are 

equipped with an internal cut-off security system 
which will turn off the laser beam after 5 seconds.

SCANNING MODE SELECTION (For Alpha-70
series)

The scanner becomes inactive as
soon as the data is transmitted.  It
must be triggered to become active
again.

In auto scan mode, the scanner is
still active after the data is
transmitted, but the successive
transmission of the same bar code
is not allowed when the trigger
switch is pressed again.

This scanner will light up when
press the scanner trigger switch
once.  And, the scanner will turn
off for next pressing.

For testing the response of the
scanner.

For factory testing use only.

Trigger mode

Auto scan mode

Alternate mode

Repeat mode

Testing mode

DATA REDUNDANT CHECK

The option allow you to set decoder
data redundant check.

Enable

Disable

End of Configuration

7

Summary of Contents for Alpha-50 series

Page 1: ...ZBX99030301 P N MUL 53221 04 DO NOT STARE INTO BEAM LASER LIGHT CAUTION 670nm LASER DIODE 1 0mW MAX OUTPUT IEC 825 1 1993 CLASS I US 21 CFR 1040 CLASS IIa LASER PRODUCT...

Page 2: ...y Taipei Taiwan R O C Tel 886 2 2218 2018 Fax 886 2 2218 8670 Web site www zebex com tw E mail mail zebex com tw ZEBEX INDUSTRIES INC Auto ID Division 1F 531 Chung Cheng Road Hsin Tien City Taipei Tai...

Page 3: ...Machines Corp IBM PS 2 is a product of International Business Machines Corp NEC is a registered trade mark of NEC Corporation All other registered trade marks are registered companys property ZEBEX i...

Page 4: ...per Tone Selection 10 Bar Code ID Selection 11 RS 232C Serial Communication Parameters Setting Handshaking Protocol 13 ACK NAK Response Time Setting 14 Baud Rate 15 Data Bit 15 Stop Bit 15 Parity Sett...

Page 5: ...to the scanner If a keyboard emulation type scanner is used with a IBM PC XT AT PS 2 or any fully compatible computers power will be drawn from the keyboard port No external power adapter is required...

Page 6: ...UPC E bar code identifier code E UPC A bar code identifier code A EAN 13 bar code identifier code F EAN 8 bar code identifier code FF Codabar bar code identifier code N Code 128 bar code identifier c...

Page 7: ...it Disable Chinese Post Length 10 16 digits Code Check digit Transmit Format All Addendum Disable UPC E UPC A Disabled UPC EAN JAN UPC A leading digit Transmit UPC A check digit Transmit UPC E leading...

Page 8: ...sed and double reading for the same bar code is permitted The scanner will turn off when the trigger switch is released 6 Without any scanning the unit will enter a standby mode To reactivate the unit...

Page 9: ...cutive messages This delay will be added before each data transmission Start of Configuration label and then select the appropriate delay time to activate this feature None 100mSec 500 mSec 1 Second 8...

Page 10: ...e buzzer after successful reading Medium Low High Disable For Alpha 70 only Medium and disable setting available 10 SOUND DURATION long 120ms Medium 50ms Short 20ms Very short 5ms BAR CODE IDENTIFIER...

Page 11: ...nfiguration label 2 Scan Bar code identifier setting code label 3 Scan the new code mark from ASCII table max two digits For example if AB want for code mark then scan A and B 4 Scan Set label 5 Scan...

Page 12: ...ration HANDSHAKING PROTOCOL Cont d ACK NAK Xon Xoff ACK NAK RESPONSE TIME SETTING 300 mSec 2 Sec 500 mSec 3 Sec 1 Sec 5 Sec 14 BUAD RATE 19200 9600 4800 2400 1200 600 DATA BIT 7 8 STOP BIT 1 2 End of...

Page 13: ...ESSAGE TERMINATOR FOR RS 232C TYPE ONLY None CR LF CR LF H Tab 16 STX ETX EOT KEYBOARD EMULATION PARAMETERS SETTING KEYBOARD TYPE SELECTION IBM AT PS 2 30 80 IBM 5550 IBM 5295 Terminal IBM XT IBM 3477...

Page 14: ...9801 IBM 3196 Terminal APPLE MAC II MOS SYS PS2 30 56 IBM 3477 Terminal without break code NEC 5200 Note The configuration of the items with asterisk is optional 18 KEYBOARD LANGUAGE SELECTION USA UK...

Page 15: ...erface for these IBM terminal read the correct key transmission code ON OFF 20 FUNTION KEY ACTIVE ON OFF FOR IBM AT USE Function keys can be concatenated with input data as header and or trailer See p...

Page 16: ...2 of 5 Disable Chinese post code Enable Chinese post code Disable Code 128 Enable Code 128 Disable MSI Enable MSI Disable 22 Code 93 Enable Code 93 Disable IATA Enable IATA Disable EAN 128 Enable EAN...

Page 17: ...GIT Calculate and Transmit Calculate but not Transmit NO CONCATENATION Enable Disable 24 INTERLEAVED 2 OF 5 PARAMENTERS SETTING Examples Felting length 4 to 8 digits LENTGTH Ssan 1 Start of configurat...

Page 18: ...f configuration Min 0 4 set max 0 8 set End of configuration CHECK DIGIT NO Calculate and Transmit Calculate but not Transmit UPC EAN JAN PARAMETERS SETTING FORMAT All 26 EAN 8 or EAN 13 UPC A and EAN...

Page 19: ...cters FORCE UPC E TO UPC A FORMAT Yes No FORCE UPC A TO EAN 13 FORMAT Yes No TRANSMIT UPC A LEADING CHARACTER Yes No 28 TRANSMIT UPC A CHECK DIGIT Yes No TRANSMIT UPC E LEADING CHARACTER Yes No TRANSM...

Page 20: ...ON No A B C D DC1 DC4 a t b n c d e CONCATENATION Enable Disable 30 CODE 128 PARAMETERS SETTING FNC 2 CONCATENATION Enable Disable CHECK DIGIT No Calculate and Transmit Calculate but not Transmit UCC...

Page 21: ...x 0 8 set End of configuration Double Check digit Calculate but not Transmitted No 32 MSI PLESSY PARAMETERS SETTING Cont d Calculate but only first one Transmitted Calculated and both Transmitted Sing...

Page 22: ...G CODE 39 LENGTH SETTING MAX MIN CODE 93 LENGTH SETTING MAX MIN 34 CODE 128 LENGTH SETTING MAX MIN Set CODABAR LENGTH SETTING MAX MIN ISBN ISSN CONVERSION The function convents the UPC EAN codes appea...

Page 23: ...G EMULATION SPEED SELECTION Low Medium Normal High Higher EMULATION DATA OUTPUT SELECTION The decoded data output logic level can be set to befit the external decoder Black High Black Low 36 WNAD EMUL...

Page 24: ...N X 18 H 3D EM Y 19 I 3E SUB Z 1A J 3F ESC A 1B V 40 FS B 1C A A 41 GS C 1D B B 42 RS D 1E C C 43 US E 1F D D 44 SP SP 20 E E 45 A 21 F F 46 B 22 G G 47 C 23 H H 48 D 24 I I 49 38 APPENDIX A CODE 39 F...

Page 25: ...W 17 Backspace H 08 F8 X 18 TAB I 09 F9 Y 19 Enter num J 0A F10 Z 1A Right K 0B F11 A 1B PgUp L 0C F12 B 1C Enter M 0D ESC C 1D PgDn N 0E Ctl L D 1E shift O 0F Alt L E 1F 5 num P 10 CURSOR PAD WORK AT...

Page 26: ...uration LF Enter num DLE 5 num VT Right DC1 F1 FF PgUp DC2 F2 CR Enter DC3 F3 SO PgDn DC4 F4 SI shift L NAK F5 42 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE SYN F6 GS ESC ETB F7 RS Ctl L CAN F8 US A...

Page 27: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration 0 1 44 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE 2 3 4 5 6 7 8 9 A End of Configuration 45...

Page 28: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration B I C J D K E L F M G N H O 46 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE P W Q X R Y S Z T U V End of Configuration 47...

Page 29: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration e _ f g a h b i c j d k 48 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE l s m t n u o v p w q x r y End of Configuration 49...

Page 30: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration z DEL End of Configuration 50...

Reviews: